SO2 Precursor Gas Monitoring Training Overview - PowerPoint PPT Presentation

1 / 17
About This Presentation
Title:

SO2 Precursor Gas Monitoring Training Overview

Description:

Validation of SO2 and sulfate modeling predictions. Long term trends analysis ... Fluoresces in a fashion similar to SO2 when exposed to UV light ... – PowerPoint PPT presentation

Number of Views:180
Avg rating:3.0/5.0
Slides: 18
Provided by: lewiswe
Category:

less

Transcript and Presenter's Notes

Title: SO2 Precursor Gas Monitoring Training Overview


1
SO2 Precursor Gas Monitoring Training Overview
  • Lewis Weinstock
  • Solomon Ricks, U.S. EPA
  • Office of Air Quality Planning and Standards

2
Outline
  • Methodology
  • Field test results
  • Responses to Calibrations
  • Burdens Creek SO2 Frequency Distribution
  • Instrument Operations
  • Summary

3
Why measure trace levels of SO2
  • Objectives
  • Emission strategy development
  • Effectiveness of reduction strategies
  • Validation of SO2 and sulfate modeling
    predictions
  • Long term trends analysis
  • Health effect studies

Need highly-sensitive ambient monitors deployed
around these areas to determine CAIRs effect on
SO2 and related species.
4
Trace Level Sampling Challenges (SO2)
  • Performance challenges
  • Lower noise for reduced LDL/MDL
  • Reduced zero and span drift
  • Increased rejection of interferences
  • Trace level modifications
  • Special band-pass filter to increase NO rejection
  • Improved light baffling to reduce stray light
  • More powerful UV source lamp
  • Higher detector sensitivity
  • Longer optical bench

5
Methodology (UV Light Path)
SO2 hv214nm SO2 SO2
SO2 hv330nm
6
Methodology (General Schematic)
General Diagram of a Precursor Gas SO2 Analyzer
7
Currently Available Trace-Level SO2 Options
Teledyne-API 100EU EQSA-0495-100
Thermo Electron 43C-TLE EQSA-0486-060 (new model
43i-TLE)
Ecotech EC9850T EQSA-0193-092
8
Testing Results FieldApril 2006
9
(No Transcript)
10
Recertified Environics calibrator
11
Recertified Environics calibrator
?
12
Burdens Creek Ambient Concentrations
Span Level
Precision Level
13
Burdens Creek Ambient Concentrations
14
Thermo 43C-TLE Diagnostic Parameters (5-11-07)
15
Instrument Operation
16
Interferences
  • Hydrocarbons
  • Fluoresces in a fashion similar to SO2 when
    exposed to UV light
  • Removed through the hydrocarbon kicker
  • Nitrogen oxide
  • NO fluoresces in a spectral range close to SO2
  • Band pass filter enhances NO rejection

17
SO2 Response due to NO interference