Title: The Ultimate Pressure Control
1The Ultimate Pressure Control
2Digihelic
- Who Has Not Sold a Digihelic????????
- IF YOU HAVE NOT YET, YOU ARE MISSING EASY SALES
OPPORTUNITIES
3Digihelic Capabilities
- Selectable Engineering Units
- Pressure
4Digihelic Capabilities
- Selectable Engineering Units
- Air Velocity
- FPM, M/S
- Air Flow
- SCFM, M3/HR
5Digihelic Capabilities
- Display of Full Scale Instead of Eng. Units
- Records Peak Valley Readings
- 4 Levels of Security
- Truly Universal Power Supply
- 120 VAC 240 VAC 24 VDC
- 4-20 mA Standard on ALL Models
- K-Factor Selection for Various Flow Sensors
- Digital Dampening of Display Output
6Digihelic Capabilities
- Full Scale Accuracy of 0.5 on Ranges
- 0-0.25 .25-0-.25" w.c. (60 Pa 60 Pa)
- 0-1 1-0-1" w.c. (250 Pa 250 Pa)
- 2.5-0-2.5" w.c. (620 Pa)
- 0-5 5-0-5" w.c. (1.25 kPa 1.25 kPa)
- 0-10 10" w.c. (2.5 kPa 2.5 kPa)
- 0-25" w.c. (6.23 kPa)
- 0-50" w.c. (12.45 kPa)
- 0-100" w.c. (25 kPa)
7Digihelic Capabilities
- Quick Field Calibration Via Menu Buttons
- 4 20 mA Process Rescaling
- Hot Key for Quick Access to Set Point/Alarm
Viewing or Adjustment - Modbus Communications Standard
- 2 SPDT 8 Amp Relays
8Digihelic Capabilities
- 3 Modes of Operation
- Single Set Point with Adjustable Dead Band
- Dual Set Points with Adjustable Dead Bands
- Single Set Point with Separate Alarm Output
LED Indication of Set Point or Alarm
Activation
9Digihelic Capabilities
- Mode with Single Set Point Separate Alarm
- Selectable
- High Alarm, Low Alarm, or High/Low
- Auto or Manual Reset (Via Button on Face)
- Alarm Inhibit
- Alarm Time Delay
10Digihelic Competition? ? ?
- Meriam
- Modus
- Precision Sensors
- (Division of United Electric)
11Digihelic VS. Meriam 2100
- Meriam 2100
- Lowest Range of 20" w.c.! (5 kPa)
- 1 Model for Pressure 2nd Model for Flow
- 1 Model for 120 VAC
- Available Only with Switches
- 2nd Model for 24 VDC
- Available Only with 4-20 mA Output
- Priced _at_ 795
12Digihelic VS. Modus DA
- Modus DA
- Inaccurate with 1 full span 1 Digit
- No engineering units conversion
- Transmitter Standard. But Switches Optional, and
Another Option for a Square Root Output - 3 Separate Models for 120/240 VAC, 24 VDC
- Price with Alarms 420
- Price with Square Root Output 475
13Digihelic VS. U.E. Echoline
- U.E. Echoline
- 1 Full Scale Accuracy
- Optional Engineering Units Conversion
- No Square Root Output for Air Flow
- Optional 4-20 mA Output
- 12-24 VDC Power Only
- OEM Pricing of 295 Net Regardless of Qty.
14Digihelic VS. Modus Titan
- Modus Titan
- Lowest Range of 2" w.c.
- 2 Metric Ranges in Pa Optional
- Optional LED Display of Set Point Activation
- Relay Outputs Optional
- Process Signal Output Optional
- Price 330 2 Amp Relays Process Output
15Digihelic Endless Potential
- Customer Using a D.P. Gage Separate D.P.
Transmitter? - ORDER A DIGIHELIC
16Digihelic Endless Potential
- Need a Differential Pressure Switch Set Point
Indication on a Control Panel? - ORDER A DIGIHELIC
17Digihelic Endless Potential
- Need a Photohelic and Separate High Alarm?
- ORDER A DIGIHELIC
18Digihelic Endless Potential
- Need a D.P. Gage/Transmitter with a Scale in mm
w.c., mm Hg, kPa, Ft. w.c., hPa, cm w.c. or mBar? - ORDER A DIGIHELIC
19Digihelic Endless Potential
- Need a D.P. Gage with Special SCFM or M3/Hr Air
Flow Scale? - ORDER A DIGIHELIC
20Digihelic Endless Potential
- Need a Differential Pressure Transmitter with
Modbus Communications Output? - ORDER A DIGIHELIC
21Digihelic Endless Potential
- Need a Differential Pressure Transmitter with
Data Logging Capabilities? - ORDER A DIGIHELIC
22Digihelic Endless Potential
- Do You Have Customers Who
- Observe Pressure in Clean Rooms?
- Monitor Gas Cabinet Exhaust Systems?
- Control Dust Collection Cleaning Systems?
- Control Dampers on Industrial Ovens?
- Control Air Handlers Fan Output?
- Monitor Proper Fume Hood Flow?
- Ensure Proper Glove Box Pressurization?
23Still Not Convinced?
- Ask Our Customers
- Temtrol
- Manufacturer of Air Handling Units
- Germfree Laboratories
- Leaders in Bio-Safety Cabinets
- The Baker Company
- Bio Cabinets and Fume Hoods
- Sez Inc.
- Wafer Processing Environmental Chambers
24U.S. Fortune 500 Customers
- Tyson Foods Food Processing
- Eastman Kodak Photographic Paper
- Bayer Corporation Drug Manufacturer
- Honeywell, Trane Johnson Controls Building
Automation Systems - General Electric Global Research Center
25Unique Application
- PSEG (Public Service Electric Gas)
- Coal Burning Power Plant in New Jersey
- Trying to Control NOx Emissions
- Selective Catalytic Reduction (SCR) Process
Reduces NOx 50-60 - SCR Injects Ammonia into the Exhaust
- Utilize an Averaging Pitot Array and 0-5" w.c.
Digihelic to Monitor the Air Flow in SCFM - Monitor the Flow System Wirelessly and Can Adjust
as Needed
26Digihelic Links
- Communications Program for the Digihelic
27Digihelic Links
- Communications Program
- Enables Customer to Set or Change Any Parameter
in the Digihelic from a Computer - An Entire Plant of Digihelics Can be
Monitored/Controlled from A Single Location - User Can Review an Event Log, Graph Data,
Calibrate Zero Span
28The Ultimate Pressure Control
- In Summary the Digihelic
- Has the Capacity to Be Selected for Almost any
Pressure or Air Flow Application - Provides Core Dwyer Customers the Ability to Have
the Highest Possible Control of Their Application
in One Product