3 MV Tandetron based FRENA - PowerPoint PPT Presentation

1 / 42
About This Presentation
Title:

3 MV Tandetron based FRENA

Description:

3 MV Tandetron based FRENA – PowerPoint PPT presentation

Number of Views:199
Avg rating:3.0/5.0
Slides: 43
Provided by: ho90
Category:
Tags: frena | based | jow | koto | tandetron

less

Transcript and Presenter's Notes

Title: 3 MV Tandetron based FRENA


1
3 MV Tandetron based FRENA
FRENA Facility for Research in Nuclear
Astrophysics SAHA INSTITUTE OF NUCLEAR
PHYSICS February 19, 2008
2
Outline
  • HVE Product range
  • HVE Installed base
  • HVE Tandetrons
  • Features
  • Performance
  • 3 MV Tandetron based FRENA
  • System Characteristics
  • System Layout
  • System performance

3
Product range
  • Ion accelerator systems
  • Air insulated up to 500 kV
  • Singletron single-ended accelerators up to incl.
    6.0 MV/TV
  • Tandetron tandem accelerators up to incl. 6.0
    MV/TV
  • Ion implanters
  • Beam energies 10 keV 60 MeV and higher
  • Beam power up to 25 kW
  • Electron accelerators
  • Beam energies up to 6.0 MeV
  • Beam power up to 50 kW

4
Product range
  • Systems for Ion Beam Analysis
  • Rutherford Backscattering Spectroscopy (RBS)
  • Particle Induced X-ray Emission (PIXE)
  • Nuclear Reaction Analysis (NRA)
  • Elastic Recoil Detection (ERD)
  • Medium Energy Ion-scattering Spectroscopy (MEIS)
  • Accelerator Mass Spectrometers (AMS)
  • Systems for Nano- and Micro-beam applications
  • Neutron generators
  • DC and Pulsed beam systems

5
Installed base
  • HVE installed base
  • Research Market
  • Worldwide over 500 systems sold
  • Americas over 200 systems sold
  • Europe over 240 systems sold
  • Far East over 50 systems sold
  • Industrial Market
  • Worldwide over 100 systems sold

6
Installed base
3.0 MV T-Shape Tandetron accelerator system for
IBA / IBMPorte Allegre, Brazil
7
Installed base
5.0 MV Coaxial High Current Tandetron for IBA /
IBMUAM Madrid, Spain
8
Installed base
3.5 MV In-line Singletron for nano-probe
applicationsGradignan, France
9
Installed base
3.5 MV Coaxial Singletron for IBACatania, Italy
10
Installed base
1.0 MV multi-element AMS systemCNA, Sevilla,
Spain
11
Installed base
5.0 MV multi-element AMS systemAix-en-Provence,
France
12
Installed base
500 kV Air insulated acceleratorKunming, China
13
Installed base
1.25 MV Coaxial High Current TandetronHamilton,
Canada
14
Installed base
1.25 MV Coaxila High Current Tandetron based Ion
ImplanterIndustry (Confidential) Reliabilty and
up-time are key requirements
15
Tandetron - Features
  • Accelerator tubes

16
Tandetron - Features
  • Unique all-solid-state HV power supply

17
Tandetron FeaturesHV Power supplyClose match
between Design Performance
Measurement of the coupling factor
18
Tandetron Control System
  • Computer control system
  • Hardware
  • Industrial PC type computer interfaced via fibre
    optic isolated
  • Control Area Network (CAN) to local micro
    controllers
  • Software
  • Operating system Microsoft Windows XP
  • Program language C-Sharp

19
Tandetron Software Features
  • User interface

20
Tandetron Software Features
  • Magnet calculation Automatic setting of magnet
  • current on entry of desired ion mass, charge
    state
  • and, where applicable, magnet exit port

21
Tandetron Software Features
  • System diagnostics
  • Logging Continuous logging of all I/Os
  • Trending Continuous trending of up to 5 readouts
    as
  • a function of time

22
Tandetron Software Features
  • Tracing Display of up to 5 readouts as a
    function of
  • a scan of 1 specific analog
    control

23
Tandetron Software Features
  • Mapping Display of 1 parameter during a two
    dimensional scan of 2 independent
    controls e.g
  • Beam current in Q-snout Faraday cup as a
    function
  • of injector Einzellens and magnet
    parameters

24
Tandetron Software Features
  • Beam monitoring Computer screen display of
  • Beam profiles in X and Y
  • Beam cross section with beam intensity
    distribution

25
Tandetron Software Features
  • Vacuum system Control and status overview of
  • valves, pumps and vacuum levels

26
Tandetron Software Features
  • System interlocking
  • Potentially dangerous user actions are hindered
  • Automatically appearing dialog boxes upon
    interlock
  • triggering
  • Passport protected interlock overriding
  • System automatically put to save mode after
    electric
  • power failure

27
Tandetron PerformanceBeam power capability25
kW all-solid-state RF driver
All-solid-state RF driver connected to a 2.0 MV
Tandetron with a bank of heating elements in
series dissipating a total of 28 kW.
  • Features
  • All-solid-state design
  • Fast transient response
  • Low ripple and high stability (10-5 range)
  • Soft-switching topology for 96 efficiency

28
Tandetron PerformanceBeam power and
definition F-cup failure
0.5mm Ta brazed on 16mm cooled Cu
800µA H at 4MeV within 1mm2 ? Melted Tantalum
(gt3300K) !! Average brightnes 22 pA/ µm2 mr2
MeV ! (half angle 3mrad) Core brightness
100 pA/ µm2 mr2 MeV !?!
29
Tandetron PerformanceTerminal Voltage Ripple
(3.5 MV Singletron)
30
Tandetron PerformanceTerminal voltage ripple
(5 MV Tandetron)
Terminal voltage ripple
  • TV 100 - 800 kV lt10 VRMS .
  • TV 800 - 5000 kV lt 10-5 (RMS).

31
Tandetron PerformanceTransient response (5 MV
Tandetron)
  • Prompt injection of Si- at 3 MV, total beam load
    gt 1 kW
  • Maximum terminal undershoot of 4.2 kV or 1.4 .
  • Recovery within 50 ms to within 0.3 of the set
    value
  • after a prompt injection of 1 kW beam.

32
Tandetron PerformanceTransient response (2 MV
Tandetron)
  • Prompt injection of 0.9 mA H- at 2 MV, total beam
    load gt 3.5kW
  • Maximum terminal voltage undershoot of 10 kV
    or 5 .
  • Recovery within 60 ms to within 0.5 of the set
    value
  • after a prompt injection of 4 kW beam.

33
Tandetron PerformanceEnergy stability (3.5 MV
Singletron)Measured using Li(p,n) reaction at
1.881 MeV
Estimated stability /- 50eV over 5h, but
anticipated to be as good as /- 20eV (i.e.
10-5) observing the period 0.5 lt t lt 3.5h.
34
3 MV Tandetron based FRENA Overall System
Characteristics
  • Wide energy range
  • High currents of Light and heavy ions
  • Extreme high stability and energy resolution
  • Continuous operation
  • Pulsed beam applications
  • Dedicated software
  • to cope with high-power (gt2 kW) ion beams

35
Layout Overall System
36
Layout - Heavy ion Injector
  • Ion source body at
  • ground potential
  • 50 (200) samples
  • in one carousel load
  • Unattented operation
  • Small emittance for
  • high transmission
  • at low energy
  • Provisions for
  • future extension for
  • heavy-ion bunching

Heavy ion sputter source model SO-110
37
Layout - Light Ion Injector
  • Dual source injector
  • Multicusp for H D
  • with direct negative extraction
  • ( 700 uA H-)
  • Multicusp for He
  • with Lithium Charge Exchange
  • ( 10 mA He ? 100 uA He-)
  • Patented Chopper-Buncher system

Single source injector with SO-120 Multicusp ion
source
38
Layout - Multi-deflector Chopper Pulsed neutron
facility, CEA Cadarache, France
39
Layout - Multi-deflector Chopper US patent
7,244,952
  • Characteristics
  • 1st and 2nd corrector steerer units
  • Features
  • DE dominated by Ion source (5-10eV)
  • Beam intensity modulation only
  • Beam stable in angle and position
  • Reduced effective beam size
  • (increases system transmission)

40
Performance - Multi-deflector Chopper Pulsed
neutron facility, CEA Cadarache, France
Beam current at target (A.U.)
Time in ns
Rise time 10 ns Flat top injection
41
Performance - Pulsed Beam Operation Pulsed
neutron facility, CEA Cadarache, France
  • Pulse width at target for 2 MeV H
  • Measurement resolution 300 ps
  • Measured FWHM 810 ps 630 ps because
    of M4 hole?
  • Estimated Pulse-width 550 ps
  • Note Pulse is free of timing tails!

42
Performance - Overall System
  • Beam current at target
  • H 350 500 uA at 6 MeV (gt 2 kW beam power)
  • He2 50 100 uA at 9 MeV
  • Usable terminal voltage range 200 3000 kV
  • Terminal voltage stability 80 V at 2 MeV
  • Pulse repetition frequency adjustable up to 4
    MHz
  • Pulse width at target 1-2 ns

Thank you For your attention