Title: Simple Performance Tests for HotMix Asphalt Concrete
1Simple Performance TestsforHot-Mix Asphalt
Concrete
- Ramon Bonaquist, P.E.
- Chief Operating Officer
- Advanced Asphalt Technologies, LLC
Simple Performance Test
2What Is It?
- Test That Indicates How Mix Will Perform
- Rutting
- Cracking
1. Identify Inferior Mixes 2. QC/QA
Operations 3. Structural Design
3Lots of Possibilities
- Gyratory Compactor
- Rut Testers
- Asphalt Pavement Analyzer
- Hamburg
- Fundamental Tests
- Uniaxial/Triaxial
- Shear
- Indirect Tensile
- Many Show Promising Correlation With Pavement
Performance Using Limited Data Sets
4NCHRP/FHWA Research
- To Recommend a Fundamental Based but Simple
Performance Test(s) to Support of the Superpave
Volumetric Mix Design Procedure - Started 1997 FHWA Leadership
- Moved to NCHRP in Late 1998
- Continue Through Early 2003
5Simple Performance Test Requirements
- Absolute Requirements of Test
- Compliment Superpave Volumetric Design
- Use Gyratory Compacted Specimens
- High Correlation to Rutting/Fracture
- Identify Inferior Mixes
- Preferred Requirements of Test
- Tied to Structural Design
- Adaptable to QC/QA
6Two Major Projects
- NCHRP Project 9-19
- Recommend Test(s)
- Develop Protocol(s)
- Develop Criteria
- Validate Criteria
- NCHRP Project 9-29
- Equipment Specs
- Procure First Articles
- Evaluate First Articles
- Revise Specs
7Recommend Tests
- Identify Existing Test Methods
- Correlation Study
- Relate Test Parameters to Observed Performance
- Well Documented Experimental Sections
8Sites for Correlation Study
MnRoad
WesTrack
FHWA-ALF
9(No Transcript)
10Recommend Tests
- Identify Existing Test Methods
- Correlation Study
- Relate Test Parameters to Observed Performance
- Well Documented Experimental Sections
- Select Candidate Tests
11Candidate Tests
- Dynamic Modulus
- Rutting
- Cracking
- Creep Test
- Rutting
- Repeated Load Test
- Rutting
12Dynamic Modulus Test
- Rutting
- Min E at High Temp
- Fatigue Cracking
- Max E at Intermediate Temp
13Creep Flow Time Test
- Rutting
- Min FT at High Temp
14Repeated Load Permanent Deformation Test
- Rutting
- Min FN at High Temp
15Advantages
- Dynamic Modulus
- Used For Structural Design in 2002 Design Guide
- Addresses Rutting and Cracking
- Optimization
- Creep
- Simple Test Equipment
- Minimal Training
- Repeated Load
- Potentially Best Simulation of Actual Loading
16Disadvantage
- Specimen Size
- 100 mm Diameter by 150 mm High
- Smooth Parallel Ends (Sawed)
- Sawed and Cored From Over-Height Gyratory
Specimens - Some SGC Can Not Produce Tall Specimens
- Needed to Ensure Fundamental Properties
17Project 9-19 Criteria Development
- Use Models Proposed in Project 1-37A for the 2002
AASHTO Design Guide - Account for
- Climate
- Traffic Level
- Structure
- Test at Effective Pavement Temperature
- Minimum or Maximum Values
- Traffic Level
- Pavement Structure
- Completed in Fall 2002
18Project 9-19 Validation
- Criteria Will Be Validated
- Not the tests
- In-Service Pavement Data
- 50 LTPP and Other Test Sections
- Completed by the End of 2002
Fatigue Cracking
Rutting
19Equipment Specifications
- Automated Specimen Fabrication Equipment
- Creep / Flow Time Test
- Repeated Load / Flow Number Test
- Dynamic Modulus Test
20Specification Development
Draft Equipment Specs Cost Estimate
21First Article Simple Performance Test System
- EnduraTec
- Instron
- Interlaken
- Shedworks
22Project 9-29 First Article Simple Performance
Test Systems
- Tests
- Flow Time
- Flow Number
- Dynamic Modulus
- Temperature Range
- 20 to 60 C
- Confining Pressure Range
- 0 to 210 kPa
23Project 9-29 First Article Simple Performance
Test Systems
INTERLAKEN
SHEDWORKS
24Project 9-29 First Article Simple Performance
Test Systems
25Shedworks
26Shedworks
27Shedworks
28Shedworks
29Interlaken
30Interlaken
31Project 9-29 First Article Specimen Fabrication
System
32Project 9-29 First Article Specimen Fabrication
Equipment
BLADES
CHUCK
CORE BARREL
33Summary- Simple Performance Test Work Completed
- Three Candidate Tests
- Dynamic Modulus
- Flow Number
- Flow Time
- Detailed Draft Protocols
- Detailed Equipment Specifications
- First Article Devices
- Simple Performance Test System (25 k to 45 k)
- Automated Specimen Fabrication System (12 k)
34Summary - Simple Performance Test Work in Progress
- Criteria Development
- November, 2002
- Criteria Validation
- End of 2002
- First Article Evaluation
- Early 2003
35Questions ?
Simple Performance Test