Title: Lecture 12 Pan Joist and Pattern Loads
1Lecture 12 - Pan Joist and Pattern Loads
- September 27, 2002
- CVEN 444
2Lecture Goals
- Pan Joist
- Load Factors
- Pattern Loading
- One way Slabs
3Pan Joist Floor Systems
View of Pan Joist Slab from Below
Walter P. Moore Assoc.
4Pan Joist Floor Systems
Walter P. Moore Assoc.
View of Double Skip Joist Slab from Below
5Pan Joist Floor Systems
Placing Reinforcement for a Pan Joist Slab
Walter P. Moore Assoc.
6Pan Joist Floor Systems
General framing layout of the pan joist system.
7Pan Joist Floor Systems
Pouring a Pan Joist Slab
Walter P. Moore Assoc.
8Pan Joist Floor Systems
- Definition The type of slab is also called a
ribbed slab. It consists of a floor slab,
usually 2-4 in. thick, supported by reinforced
concrete ribs. The ribs are usually tapered and
uniformly spaced at distances that do not exceed
30 in. The ribs are supported on girders that
rest on columns. In some ribbed slabs, the
space between ribs may be filled with permanent
fillers to provide a horizontal slab soffit.
9One-Way Joist Construction
Definition Pan joist floor systems are series
of closely spaced cast-in-place T-beams or joists
used for long-span floors with relatively light
loads. Typically removable metal forms (fillers
or pans) are used to form joists.
MacGregor, Fig. 10-28
10One-Way Joist Construction
Details of ribbed floor with removable steel pans.
Ribbed-floor cross sections.
11One-Way Joist Construction
The design of a ribbed floor with steel pan forms
and average weight of the floor.
12One-Way Joist Construction
The design of a ribbed floor with steel pan forms
and average weight of the floor.
13One-Way Joist Construction
Joist Details
14Pan Joist Floor Systems
- ACI Requirements for Joist Construction
- (Sec. 8.11, ACI 318-02)
- Slabs and ribs must be cast monolithically.
- Ribs must be spaced consistently
- Ribs may not be less than 4 inches in width
15Pan Joist Floor Systems
- ACI Requirements for Joist Construction (cont.)
- (Sec. 8.11.2, ACI 318-02)
- Depth of ribs may not be more than 3.5 times the
minimum rib width - Clear spacing between ribs shall not exceed 30
inches. - Ribbed slabs not meeting these requirements
are designed as slabs and beams.
16Pan Joist Floor Systems
- Slab Thickness
- (ACI Sec. 8.11.6.1)
- t 2 in. for joints formed with 20 in. wide
pans - t 2.5 in. for joints formed with 30 in. wide
pans (1/12 distance)
17Pan Joist Floor Systems
- Slab Thickness (cont.)
- Building codes give minimum fire resistance
rating - 1-hour fire rating ¾ in. cover, 3-3.5 slab
thickness - 2-hour fire rating 1 in. cover, 4.5 slab
thickness
18Pan Joist Floor Systems
- Standard Removable Form Dimensions
- Note the shapes
19Pan Joist Floor Systems
- Standard Removable Form Dimensions
- Standard Widths 20 in. 30 in. (measured at
bottom of ribs) - Standard Depths 6, 8, 10, 12, 14, 16 or 20 in.
20Pan Joist Floor Systems
- Standard Removable Form Dimensions (cont.)
- End Forms one end is closed (built-in) to form
the supporting beam - Tapered End Forms provide additional shear
capacity at ends of joists by tapering ends to
increase rib width.
21Pan Joist Slabs
Standard Pan Joist Form Dimensions Ref. CECO
Concrete Construction Catalog
22Pan Joist Slabs
Standard Pan Joist Form Dimensions Ref. CECO
Concrete Construction Catalog
23Pan Joist Floor Systems
- Laying Out Pan Joist Floors
- Rib/slab thickness
- Governed by strength, fire rating, available
space - Overall depth and rib thickness
- Governed by deflections and shear
24Pan Joist Floor Systems
- Laying Out Pan Joist Floors (cont.)
- Typically no stirrups are used in joists
- Reducing Forming Costs
- Use constant joist depth for entire floor
- Use same depth for joists and beams (not always
possible)
25Pan Joist Floor Systems
- Distribution Ribs
- Placed perpendicular to joists
- Spans lt 20 ft. None
- Spans 20-30 ft. Provided a midspan
- Spans gt 30 ft. Provided at third-points
- At least one continuous 4 bar is provided at top
and bottom of distribution rib. - Note not required by ACI Code, but typically
used in construction
26Member Depth
- ACI provides minimum member depth and slab
thickness requirements that can be used without a
deflection calculation (Sec. 9.5 ACI 318) - Useful for selecting preliminary member sizes
27Member Depth
- ACI 318 - Table 9.5a
- Min. thickness, h (for beams or ribbed one-way
slab) - For beams with one end continuous L/18.5
- For beams with both ends continuous L/21
- L is span length in inches
- Table 9.5a usually gives a depth too shallow for
design, but should be checked as a minimum.
28Member Depth
ACI 318-99 Table 9.5a
29Member Depth
- Rule of Thumb
- hb (in.) L (ft.)
- Ex.) 30 ft. span -gt hb 30 in.
- May be a little large, but okay as a start to
calc. DL - Another Rule of Thumb
- wDL (web below slab) 15 (wSDL wLL)
- Note For design, start with maximum moment for
beam to finalize depth. - Select b as a function of d
- b (0.45 to 0.65) (d)
30Pattern Loads
- Using influence lines to determine pattern loads
- Largest moments in a continuous beam or frame
occur when some spans are loaded and others are
not. - Influence lines are used to determine which spans
to load and which spans not to load.
31Pattern Loads
- Influence Line graph of variation of shear,
moment, or other effect at one particular point
in a structure due to a unit load moving across
the structure.
32Pattern Loads
- Quantitative Influence Lines
- Ordinate are calculated (exact)
MacGregor (1997)
33Pattern Loads
- Qualitative Influence Lines
- Mueller-Breslau Principle
- Used to provide a qualitative guide to the shape
of the influence line
34Pattern Loads
- Qualitative Influence Lines (cont.)
- For moments
- Insert pin at location of interest
- Twist beam on either side of pin
- Other supports are unyielding, so distorted shape
may be easily drawn. - For frames, joints are assumed free to rotate,
assume members are rigidly connected (angle
between members does not change)
35Qualitative Influence Lines
The Mueller-Breslau principle can be stated as
follows If a function at a point on a structure,
such as reaction, or shear, or moment is allowed
to act without restraint, the deflected shape of
the structure, to some scale, represents the
influence line of the function.
36Pattern Loads
Qualitative Influence Lines
Fig. 10-7 (b,f) from MacGregor (1997)
37Pattern Loads
- Frame Example
- Maximize M at point B.
- Draw qualitative influence lines.
- Resulting pattern load
- checkerboard pattern
38Pattern Loads
- Arrangement of Live Loads (ACI 318-02, Sec.
8.9.1) - It shall be permitted to assume that
- The live load is applied only to the floor or
roof under consideration, and - The far ends of columns built integrally with the
structure are considered to be fixed.
39Pattern Loads
- Arrangement of Live Loads ACI 318-99, Sec.
8.9.2 - It shall be permitted to assume that the
arrangement of live load is limited to
combinations of - Factored dead load on all spans with full
factored live load on two adjacent spans. - Factored dead load on all spans with full
factored live load on alternate spans.
40MomentEnvelopes
The moment envelope curve defines the extreme
boundary values of bending moment along the beam
due to critical placements of design live loading.
Fig. 10-10 MacGregor (1997)
41Approximate Analysis of Continuous Beam and
One-Way Slab Systems
- ACI Moment and Shear Coefficients
- Approximate moments and shears permitted for
design of continuous beams and one-way slabs - Section 8.3.3 of ACI Code
42Approximate Analysis of Continuous Beam and
One-Way Slab Systems
- ACI Moment and Shear Coefficients - Requirements
- Two or more spans
- Approximately Equal Spans
- Larger of 2 adjacent spans not greater than
shorter by gt 20 - Uniform Loads
- LL/DL 3 (unfactored)
43Approximate Analysis of Continuous Beam and
One-Way Slab Systems
- ACI Moment and Shear Coefficients - Requirements
( cont.) - Prismatic members
- Same A, I, E throughout member length
- Beams must be in braced frame without significant
moments due to lateral forces - Not state in Code, but necessary for coefficients
to apply. - All these requirements must be met to use the
coefficients!
44Approximate Analysis of Continuous Beam and
One-Way Slab Systems
ACI Moment and Shear Coefficients Methodology
wu Total factored dead and live load per
unit length Cm Moment coefficient Cv Shear
coefficient ln Clear span length for span in
question for Mu at interior face of exterior
support, Mu and Vu ln Average of clear span
length for adjacent spans for Mu at interior
supports
45Approximate Analysis of Continuous Beam and
One-Way Slab Systems
- ACI Moment and Shear Coefficients
- See Section 8.3.3 of ACI Code
46Homework
ETABS Problem. (Due 10/4/02) It will be up
later this afternoon.