4Very High Pressure Hydrogen Storage
- The Fuel cell vehicles (FCV) currently in trial
use are mounted with hydrogen containers
pressurized up to 400 bar and yield a driving
range of 300-350 km per filling - roughly half of
the gasoline vehicles driving range. - Industry is developing containers for up to 700
bar pressurization. - Need to gain insight of such release and its
potential for ignition
5Schematic diagram of free jet flow shock structure
6Two Modelling Approaches
- Pseudo-source approach (Ewan and Modie 1985)
- Leak modelled from downstream as a sonic jet with
the same mass flow rate
- Numerically solving the under-expanded shock
structure - Results used as inflow for the subsequent large
eddy simulation of the jet
7Simulation of the Under-expanded Shock Structure
- Commercial code CFX
- Total energy model take into the kinetic energy
of high speed flows - The k-? based shear stress turbulence (SST)
model - A TVD type high resolution discretisation scheme
to represent sharp gradients without numerical
oscillations - A global 2nd accuracy, which switches to a 1st
order upwind scheme locally to prevent
non-physical oscillations - The 2nd order backward Euler scheme to define the
discretisation algorithm for the transient term.
Validation of the code for supersonic application
is available through CFX Vendor, now part ANSYS
Europe
8Simulation of the free hydrogen jet
- KIVA-LES (modified for LES from KIVA-3V)
- Finite volume based ALE (Arbitrary
Lagrangian-Eulerian) method - the 2nd order Crank-Nicolson scheme for the
diffusion terms and the terms associated with
pressure wave propagation - The 2nd order MacCormack method for the
convective terms in the rezone phase - A 2nd order centred scheme for the convection
term in the momentum equation. - 17.
- B B P Xu, J X Wen, S Dembele, Large eddy
simulation of plane impinging jets, submitted to
Physics of Fluids. - 18. B P Xu and J X Wen, Validation of a new
droplet collision model in LES of non-evaporating
diesel fuel sprays, submitted to Int. J of
Multiphase Flow.
9Real Gas Property
- Abel-Noble EOS (Equation of State)
For hydrogen, b1.5510-5 (m3/mole), valid for
Plt1600atm and 200ltTlt 350K
This EoS has been reported to reproduce a large
part of the experiment thermodynamic data on
hydrogen within 0.1 and practically all data
within 0.5.
10Comparison of density as a function of pressure
for constant temperatures
11Choked Flow Nozzle Dynamics
- Table 1. Initial data in the high-pressure jet
simulation
- Assuming isentropic flow
- T from Van der Waals EoS
12530
K Mohamed and M Paraschivoiu, Real gas simulation
of hydrogen release from a high-pressure chamber,
Int J of Hydrogen Energy, 30 (2005).
13 14- At very high pressure ratios (such as the
previous one), only one Mach disk - Several Mach disks at relatively lower pressure
ratios
15Predicted pressure, velocity, temperature and
hydrogen mass concentrations at the centreline
16(No Transcript)
17The free hydrogen jet (with KIVA-LES)
Instantaneous density
Mean velocity
18Normalized values of main axial velocity, axial
turbulent intensity and hydrogen mass fraction
on the centreline
Normalized values of main axial velocity and
hydrogen mass density versus distance to the
centreline at different Z positions.
19(No Transcript)
20Conclusion
- The predicted flow pattern and Mach number
distribution within the shock structure are in
line with previous experimental observation and
theoretical analysis. - Apparent air entrainment is found after these
shock structures, implying that the widely used
pseudo-source approach may incur some errors for
such jet simulations. - The hydrogen release temperature is lower than
the vessel temperature when the container
pressure is below a certain value (e.g. 530 bar
in the current configuration). The situation is
different for higher vessel pressures. - A combustible cloud could be formed above the
leak source within a very short period of time
(about 0.1s).
21ACKNOWLEDGEMENT
- We gratefully acknowledge the helpful discussion
with Vincent Tam, Peter Cumber and Marius
Paraschvoiu. - Jet flame simulation is already ongoing
- Work will continue jointly with BP and HSL
through the EC funded HYFIRE project in several
areas concerning fire and explosion safety of
hydrogen.
FUTURE WORK