HANDLING ENVIRONMENTAL ISSUES IN THE NEW MILLENNIUM - PowerPoint PPT Presentation

1 / 23
About This Presentation
Title:

HANDLING ENVIRONMENTAL ISSUES IN THE NEW MILLENNIUM

Description:

PA WORKER AND COMMUNITY RIGHT TO KNOW AKA PENNSAFE. AIR ... LOOK FOR FRIABLE AND NONFRIABLE ACBM. SIGNS OF WEAR, DAMAGE, WATER DAMAGE. BLACKBOARD MASTIC ... – PowerPoint PPT presentation

Number of Views:26
Avg rating:3.0/5.0
Slides: 24
Provided by: boblip
Category:

less

Transcript and Presenter's Notes

Title: HANDLING ENVIRONMENTAL ISSUES IN THE NEW MILLENNIUM


1
HANDLING ENVIRONMENTAL ISSUES IN THE NEW
MILLENNIUM
  • PRESENTED BY
  • ENVIRONMENTAL CONTROL SYSTEMS, INC.
  • BROOMALL, PA
  • 610-328-2880
  • BOOTH 718
  • MIKE BEDNAR BARB LIPPMANN

2
PA WASTE
  • PA WORKER AND COMMUNITY RIGHT TO KNOW AKA
    PENNSAFE
  • AIR QUALITY
  • WASTE LAB PACKS/RED BAG
  • ASBESTOS
  • SPCC PLAN
  • TANKS
  • ENVIRONMENTAL ISSUES

3
PENNSAFE
  • INFORMS EMPLOYEES ABOUT HAZARDOUS SUBSTANCES
    PRESENT
  • COMPLETE HAZARDOUS SUBSTANCE SURVEY FORM BY APRIL
    1, 2007
  • LIST HAZARDOUS SUBSTANCES AT THE WORKPLACE DURING
    JANUARY 1, 2006 THROUGH DECEMBER 31, 2006

4
Hazardous Substance Survey Form
5
PENNSAFE REQUIREMENTS
  • POST A LISTING OF EMPLOYEE RIGHTS
  • LABEL ALL CHEMICAL MIXTURES
  • PROVIDE ANNUAL TRAINING
  • MAKE HEALTH EXPOSURE RECORDS AVAILABLE
  • COMPLETE HSSF AND POST BY APRIL 1

6
INDOOR AIR QUALITY
  • MOLD PROBLEMS
  • ROOF LEAKS
  • STAINED CEILING TILES
  • WET CARPET
  • HVAC DUCTS

7
AIR QUALITY SUMMER PREVENTIVE MAINTENANCE PROGRAM
  • VISUAL INSPECTION LOOK FOR LEAKS IN ROOF,
    STAINED CEILING TILES, WET CARPET, AREAS WHERE
    WATER COLLECTS
  • PROVIDE A WELL VENTILATED BUILDING WHEN CLEANING
    CARPETS
  • REGULAR FILTER CHANGE OUTS

8
AIR QUALITY SUMMER PREVENTIVE MAINTENANCE PROGRAM
CONT
  • INSPECT WINDOWS FOR MOISTURE AND MAKE NECESASARY
    REPAIRS
  • CHANGE MICRO-FILTRATION VACUUM BAGS
  • FIX LEAKY ROOFS AND FAUCETS
  • VACUUM HVAC DUCTS AND GRILLS
  • ADEQUATE VENTILATION DURING CLEANING

9
INDOOR AIR QUALITY PROBLEMS
  • PA MOLD MANAGEMENT TASK FORCE
  • CURRENTLY NO GUIDELINES
  • TEST FOR PARTICLES SUSPENDED IN AIR, DUST OR
    GROWING ON SURFACES
  • PERFORM TEST AFTER CLEAN-UP BY QUALIFIED
    ENVIRONMENTAL COMPANY

10
WASTE - CHEMICAL STORAGE
  • STORE FLAMMABLES IN LOCKED, FIREPROOF CABINET
  • STORE IN ORIGINAL SHIPPING PACKAGE
  • WELL VENTILATED STORAGE AREA
  • SAVE TIME AND OBTAIN MSDS UPON DELIVERY AND
    UPDATE HSSF AND MSDS BOOK AS SOON AS POSSIBLE

11
WASTE CHEMICAL DISPOSAL
  • DISPOSAL OF CERTAIN WASTES GOVERNED BY CERCLA
    RCRA
  • SLIGHTLY CLOUDY LIQUIDS
  • CHEMICALS THAT ARE CHANGING COLOR
  • CAKING OF ANHYDROUS MATERIALS
  • EVIDENCE OF REACTION WITH WATER
  • DAMAGE TO CONTAINER

12
INFECTIOUS WASTE RED BAG
  • Regulated waste liquid or semi-liquid blood or
    other potentially infectious materials
    contaminated items that would release blood or
    other potentially infectious materials in a
    liquid or semi-liquid state if compressed items
    caked with dried blood contaminated sharps
    pathological and microbiological wastes
    containing blood or other potentially infectious
    materials.

13
WHAT SHOULD GO IN THE RED BAG?
  • Presence of blood or other potentially infectious
    materials on item or surface
  • Other potentially infectious materials human
    body fluids, saliva in dental procedures, any
    body fluid visibly contaminated with blood other
    materials as identified by PADEP and the USEPA

14
GUIDELINES FOR STORAGE OF INFECTIOUS WASTE
  • INFECTIOUS WASTE, EXCLUDING USED SHARPS MAY BE
    STORED AT ROOM TEMP OR REFRIGERATED FOR 30 DAYS
  • MAY BE FROZEN FOR UP TO 90 DAYS
  • DECAYED WASTE SHALL BE MOVED OFFSITE WITHIN 24
    HOURS

15
ASBESTOS
  • SUMMER INSPECTION
  • LOOK FOR FRIABLE AND NONFRIABLE ACBM
  • SIGNS OF WEAR, DAMAGE, WATER DAMAGE
  • BLACKBOARD MASTIC
  • SUSPECT? COLLECT BULK SAMPLE

16
SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
  • REVISED RULE AMEND AND IMPLEMENT PLAN BY
    OCTOBER 31, 2007
  • REVIEW PLAN EVERY 5 YEARS
  • CERTIFY TECHNICAL AMENDMENTS BY P.E.
  • RAISES THRESHOLD FOR SUMBITTING SPILL REPORTS
    FROM 2 DISCHARGES GREATER THAN 42 GALLONS EACH

17
SPCC CONTINUED
  • OWNER/OPERATOR MUST CONDUCT PERIODIC INTEGRITY
    TESTING OF CONTAINERS INCLUDING PIPING
  • PLAN MUST ADDRESS DISCHARGE, DISCOVERY, RESPONSE
    AND CLEANUP AS WELL AS CONTINGENCY PRODEDURES

18
SPCC CONTINUED
  • EXEMPTS BURIED TANKS SUBJECT TO 40 CFR PART 280
    AND 281
  • DE MINIMIS CONTAINER SIZE OF 55 GALLONS
  • AST STORAGE CAPACITY THRESHOLD OF GREATER THAN
    1,320 GALLONS
  • DOES NOT APPLY TO EXCLUSIVE WASTEWATER TREATMENT
    FACILITIES

19
STORAGE TANK REGULATIONS
  • REQUIRES 3RD PARTY INSPECTIONS OF REGULATED TANKS
  • FACILITY INSPECTIONS EVERY 5 YEARS
  • EVERY 10 YEARS IF YOUR TANK SYSTEM HAS TOTAL
    SECONDARY CONTAINMENT
  • TANK LINING EVALUATION 10 YEARS AFTER
    INSTALLATION AND 5 YEAR INTERVAL THEREAFTER

20
STORAGE TANK REGS CONT
  • TANK LINING EVALUATION INCLUDES MANUAL TANK
    ENTRY, INTERNAL EXAMINATION OF TANK LINING
  • PERFORMED BY DEP CERTIFIED STORAGE TANK LINER
    (TL) OR P.E. KNOWLEDGEABLE IN TANK LINING

21
STORAGE TANKS CONT
  • PUMP AND PLUG PROGRAM
  • DEP GRANT FOR PUMPING AND DISPOSING REGULATED
    PRODUCT TO TAKE TANK OUT OF SERVICE
  • GRANT NOT TO EXCEED 2,500.00 PER TANK.
    REIMBURSEMENT TO 7-1-98
  • CONTACT DEP AT 1-800- 42-TANKS FOR INFO

22
OTHER ENVIRONMENTAL ISSUES
  • LEAD PAINT
  • LEAD IN DRINKING WATER
  • RADON
  • COMPUTER/PRINTERS/MONITORS
  • HYDROGEOLOGICAL/SUBSURFACE INVESTIGATIONS

23
THANK YOU FOR YOUR TIME. VISIT US IN BOOTH 718
Write a Comment
User Comments (0)
About PowerShow.com