Title: Sampling Issues for Optimization in Radiotherapy


1
Sampling Issues for Optimization in Radiotherapy
  • Michael C. Ferris
  • R. Einarsson
  • Z. Jiang
  • D. Shepard

2
Radiation Treatment Planning
  • Cancer is the 2nd leading cause of death in U.S.
  • Only heart disease kills more
  • Expected this year in the U.S. (Amer. Cancer
    Soc.)
  • New cancer cases 1.33 million (gt 3,600/day)
  • Deaths from cancer 556,500 (gt 1,500/day)
  • New brain/nerv. sys. cancer cases gt 18,300 (gt
    50/day)
  • Cancer treatments surgery, radiation therapy,
    chemotherapy, hormones, and immunotherapy

3
Radiation As Cancer Treatment
  • Interferes with growth of cancerous cells
  • Also damages healthy cells, but these are more
    able to recover
  • Goal deliver specified dose to tumor while
    avoiding excess dose to healthy tissue and
    at-risk regions (organs)

4
Conformal Radiotherapy
  • Enhanced conformation allows for greater dosages
    of radiation to reach the target volume
    (conformal shaping) while minimizing the dose
    delivery to surrounding normal tissues (conformal
    avoidance)

5
(No Transcript)
6
Conformal Radiotherapy
7
Delivery types
  • Particle beam (proton)
  • Cyclotron (expensive, huge, not marketed)
  • Cobalt60 based (photon)
  • Gamma Knife (stereotactic, shots of radiation)
  • Linear accelerator (x-ray)
  • Widely available
  • Conformal, IMRT, IMAT

8
Linac Based Radiosurgery
  • Advantages
  • Cost/space
  • Disadvantages
  • Machine time
  • Extensive QA procedures
  • Reliability issues

9
Example
10
Notation
Dose delivered by a beam of unit weight to voxel
(i,j,k) by an angle A
11
Beams eye view
  • Beams eye view at a given angle is determined
    based upon the beam source that intersects the
    tumor
  • The view is constructed using a multi-leaf
    collimator

12
Dose Distribution
  • Experts determine an ideal dose distribution for
    a particular target
  • Covers target (tumor)
  • Limits radiation to healthy/at-risk regions
  • Delivery plan optimization problem

13
Delivery Plan
plus some integrality constraints
14
Mixed Integer Approach
15
Dose/Volume Constraints
  • e.g. (Langer) no more than 5 of region R can
    receive more than U Gy

16
Alternative approaches
  • Conditional Variance at Risk (CVAR)
  • Convex form that approximates DVH constraints
  • Can use piecewise linearization and adaptive
    penalty parameters
  • Alternatively use standard LP
  • P/L approach used in this work

17
Wedges
  • A metallic wedge filter can be attached in front
    of the collimator.
  • It attenuates the intensity of radiation in a
    linear fashion from one side to other.
  • Particularly useful for a curved patient surface
  • 5 positions considered Open, North, East,
    South, and West.

18
Mixed Integer Approach
19
Wedge effect on dose distribution
Open Beam
East Wedge
20
Conformal Therapy
  • Conventional treatment
  • Beams eye view (collimator shaping)
  • Multiple angles (choose subset)
  • Wedges (modify intensity over field)
  • Non-coplanar beams (choose which planes)
  • Avoidance (upper bounds)
  • Homogeneity, conformality
  • Dose/volume constraints

21
IMRT



  • Beam collection of pencils
  • Intensity maps -gt deliverable shapes -gt
    intensities of shapes
  • Limit number of deliveries
  • Optimize intensities and shapes concurrently
  • Arc based delivery

22
Commonalities
  • Target (tumor)
  • Regions at risk
  • Maximize kill, minimize damage
  • Homogeneity, conformality constraints
  • Amount of data, or model complexity
  • Mechanism to deliver dose

23
Assumptions/Setting
  • Dose calculation via Monte Carlo
  • Objective is truth we really do want to
    minimize it
  • Limit discussion to beam angle selection ideas
    are perfectly generalizable
  • Limit planning tool to 3DCRT via MIP because we
    are nearby Europe

24
(No Transcript)
25
Remarks
  • CPLEX 9.0 used, tight tolerances
  • Branch/Bound/Cut code
  • LP relaxation solved using dual simplex (small
    samples) and barrier method (large samples)
  • Terma may add sparsity, CPLEX removes dense
    columns in factor

26
Problems
  • Large computational times
  • Large variance in computing times
  • 5000-12500 sec (for 60,000 voxel case)
  • Ineffective restarts (what if trials?)
  • Large amounts of data
  • Try sampling of voxels (carefully)

27
(No Transcript)
28
(No Transcript)
29
Naïve sampling fails
  • Normal tissue
  • Many more voxels available
  • Streaking effects
  • Use 5x sample on 2nd largest structure
  • Small structures
  • Minimum sample size
  • Homogeneity/min/max on PTV
  • 2x sample on PTV, rind sampling
  • Large gradients on OARs
  • 2x sample on OARs
  • Need adaptive mechanism

30
(No Transcript)
31
(No Transcript)
32
(No Transcript)
33
(No Transcript)
34
Time/quality tradeoff
  • Not really satisfactory
  • Split up problem into two phases
  • Find a reduced set of angles at coarse sampling
  • Optimize with reduced set of angles with finer
    sample
  • Reduced angle problem much faster
  • But doesnt identify angle set well

35
(No Transcript)
36
Multiple samples
  • Generate K instances at very coarse sampling rate
  • Use histogram information to suggest promising
    angles
  • How many? (e.g. K10)
  • How to select promising angles? (frequency gt 20)

37
Full Objective Value
  • gt20 scheme may lose best solution
  • Can calculate the objective function with
    complete sample cheaply from solution of sampled
    problem
  • Use extra information in 2 ways
  • Select only those angles that appear in the best
    full value solutions
  • Refine samples in organs where discrepancies are
    greatest

38
(No Transcript)
39
Three Phase Sampling
  • Reduce solution time without compromising quality
  • Phase I
  • Sample 10 times at low rate to predict angles to
    use
  • Each structure sampled proportionally with
    largest structure sample limited
  • Determine angles used in best few solutions
  • Phase II
  • Increase sample rate, using only proposed angles
  • Phase III
  • Increase sample rate, fix angles and wedge
    orientations

40
Phase I
  • Must be very fast to be useful
  • LP relaxation much quicker (allowing larger
    sample rates) and time variance much smaller
  • But too many angles suggested
  • Utilize summed weight information to rank angles
    over complete set

41
Drawbacks
  • Weight values not necessarily correlated to
    usefulness
  • Sample objective is underestimator, and provides
    little information
  • Utilize this procedure to do gross reduction,
    followed by Phase II to refine angles further

42
Sampling Process
  • Determine initial sample size
  • Phase I use all angles
  • 10 sample LPs solutions determine
  • Phase II use reduced set of angles
  • 10 sample MIPs determine
  • Phase III use further reduced set
  • Increase sample rate, solve single MIP

43
Initial sample size
  • Choose trial sample size K
  • Solve LPrelax(K)
  • Double K until Time(LPrelax(2K)) unacceptable
  • If
    unacceptable, ERROR(more time)
  • Value(K) is full sample objective value from
    sample size K optimization

44
Phase III
  • Phase II may make all decisions so problem could
    be an LP for example
  • Sample at fine enough rate to satisfy industry
    requirements
  • Clean up phase!

45
Pelvis case
  • 3K prostate, 1.5K bladder, 1K rectum, 557K normal
  • Time for full problem 12.5K secs
  • Time Phase I 16 secs
  • Time Phase II 100 secs
  • Time Phase III 10 secs
  • Solution 40, 80, 150, 240, 270, 300

46
(No Transcript)
47
(No Transcript)
48
Pancreas case
  • 6K pancreas, 515 cord, 9K ltt, 6K rtt, 54K liver,
    502K normal
  • Time for full problem 1200 secs
  • Time Phase I 2 secs
  • Time Phase II 12 secs
  • Time Phase III 80 secs
  • Solution 80, 290, 350 ( wedges)

49
(No Transcript)
50
(No Transcript)
51
Breast case
  • 39K ptv, 13K heart, 11K rind breast, 71K normal
  • Time Phase I 18 secs
  • Time Phase II 11 secs
  • Time Phase III 2 secs
  • Solution 130, 290 ( wedges)

52
(No Transcript)
53
(No Transcript)
54
Head/Neck case
  • 2K ptv, 51K l/rcerebrum, 2K brainstm, 14K
    cerebellum, others (15-833)
  • Time for full problem 2542K secs
  • Time Phase I 10 secs
  • Time Phase II 22 secs
  • Time Phase III 2 secs
  • Solution 30, 140, 230 ( wedges)

55
(No Transcript)
56
Comparison (Pelvis case)
  • Normal Strategy
  • 41 sample, 36 angles
  • 1307 secs
  • Solution dvh shown
  • Prostate (blue),bladder (red), rectum
    (black),normal(green)
  • Three Phase Strategy
  • Phase I (9 sample, 36 angles)
  • 76 secs total
  • Phase II (21 sample, 11 angles)
  • 5 secs
  • Phase III (41 sample, 6 angles)
  • 3 secs
  • Solutions identical
  • angles 40,90,150,240,270,300

57
Extensions
  • Within 3DCRT
  • Wedges, energy levels, non-coplanar beams all
    optimized concurrently
  • Tomotherapy
  • IMAT
  • IMRT
  • Larger and more complex cases