Powerware 9170 3 18 kVA - PowerPoint PPT Presentation

1 / 26
About This Presentation
Title:

Powerware 9170 3 18 kVA

Description:

Adheres to IEC guidelines for Class 1 double conversion online UPS ... Housed in standard UPS cabinet or special 12 slot battery cabinet (ASY-0653) Top 3 slots ... – PowerPoint PPT presentation

Number of Views:258
Avg rating:3.0/5.0
Slides: 27
Provided by: christoph268
Category:
Tags: kva | powerware | ups

less

Transcript and Presenter's Notes

Title: Powerware 9170 3 18 kVA


1
Powerware 91703 - 18 kVA
The modular, scalable, redundant UPS for midrange
applications
2
The Powerware 9170Its about availability
  • Reliability
  • Efficiency
  • Performance

3
Powerware 9170 Applications
  • The 9170 is designed for the 24/365
    availability needs of 3-18 kVA e-business
    applications featuring
  • Servers
  • Networking devices (hubs, routers and switches)
  • Telecommunications/PBX
  • Long Runtime Applications (with new Charger
    Module)
  • Process control
  • Branch offices

4
Powerware 9170 Enhancements
  • XCP Protocol Compatibility
  • Increase Watt Rating - Split Phase Modules
  • Advance Battery Management (ABM)
  • Improved Front Panel Operations
  • Firmware Field Upgrade Capability
  • Active MOV Monitoring

5
Powerware 9170Overview
  • Modular, global design
  • Scalable
  • N X redundancy
  • Traditional 9 Series Power Protection
  • Advanced Battery Management (ABM)
  • Optional Charger for Long Runtime Applications
  • Compact footprint/lightweight power
  • and battery modules
  • Enhanced, easy to use interface panel
  • Flexible communication capability

6
Powerware 9170 System Configurations
Four freestanding UPS enclosures
3-slot 3 kVA 6-slot 3-9 kVA 9-s
lot 3-18 kVA
12 slot 3-18 kVA
The Powerware 9170s modular design lets users
configure any level of power redundancy or
battery run-time with optional charger they need.
7
Powerware 9170 System Configurations
Three freestanding Battery Enclosures
6 Slot 9 Slot 12 slot 12 Slot w/charger
Two rackmount kit options 3-slot 3 kVA
6-slot 3-9 kVA
8
Powerware 9170 System Configurations
Model Power Input/Output Input/Output Dimensions
Number Rating Voltage1 Connection(s) ( H x W x
D) 2 Weight . PW9170 3 slot 3kVA
208-240VAC Configurable 17.8 x 17 x 25.4 in.
66 lb . PW9170 6 slot 3 to 9kVA 208-240VAC
Configurable 31.5 x 17 x 25.4 in. 103 lb
PW9170 9 slot 3 to 18kVA 208-240VAC
Configurable 47 x 24 x 28.4 in. 158 lb
PW9170 12 slot 3 to 18kVA 208-240VAC
Configurable 60.7 x 24 x 28.4 in 196 lb
6 slot battery cab 31.5 x 17 x 25.4 in
93 lb 9 slot battery cab 47 x 24 x 28.4 in 14
8 lb 12 slot battery cab 60.7 x 24 x 28.4 in 1
86 lb Battery Module 4.2 x 7 x 14.8 in 30 lb
Split Phase Power Module 100 - 120 200
- 240VAC 4.2 x 14.1 x 15.3 in 17 lb
Universal Power Module 200 - 240VAC
4.2 x 14.1 x 15.3 in 17 lb Optional Charger Modul
e 4.2 x 14.1 x 15.3 in 17 lb
1. Nominal input voltage range is 208 - 240VAC
with maximum input voltage range of 176 to
276VAC. Split Phase Power Module offers both
high and low output voltages, while the Universal
Power Module offers only high output voltages.
9
Powerware 9170 Benefits / Features
  • Cost of Ownership
  • Capacity Modular in 3kVA blocks
  • NX option
  • Charger option

10
Powerware 9170 Standard Features
  • Global Product
  • WW Frequency (47-63Hz)
  • Selectable WW voltages
  • High efficiency mode
  • Enhanced, Fault Bypass mode
  • Standard hot-swappable internal batteries
  • Continuous on-line, no-break transfer
  • Sinewave Output

11
Powerware 9170 Standard Features
  • Generator compatible
  • Advanced Battery Management (ABM)
  • Wide input voltage
  • 176 - 276 volts
  • Supports
  • non-linear loads
  • 31 crest factor
  • .9 lead to .5 lagging
  • Power factor corrected

12
Powerware 9170 Standard Features
  • LCD display
  • Complete connectivity offering
  • Com slot(s)
  • RS232
  • Contact closure
  • Remote EPO capable
  • etc.
  • Enhanced ,Easy diagnostics
  • Power management software - XCP Compatible

13
Powerware 9170 Maximum Availability
  • True double conversion online design
  • Adheres to IEC guidelines for Class 1 double
    conversion online UPS
  • Total independence and complete isolation between
    input and output for voltage and frequency
  • Wide input voltage range (176 to 276 VAC)
  • Frequency correction
  • Harmonics isolation

Double conversion online is universally
recognized as the highest performance topology
14
Powerware 9170Maximum Availability / Reliability
  • Features
  • Patented Universal Slots
  • Any module - any slot
  • Hot Swappable Modules
  • All modules with no load interruption
  • Patented Bypass
  • 6kVA rated

15
Powerware 9170 Maximum Reliability
  • NX Power and LOGIC Redundancy
  • Patented technology enables true NX power
    redundancy
  • The Powerware 9170 features logic redundancy as
    well, eliminating any vulnerability to system
    availability. The logic is contained in each
    3kVA Power Module (not in separate redundant
    logic cards like Symmetra, Nfinity, etc.),
    allowing true NX Power and Logic Redundancy
  • No system-level single-point-of-failure in
    Powerware 9170 systems
  • Virtually eliminates downtime and enhances
    serviceability no need to transfer load to
    bypass during service

16
Powerware 9170 Standard Internal Options
  • Receptacle panels
  • All cabinets
  • Input cord options
  • 3 6 kVA only
  • Locking casters option
  • 3 6 Slot only

17
Powerware 9170 Optional Charger Module
  • Optional 20AMP Charger
  • 20 amps of charging capability which can be
    paralleled for long runtime opportunities
  • Same Form Factor as 3kVA Power Modules
  • Fits any standard slot
  • Housed in standard UPS cabinet or special 12 slot
    battery cabinet (ASY-0653) Top 3 slots
  • Example
  • 18kVA system for 1 hour of runtime
  • One charger will yield 5.4 hours of recharge
    time
  • Two chargers will yield 3.1 hours of recharge
    time.

18
Powerware 9170 Internal Options
  • Galvanic isolation
  • (factory installation required)
  • 3 Slot
  • Housed in bottom of cabinet
  • Removes bottom slot
  • 6 Slot
  • Mounted vertical rear
  • Reduces receptacles to maximum 4 bays
  • 9 Slot - not available
  • 12 Slot
  • Mounted vertical rear
  • Reduces receptacles to maximum 8 bays

19
Powerware 9170 External Option
  • Rackmount kits
  • Extended runtime
  • 6, 9, 12 slot cabinets
  • Wall mounted MBC
  • Make Before Break (MBB)
  • Break Before Make (BBM)
  • Floor anchoring kits

20
Powerware 9170 Maximum Performance
  • Enhanced, easy-to-use front control panel
  • Large 4 X 20 character back-lit LCD panel
  • Programmable for Power Saver Mode, alarm
    notification
  • and communications
  • Illuminated indicators for UPS status
  • Multilingual LCD (English, French, German and
    Spanish)

21
Powerware 9170 Maximum Performance
  • Flexible communication capabilities
  • SNMP communication
  • RS-232 DB-9
  • Web browser or
  • modem access
  • Software included
  • On Line, On Generator,
  • On Bypass, EPO notification
  • Two communications slots

22
Battery Runtime Chart
(Full load/Half load)
Runtimes above solid line require new optional
charger or additional power modules.
23
Battery Runtime Chart
(Full load/Half load)
Runtimes above solid line require optional
charger or additional power modules.
24
Power ware 9170 Pre-configured System Numbers
  • Pre-configured 9170 UPS System Numbers
  • Displayed on Powerware web site on 9170 page
  • Complete 9170 UPS Systems, including enclosure,
    Power and Battery Modules.
  • Available to ship immediately
  • Customer can order a complete 9170 UPS System
    with one part number or configure their own
    unique 9170 UPS system the best of both worlds.

25
Powerware 9170 Pre-configured System Numbers
26
Powerware 9170
  • Thank You
Write a Comment
User Comments (0)
About PowerShow.com