Title: The Chillgard L Series Product Line
1The Chillgard L Series Product Line
The refrigerant monitoring industry leader Home
of proven, reliable Photoacoustic Infrared
Technology Brings you a major advancement in PIR
sensing technology
2The Chillgard L Series Product Line
Improved PIR sensing
New advances in micro-machined technology
3The Chillgard L Series
- Features a new optical bench
- Micro-machined optics
- Significant technological advancement
- Used on all Chillgard LS and LE Gas Monitors
- Improved reliability 2-year warranty
- Backwards-compatible with existing units
- New product labeling includes website and new
MSA logo
4The Chillgard L Series System Approach
Flexibility to meet
- Refrigerant monitoring needs
- Remote signaling and control
- Power requirements
- Budget
5Chillgard L Series Product Line
- Chillgard LS Refrigerant Monitor
- Economical low level monitoring of refrigerant
gases - Sensor unit with analog and digital output
- Chillgard LC Control Module
- Controls up to 8 Chillgard LS Sensors
- Multiple outputs and relays
- Chillgard LE Refrigerant Monitor
- Combined features of Chillgard LS and LC Gas
Monitors within one enclosure - Combined multi-point sensing and controlling
6Chillgard LS Refrigerant Monitor Features
- Photoacoustic IR sensor
- Standard gases R123, R134a, R11, R12, R22
- Minimum detection level - 20ppm
- Single-point diffusion or 4-point pumped models
7Chillgard LS Refrigerant Monitor Features
- Compliant with ANSI/ASHRAE 15
- UL approval
- Water- and corrosion-resistant plastic enclosure
- Easy operation, installation and maintenance
- 2-year warranty
8Chillgard LS Refrigerant Monitor Features
- 24 VAC/DC or 110/220 VAC power
- 5 LEDs indicate power, fault and 3 levels of
alarm - 4-20 mA and RS-485 outputs (to Chillgard LC
Controller)
94-20 ma
Pressure transducer (pumped units only)
24 V AC/DC input
485 termination jumper
Sensor Board
RS-485 connector
RS-485 address
Calibration box
Factory use
Strobe
2 bench screws
10Chillgard LS Refrigerant Monitor Optional Gases
R400 and R500 series of refrigerants
- Blends of multiple refrigerants to obtain good
thermodynamic properties in the chiller, with
reduced corrosion and ozone depletion potential. - Includes R404a, R410a, R407c, R507
- Order with custom calibration
- Other refrigerants possible
11Chillgard LS Refrigerant Monitor
- Accessories
- Unit-mounted Strobe
- Calibration box
- Remote light towers
- Calibration kits
- Chillgard LC Controller
12New Photoacoustic Optical Bench
pumped bench
diffusion bench
13Maintenance and Repair
- No moving parts in diffusion-mode Chillgard
LS Monitor
- Optical bench is field-replaceable
- for convenient repair
- for detection of a different refrigerant
14Chillgard LS Refrigerant Monitor Summary
- Low cost refrigerant sensor
- Improved PIR technology
- Easy to install, operate and maintain
- Can be stand-alone or used with Chillgard LC
Controller
15Chillgard LC Controller
16Chillgard LC Control Module Features
- Capable of controlling up to 8 Chillgard LS
Sensors - Easy-to-use digital display with 4-button keypad
- Provides gas reading, alarm status,
calibration and fault diagnostics - Water- and corrosion-resistant enclosure
17Chillgard LC Control Module Features
- 4-20mA and RS-232 output
- 0-10 V point identifier output
- 4 relays - 3 levels of alarm fault
- 85 dB horn, 100 dB horn option
18Chillgard LC Control Board
19(No Transcript)
20Home-run communication wiring
Bus communication wiring
21Powering the Chillgard LS Sensor
- Power locally via 24 VAC or DC
- Power locally via 110/220 VAC optional supply
- Power via Chillgard LC Control Module
22Powering the Chillgard LC Controller
- 24 VAC or DC
- 110/220 VAC optional supply
- Can be used to power one Chillgard LS Monitor
23Powering the Chillgard LC Controller
- Transformer version
- Powers Chillgard LC Monitor and up to 5
Chillgard LS Sensors
24Chillgard L Series Power Options
25Chillgard L Series Power Options
26Chillgard L Series Power Options
27Chillgard L Series Power Options
110/220 VAC AVAILABLE
LC transformer version
Transformer version powers up to 5 diffusion
Chillgard LS Monitors or two 4-point pumped
Chillgard LS Monitors
28Chillgard LC Control Module
- Accessories
- Unit mounted strobe
- Remote light towers
- Calibration kits
29Chillgard LC Control Module Summary
- Low cost controller
- Controls up to 8 Chillgard LS sensors
- Multiple outputs
- Configurable to meet your needs
- Easy to install, operate and maintain
30Chillgard LE Refrigerant Monitor
- Combined features of Chillgard LS and LC
products in one enclosure - Combined multi-point sensing and controlling
31Chillgard LE Refrigerant Monitor Features
- Photoacoustic IR sensor
- Standard gases R123, R134a, R11, R12, R22
- Minimum detection level - 20ppm
- Single-point diffusion, single-point pumped or
4-point pumped models
32Chillgard LE Refrigerant Monitor Features
- Complies with ANSI/ASHRAE 15
- UL approval
- Water- and corrosion-resistant plastic enclosure
- Easy to operate, install and maintain
- 2-year warranty
33Chillgard LE Refrigerant Monitor Features
- 24 VAC/DC or 110/220 VAC power
- Easy-to-use digital display with 4-button keypad
- Provides gas reading, alarm status,
calibration and fault diagnostics - Water- and corrosion-resistant enclosure
34Chillgard LE Refrigerant Monitor Features
- 4-20mA and RS-232 output
- 0-10 V point identifier output
- 4 relays - 3 levels of alarm fault
- 85 dB horn, 100 dB horn option
35Chillgard LE Series Power Options
36Chillgard LE Refrigerant Monitor Optional Gases
- R400 and R500 refrigerant series
- Blends of multiple refrigerants to obtain good
thermodynamic properties in the chiller, with
reduced corrosion and ozone depletion potential. - Includes R404a, R410a, R407c, R507
- Order with custom calibration
- Other refrigerants possible
37Chillgard LE Refrigerant Monitor Summary
- Low cost refrigerant sensor
- Improved PIR technology
- Multiple outputs
- Configurable to meet your needs
- Easy to install, operate and maintain
38Chillgard L Series Summary
Effective meets ASHRAE standards for
refrigerant monitoring Flexible
configurable to meet application needs Advanced
new photoacoustic infrared bench
design Efficient detects low levels of
refrigerant gas with low cost of
ownership
39Refrigerant Monitors the Competition
40Bacharach HGM 300 RDM 800
- HGM 300 Sensor, RDM 800 Controller
- Non-dispersive IR
- 0-10,000 ppm
- Claimed sensitivity 1 ppm
- Most refrigerants except ammonia
- Pumped, 4-16 points
- Auto-zero 40 seconds every 10 minutes
minimum - Power 110/220 V
41Auto Zeroing
Potential for incorrect zeroing Cannot detect
a hazardous gas if improperly zeroed
Non-continuous gas monitoring No protection
during auto-zeroing process
Increased maintenance Must maintain air line
or scrubber
42Selling the Chillgard L Series versus Bacharach
HGM 300/RDM 800
- Bacharach unit
- Base list price in 6K range
- High-end monitor competes versus Chillgard RT
- Auto-zero requires fresh air and takes monitor
off line for a period of time. Potential for
incorrect readings. - HGM 300 requires RDM 800 controller
- Pump used on HGM 300 known for high repair rate
43Bacharach HGMSZ
- Non-dispersive IR
- 0-10,000 ppm
- Claimed sensitivity 1 ppm
- Most refrigerants
- Pumped, 4-16 points
- Auto-zero 40 seconds every 10 minutes
minimum - Power 110/220 VAC
44Selling the Chillgard L Series versus Bacharach
HGMSZ
- Bacharach unit
- Single-point only
- Uses wide band optics gt cross-sensitive to
other gases - Sample draw system which only pulls 50 feet
- Auto-zero requires fresh air and takes monitor
off line for a period of time. Potential for
incorrect readings.
45OI Analytical SAM Refrigerant Monitors
- Non-dispersive IR
- 0 1000 PPM
- Claimed noise level and accuracy /- 1 ppm
- R11, R12, R22, R123, R134A, CO, ammonia
- Pumped, SAM-I 1 to 8 ports, SAM-IV 1 to 11
ports - Power 110/220V
- Auto-zero 45 seconds, every 1hr minimum
46Selling the Chillgard L Series versus OI
Analytical SAM Monitors
- SAM Unit
- Base list price in 7.5 K range
- High-end monitor competes versus Chillgard RT
Monitor - Auto-zero requires fresh air and takes monitor
off line for a period of time. Potential for
incorrect readings. - Product sales and support is minimal
47Vulcain 301 IRFS
- Non-dispersive IR
- Range 0-1,000 ppm
- Diffusion sensor
- 6 standard refrigerants
- Tested sensitivity 30-50 ppm
- 10 V output
48Selling the Chillgard L Series versus Vulcain
IRFS
- Vulcain Unit
- Single-point only
- Product drift especially with temp change
- Diffusion only
- Long response time to fill enclosure 7 to 10
minutes - 24 V power only
- Tested sensitivity 30-50 ppm
- No UL approval (ETL approval)
49Genesis Sherlock Infrared Refrigerant Sensor
- Non-dispersive IR
- Range 0-1,000 ppm
- Diffusion sensor
- 11 standard refrigerants
- 0-5 V or 4-20 mA output
50Selling the Chillgard L Series versus Genesis
Sherlock sensors
- Genesis Unit
- Single-point only
- Product drift inherent to NDIR
- Recommended calibration every 6 months
- Diffusion only
- Long response time to fill enclosure (7 to 10
minutes) - 10-24 VDC power only
- No known approvals
51Chillgard L Series Product Line