Liquid Penetrant Testing - PowerPoint PPT Presentation

About This Presentation
Title:

Liquid Penetrant Testing

Description:

Global NDE Guru is an eLearning project of NDT Consultancy Services Inc., a quickly developing, innovation driven organization concentrated on making way breaking on the web ndt preparing, affirmation, training, assessment and NDT Level III counseling Services over the field of non-dangerous testing. – PowerPoint PPT presentation

Number of Views:722

less

Transcript and Presenter's Notes

Title: Liquid Penetrant Testing


1
Liquid penetrant testing
  • This is a method which can be employed for the
    detection of open-to-surface discontinuities in
    any industrial product which is made from a
    non-porous material. This method is widely used
    for testing of non-magnetic materials. In this
    method a liquid penetrant is applied to the
    surface of the product for a certain
    predetermined time, after which the excess
    penetrant is removed from the surface. The
    surface is then dried and a developer is applied
    to it. The penetrant which remains in the
    discontinuity is absorbed by the developer to
    indicate the presence as well as the location,
    size and nature of the discontinuity.
  • Penetrants used are either visible dye penetrant
    or fluorescent dye penetrant. The inspection for
    the presence of visible dye indications is made
    under white light while inspection of presence of
    indications by fluorescent dye penetrant is made
    under ultraviolet (or black) light under darkened
    conditions. The liquid penetrant processes are
    further sub-divided according to the method of
    washing of the specimen. The penetrants can be.
  • (i) water-washable
    (ii) postemulsifiable

2
i.e. an emulsifier is added to the excess
penetrant on surface of the specimen to make it
water-washable, and (iii) solvent removable, i.e.
the excess penetrant is needed to be dissolved in
a solvent to remove it from the test specimen
surface. In order of decreasing sensitivity and
decreasing cost, the liquid penetrant processes
canbelistedas
  • Post emulsifiable fluorescent dye penetrant.
  • Solvent removable fluorescent dye penetrant.
  • Water washable fluorescent dye penetrant.
  • Post emulsifiable visible dye penetrant.
  • Solvent removable visible dye penetrant.
  • Water washable visible dye penetrant.

3
(No Transcript)
4
Some of the limitations of liquid penetrant
testing are as follows
  • Test surface must be free of all contaminants
    (dirt, oil, grease, paint, rust, etc.
  • Detects surface discontinuities only.
  • Cannot be used on porous specimens and is
    difficult to use on very rough surfaces.
  • Removal of all penetrant materials, following the
    test, is often required.
  • There is no easy method to produce permanent
    record. 