Title: Voltech PM6000 Universal Power Analyzer
1Voltech PM6000Universal Power Analyzer
2PM6000
- Up to 6 wattmeter channels
- Accuracy 0.02 of reading, 0.05 of range
- Bandwidth 10MHz
- Sampling rate 40 MSPS
- Display Bright color VGA
- Connectivity RS232, IEEE488, Printer, Ethernet
- Connectivity (Future Release) PCMCIA for analog
I/O including torque and speed, USB
3PM6000 Block Diagram
Display, Keys
PC
PCI
BRG
Interfaces RS232, Ethernet
CPU CARD
BACKPLANE
PCI
Measure Channel 1 V, I
PCI
Measure Channel 2 V, I
Measure Channel 3 V, I
Measure Channel 4 V, I
Measure Channel 5 V, I
Measure Channel 6 V, I
4PM6000 Measuring Channels
- 1 to 6 channels
- Each channel a fully independent, isolated
wattmeter. - Voltage 2000Vpk
- Current 2.5Vpk
- Range of current transducers, including Voltech
30A and 1A shunts.
5PM6000 Measuring Channel
- Built on 15 years of Voltech analog know-how
- Unrivalled accuracy and bandwidth combination
- Layout and timing minimise phase delay for best
Watts accuracy
- PCI Bus
- Continuous 5 MSPS data from every channel.
- No analysis gaps, no missing data
- A- D Convertor
- 14-bit
- 40MSPS Max
- 5MSPS Min
5V
i
DSP 200MHz
v
- Isolation
- 4kVpk
- CMRR
- 140dB _at_ 60Hz
- 95dB _at_ 1MHz
- Pulse Transformers
- Data and control.
- Provide superior CMRR than opto-isolators
12V
6PM6000 Shunts
- 30Arms 250ApkFor general measurements.
- 1Arms 5ApkIdeal for low power measurements and
CTs with a 1A output. - Plug in directly to PM6000 measurement channel
- Calibration stored in EEPROM is used by the
channel to provide optimum overall accuracy. - 4mm safety sockets
- 2.5Vpk input on the measurement channel suitable
for a wide variety of current tranducers Hall
effect, Rogowski coil and active CTs with a
voltage output.
7PM6000 Connectivity
- Universal ac input 90-264V
- VGAIdeal for training and presentation
- Printer
- RS232Complete control, setup and data
acquisition - Ethernet
- PCMCIA analog I/O including torque and speed
- External trigger
- USB (Future release)
- IEEE488 (Future release)
8PM6000 Front Panel
Step by-step set-up keys
Bright VGA Display
Menu soft-keys and rotary control
Floppy Drive
Print, Display Hold and trigger function keys
Numeric entry keypad
9PM6000 Menu
- 6 soft-keys plus rotary control
Up and down the list or use the rotary knob
Select item ?or ?
Rotate group
Up menu
Down menu
10PM6000 Menu - Measurements
W Real or True Power in WattsVrms True rms
Voltage Arms True rms Amps Freq Frequency VA
Apparent Power VAr Reactive Volt-Amperes f Fund
amental or 1st harmonic Harm Harmonics of power,
volts and ampsTHD Total Harmonic Distortion
(with options for different formulae) Pk Voltage
and current peak CF Voltage and current crest
factor. (pk / rms)Z Impedance Vrmn Rectified
mean voltage Armn Rectified mean current Max /
Min Holds Maximum and Minimum values. Ideal for
Inrush testing Math The math
menu can be used to calculate efficiency from
channel to channel or to make complex
calculations such as transformer k
factors. IntegratorFor W-h consumption of
electrical appliances and low-power standby
measurements.
11PM6000 - Measurements
12PM6000 - Measurements
13PM6000 - Measurements
14PM6000 Measurement Display
- Full screen or split screen (shown here)
- Channels in columns
- Measurements in rows
Up and down the list or use the rotary knob
Left and right across the channels
Help context sensitive setup information
Access the menu
15PM6000 Power Supplies
- Up to six channels configurable as required, for
example ac input plus 5 dc outputs or three-phase
input and output. - Excellent 0.02 basic accuracy - useful for high
efficiency measurements - Accurate on all waveforms
- Samples continuously, without gaps at 5 MSPS so
there is no missing data during integration or
low-power standby measurements.
16PM6000 - Lighting
- Up to six channels configurable as required.
Single channel input and five channels in the
example above. - Excellent 0.02 basic accuracy - useful for high
efficiency measurements - 10MHz bandwidth captures all the line frequency
and high-frequency data for the most accurate
overall power measurement. - High rejection of common-mode signals found on
the ballast output. - Special ballast mode locks the analyzer to the
line frequency to provide stable and reliable
full-bandwidth data. - Easy to set up - no need to set filters or sample
rate. All done automatically in Ballast mode.
17PM6000 Power Transformers
- Up to six channels for simultaneous three-phase
input and output Star or Wye connection. - Accurate at low power factors.
- Simultaneous measurement of rms and mean voltage
as required by IEC76 and IEEEC57 - Measure turns ratio directly using the math
function.
18PM6000 Motors Drives
- Up to six channels configurable as required, for
example 3 wattmeter, three-phase input, dc bus
and two-wattmeter drive output and torque and
speed measured simultaneously - Excellent 0.02 basic accuracy - useful for high
efficiency measurements - 10MHz bandwidth captures all motor frequency and
high-frequency data for the most accurate overall
power measurement. - High rejection of common-mode signals found on
the drive output. - Special PWM mode locks the analyzer to the motor
frequency from 0.1 Hz upwards to provide stable
and reliable full-bandwidth data
19PM6000 W-h and Low Power Standby
W Input power.W-h Power integrated over
programmable time.Vrms Drop-out voltage, testing
power fail circuitsArms Conductor and fuse
rating A-h For battery back-up charge and
dischargeVA Apparent power for supply
rating VA-h Apparent power integrated over
programmable time. Apk MAX Inrush Current.
Verification of inrush limiting circuit design.
Fuse ratingPF Power Factor (W/ VA) for
verification of power factor control circuits A
harm Amps harmonics for testing to IEC and other
harmonic standards. (Full IEC61000-2-3/2 software
available at a future release)
- Excellent 0.02 basic accuracy - useful for high
efficiency measurements - Accurate on all waveforms
- Samples continuously, without gaps at 5 MSPS so
there is no missing data during integration or
low-power standby measurements. - Versatile current channel input for low current
measurements. 1A Voltech plug-in shunt available.
20PM6000 Accessories
- Clamp-on Current TransformersCL100
100A1ACL1000 1000A1ACL3000 3000A1A - Precision 0.2CTDual ration 10001A, 1001A
- PS1000 Inrush SwitchPLL switch for inrush
testingSwitch at peak or zero-crossing of
voltage - Ballast CT1MHz CT for HF ballastsDifferential
current transformerSimplifies wiring and
measurements of tube power
21PM6000
New generation power analyzer from Voltech 1 to 6
channels PC based instrument with versatile
display and interface features Ideal for all
power measurements on all electrical and
electronic products PCI bus for 5MSPS data
continuously Voltech know-how for unique
combination of accuracy, bandwidth and common
mode rejection.