Title: Molding PDMS Channels and an Embedded Detector Chamber


1
Molding PDMS Channels and an Embedded Detector
Chamber
  • Takaya Ueda
  • MASc Candidate
  • Simon Fraser University
  • July 25, 2006

2
Overview
  • Background
  • Objective
  • Motivation
  • Design
  • Results
  • Conclusion
  • Current work

3
Background
  • Microfluidics
  • Delivering liquid through narrow channels (µm
    diameter)
  • Small sample and chemical volume
  • Biomedical applications
  • e.g. Single cell testing and analysis

4
Background
  • SU-8
  • Negative photoresist
  • Solid after cross-linking
  • Poly-dimethylsiloxane (PDMS)
  • Silicone elastomer
  • Applied as mold
  • Optically transparent once cured

5
SU-8 and PDMS
  • Using SU-8 and PDMS together can rapidly
    fabricate multiple copies of a structure
  • Pattern structures with SU-8
  • Pour PDMS on top of the SU-8
  • Peal off the PDMS after cure
  • Repeat 1-3 as necessary
  • Rapid processing enables fabrication of low cost
    disposable devices

6
Motivation
  • Cells react to laser light or drugs
  • Reaction causes fluorescence
  • Photo-multiplier tube (PMT) used to detect and
    analyze the light
  • Problem
  • PMT and laser are large and expensive compared to
    the channels

7
Final Objective
  • Fabricate a single cell analysis system for
    fluorescence detection
  • With integrated
  • Photo-diode to replace the PMT
  • LED to replace the laser

8
Current Objective
  • Fabricate
  • 50 µm diameter channels
  • Photo-detector mount
  • Both fabricated by molding using SU-8 and PDMS

9
Design Overview
10
Channel Design
11
Results
  • Successful fabrication of SU-8 channel and
    detector mounts
  • Problems with air bubbles in PDMS
  • Air bubbles affect transparency of PDMS to the
    eye, photo-diode, and LED

SU-8 Channels SU-8 Detector Mount
PDMS Channel
12
Conclusion
  • Successful fabrication of the SU-8 structures
  • PDMS process must be improved to eliminate air
    bubbles to yield usable devices

13
Current Work
  • PDMS results have improved because of better
    processing
  • Currently researching world-to-chip electrical
    connections with PDMS

14
Questions?