Test Facility Capabilities - PowerPoint PPT Presentation

1 / 8
About This Presentation
Title:

Test Facility Capabilities

Description:

distributes PUS (Packet Utilisation Standard)TM & TC packets around the EGSE subsystems ... implements PUS handling for the test equipment controllers ... – PowerPoint PPT presentation

Number of Views:32
Avg rating:3.0/5.0
Slides: 9
Provided by: pacsSterK
Category:

less

Transcript and Presenter's Notes

Title: Test Facility Capabilities


1
  • Test Facility Capabilities
  • EGSE

2
EGSE overview
3
Router Test Equipment Gateway
  • Router
  • distributes PUS (Packet Utilisation Standard)TM
    TC packets around the EGSE subsystems
  • Test equipment gateway
  • implements PUS handling for the test equipment
    controllers
  • distributes TC packets to the corresponding test
    equipment controller
  • collects all TM packets from the test equipment
    controllers

4
CDMS Simulator
  • implements MIL-STD-1553b communication bus to
    connect DPU and EGSE
  • transfers TM packets from DPU to EGSE
  • transfers TC packets from EGSE to DPU
  • synchronizes DPU time with its own time
  • allows selection of several user defined bus
    lists
  • no mission time line implemented TCs for DPU are
    transferred immediately to DPU after they are
    received from EGSE

5
XY Stage Controller
  • allows positioning of external sources (hole
    mask) via TC
  • reports all moves via TM packets
  • for FM ILT also simple pointing rasters will be
    implemented
  • for FM ILT XY stage scans to support bolometer
    testing will be implemented

6
Test Optic Controller
  • both flip mirrors can be commanded via TC
  • to switch between internal and external
    calibration sources
  • to switch between internal integrating sphere and
    internal black bodies
  • chopper wheel can be commanded via TC to select
    one of the two internal black bodies
  • chopper wheel can be commanded via TC to rotate
    with a selectable frequency to regularly switch
    between the internal black bodies
  • periodic TM packets to report status
  • event TM packets whenever chopper wheel passes
    fixed hall sensors

7
Environment monitor Stimuli control
  • regular HK TM reports from
  • several temperatures inside the cryostat
  • pressure of the cryostat and the gas cell
  • liquid level measurements for N2 and He
  • status, set point, actual temperature and heating
    power for both internal black bodies
  • set point for internal black bodies can be set
    via TC

8
HCSS Interface
  • TM packets together with decompressed dataframes
    will be stored in the HCSS database
  • Test procedures will call for predefined CUS
    observations
  • CUS generated TC sequences will be executed by
    the TestControl/TOPE system
  • Data processing users will be able to fetch
    data associated with a test execution or a CUS
    observation via a browser interface
  • OOL and TC history will be fetched from SCOS and
    ingested into the database
Write a Comment
User Comments (0)
About PowerShow.com