Title: Mmwave diagnostics on the 170 GHz test facility
1Mm-wave diagnostics on the 170 GHz test facility
Checking polarization using Rotating probe. Can
be done directly in the beam or using a foil
Beam profiling using IR camera
Water load
Vacuum vessel for steerable mirror
Window
MOU
Mmw-beams
Transmission line
Hinge for movable vacuum vessel
Looking through using IR camera (detection of
hotspots)
2High power 110 GHz polarization measurementsby
means of a rotating probe at TEXTOR
Dogleg
110
1140
MOU
Switchmirror dump
MTP and
Polarizer
845
4555
MP2
0.4 MW, duty cycle 1100 10 ms/shot, synchronized
to gyrotron trigger.
3Rotating probe shielding and location
4Curve fitting of the rotation scan of the probe
to obtain ellipticity and ellipse
The detector signal of the probe is sampled with
5 ms averaging (during the shot) by an ADC and
converted with a calibration table to power.
Actual high power measurement!
Horizontal polarization measurement, probe starts
and finishes with vertical polarization
5Ellipticity result of polarization measurements
Theoretical
Measured at high power
6Angle of ellipse result of polarization
measurements
Theoretical
Measured at high power
7IR Camera window material
- IR camera specs
- AVIO MK2000 MkII (gas cooled)
- Detection wavelength 3..5.4 ?m
- FOV horizontal 15
- vertical 10
- IR camera (250x200x100 mm3)could be used to see
the beam profile using a foil or looking at a
window. - Can be used to determine power
- Fused silica window, not suitable for use as
transparent medium with this IR camera
Pulse length 10 ms 1.5 MW 1100 duty cycle