Otto Bock Shape System Online Course - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

Otto Bock Shape System Online Course

Description:

Components are not interchangeable between Isotrak and Patriot ... You will need to install a driver for the Patriot SEU to work properly. ... – PowerPoint PPT presentation

Number of Views:225
Avg rating:3.0/5.0
Slides: 21
Provided by: bell77
Category:

less

Transcript and Presenter's Notes

Title: Otto Bock Shape System Online Course


1
Otto Bock Shape System Online Course
  • John Phillips, ATS
  • Seating, Positioning Mobility
  • Clinical Specialist

2
OBSS Version 6.5
  • Agenda
  • Introductions 15 minutes
  • Review Equipment Changes 15 minutes
  • Review Software Changes 1 hour
  • Review Interactive Order Form 15 minutes
  • Wrap-up/Software Installation 15 minutes

3
OBSS Version 6.5
Digitizing Equipment
  • SEU
  • Sensor (stylus)
  • USB Cable
  • Source

4
OBSS Version 6.5
SEU -Systems Electronic Unit
  • Patriot can only be operated by V6.5 software
  • Isotrak can be operated by either 5.0 or 6.5.
    software. Plastic instead of metal box

5
OBSS Version 6.5
SEU -Systems Electronic Unit
  • LED indicator starts out red and changes to green
    if SEU is working properly
  • Components are not interchangeable between
    Isotrak and Patriot
  • Only USB cable can be used with Patriot

6
OBSS Version 6.5
Software Changes
  • Data Station
  • OBSS Designer
  • Order Form
  • Sending files

7
OBSS Version 6.5
Software Changes-Data Station
  • CAD Center now labeled Data Station
  • File ? Export as OBD File OBD files only serve
    as information for exchange or checking. They
    cannot be sent by email as a job order to Otto
    Bock. This prevents the accidental ordering of
    data for which only a review was required. OBD
    files which have been imported from another Otto
    Bock Data Station installation can only be
    re-exported as OBD files. They cannot be emailed
    as a job order file (BD4). This means that the
    responsibility of ordering a job remains with the
    original creator of that job.

8
OBSS Version 6.5
Software Changes-Data Station
  • Edit ? Options ? View Group Patients -When this
    option is checked, an additional level is added
    into the patient tree which allows patients to be
    subdivided into groups. It is not possible to
    uncheck this option once groups have been
    created.
  • Edit ? Options ? View Dont show jobs before
    this date Only shows jobs created after the
    date you select

9
OBSS Version 6.5
Software Changes-OBSS "options" menu
  • Edit ? Options ? Digitizer Adjust this setting
    to match the model of the digitizer you are
    currently using.

10
OBSS Version 6.5
Software Changes-OBSS "options" menu
  • Edit ? Options ? Cutting Box Values on the
    Cutting Box Options form are used to calculate
    the initial size of the Cutting Box at the end of
    digitization. By applying the appropriate padding
    to the digitized surface. The Left Padding and
    Right Padding are displayed as yellow lines at
    the leftmost and rightmost extremes of the
    digitized curves. The Back Padding and Base
    Padding are calculated to guarantee the minimum
    thickness of the Back and Seat for a given Back
    Angle.

11
OBSS Version 6.5
Software Changes-OBSS "options" menu

New digitizing method
Previous digitizing method
Old method
New method
12
OBSS Version 6.5
Software Changes-OBSS "View" Menu
  • View ? Foam Block Trims the cushion to the
    cutting box and displays it as a solid 3D shaded
    model
  • View ? Curve Numbering Displays the number of
    each curve in the cushion view
  • View ? End Points Indicates the end points of
    each curve in the cushion view with a circled
    cross
  • View ? Markers Displays any markers and lines
    which have been digitized.

13
OBSS Version 6.5
Software Changes-OBSS "Edit" Menu
  • Edit Cushion ? Hide Curves Hides all curves
    which are not selected.
  • Edit Cushion ? Move Curve Moves the selected
    curve(s) in the x, y or z directions. A dialog
    box is displayed to control the amount of
    movement in each direction.
  • Edit Cushion ? Mirror Left Side of Cushion
    Copies all points on each curve which lie to the
    left of the center of the cushion to an
    equivalent position on the right-hand side of the
    cushion.

14
OBSS Version 6.5
Software Changes-OBSS "Edit" Menu
  • Edit Cushion ? Mirror Right Side of Cushion
    Copies all points on each curve which lie to the
    right of the center of the cushion to an
    equivalent position on the left-hand side of the
    cushion
  • Edit Cushion ? Tilt Cushion Tilts the cushion
    data in space. A dialog box is displayed to
    control the amount that the cushion data tilts.
  • Edit Cushion ? Scale Cushion Increase or reduces
    the overall size of the cushion. A dialog box is
    displayed to control the amount that the cushion
    is increased or reduced in size. The scaling is
    done in x, y or z directions separately.

15
OBSS Version 6.5
Software Changes-OBSS "Where" Marker Icons
  • Marker ? allows input of a single where marker
    into the digitized image
  • Labeled Marker ? Allows the user input a where
    marker with a text label attached
  • Labeled Line ? Allows the user input a series of
    where marks that will connect to form a solid
    line with a text label attached

16
OBSS Version 6.5
Order Form Review

17
OBSS Version 6.5
Sending Files to Fabrication Services
Emailing patient files It is now possible to
email patient files to the Otto Bock Technical
Center directly from the OBSS software. With the
patient name highlighted in the CAD Center,
either right mouse click or use the File
pull-down menu then select email job and left
mouse click. A window will appear that will ask
you to enter your name as a contact name for this
job. After you enter that information, your mail
management program will be automatically opened
and the patient file will be inserted into a new
mail message. Your account number, date the file
was sent, patient name and contact name will
appear in the subject line of the email message.

18
Points To Remember!
  • New digitizing procedure
  • Order form must be completed before digitized
    file can be emailed to the fabrication center
  • Seat depth determined by furthest point on first
    digitized curve
  • Back height determined by highest point on top
    digitized curve
  • Practice before molding first client

19
OBSS Version 6.5
Software Installation
  • Note In order to install Version 6.5 you must
    remove previous versions! You will need to
    install a driver for the Patriot SEU to work
    properly. This only needs to be performed once.
    (will not work Windows 98 or ME operating system)

20
OBSS Version 6.5
Software Installation
  • In order to install the software you will need to
    visit the website listed below and complete a
    brief evaluation before downloading is possible.
    If you wish to receive a cd of the software
    instead of, or in addition to downloading the
    software, please fill out the necessary
    information on the website.
  • http//www.obproservices.com/education/obss/obss.a
    spx
  • Session Code___________
Write a Comment
User Comments (0)
About PowerShow.com