ATEX Zone 2/22 Launch Overview (M-Series, iPC-Series

1 / 21
About This Presentation
Title:

ATEX Zone 2/22 Launch Overview (M-Series, iPC-Series

Description:

ATEX Zone 2/22 Launch Overview (M-Series, iPC-Series & nPC300) Ralph Damato VP Product Management – PowerPoint PPT presentation

Number of Views:19
Avg rating:3.0/5.0
Slides: 22
Provided by: rda96

less

Transcript and Presenter's Notes

Title: ATEX Zone 2/22 Launch Overview (M-Series, iPC-Series


1
ATEX Zone 2/22Launch Overview(M-Series,
iPC-Series nPC300)
  • Ralph DamatoVP Product Management

2
ATEX Summary
In a global society the need to adhere to
multiple compliance standards is growing.
Nematron has traditionally supplied UL Class I
Division 2 hazardous location approvals for most
of our Industrial Monitors and PCs. However the
same customers that were content with this
certification are now selling to Europe and other
parts of the world. These other areas of the
world demand a different set of certifications.
Therefore we are proud to announce the
availability of ATEX Zone 2 and 22 approved
Industrial Monitors and PCs. Several changes and
extensive testing were required to obtain this
certification. These new offerings will allow you
to offer a more global product portfolio, while
proudly being made in the USA!
3
Table of Contents
  • Slide
  • ATEX Product Overview 4
  • ATEX M-Series Monitors 5
  • ATEX iPC-Series Computers 6
  • ATEX nPC300 Computers 7
  • Overall Unit Specifications 8
  • Product Features Benefits 9
  • ATEX Markings 10
  • Overall Conditions for Safe Use 12
  • Zone 2 Specific Conditions for Safe Use 13
  • Zone 22 Specific Conditions for Safe Use 14
  • Target Markets Applications 15
  • ATEX Pricing and Ordering Info 16
  • Release Schedule 17
  • ATEX Competitive Comparisons 18
  • Product Training and Demos 19
  • Closing Sales Notes 20

4
ATEX Product Overview
  • ATEX Zone 2/22 approved units include
  • All current M-Series Monitors (includes M1500SRT)
  • All current iPC-Fanless units (includes nPC300,
    Zone 2 only)
  • All current iPC-Series units (includes nPC300,
    Zone 2 only)
  • Special Configurations with -ATEX at the end of
    the Order Number
  • ONLY appropriately marked units are approved for
    ATEX Zone 2/22 installations
  • Must be built and marked at the Nematron
    production facility
  • Only available with the following options
    pre-installed
  • Isolated 24 VDC option (-DC, not currently
    offered in most M-Series monitors)
  • Solid State drive options . . . Non-Rotating
    Drives Only
  • Special high temperature non-porous gaskets
  • Very strict Special Conditions for Safe Use
  • As explained in the certificate DEMKO 14 ATEX
    1374X
  • End user and/or OEMs responsibility to adhere to
    these conditions
  • Also approved for UL ANSI/ISA 12.12.01 (Class I
    Division 2)

5
ATEX M-Series Monitors
  • Includes
  • M1200T (12, SVGA)
  • M1500T (15, XGA)
  • M1500SRT (15 Sunlight Readable, XGA)
  • M1700T (17, SXGA)
  • M1900T (19, SXGA)
  • M2200WT (22 Widescreen, WSXGA)
  • 5-wire Analog Resistive Touchscreen Only
  • eGalax (EETI) touchscreen controller and driver
    only
  • Elographics controller not available nor allowed
    in ATEX variations
  • Isolated 24 VDC internal power supply (-DC
    option)
  • New option for M1200T, M1500T, M1700T, and M1900T
  • Already available in M1500SRT and M2200WT
  • Choice of IP66 front panels
  • Powder coated Aluminum (with or without Logo)
  • Machined Stainless Steel

6
ATEX iPC-Series Computers
  • Includes
  • iPC1200T (12, SVGA)
  • iPC1500T (15, XGA)
  • iPC1700T (17, SXGA)
  • iPC1900T (19, SXGA)
  • 5-wire Analog Resistive Touchscreen Only
  • eGalax (EETI) touchscreen controller and driver
    only
  • Elographics controller not available nor allowed
    in ATEX variations
  • Processor choices include
  • ATOM N2800 (fanless)
  • Celeron P4500, i5, and i7 (requires fansink)
  • Solid State Drive Options only (no rotating
    drives allowed)
  • Isolated 24 VDC internal power supply (-DC
    option)
  • Choice of IP66 front panels

7
ATEX nPC300 Computers
  • Processor choices include
  • ATOM N2800 (fanless)
  • Celeron P4500, i5, and i7 (requires fansink)
  • Solid State Drive Options only (no rotating
    drives allowed)
  • Isolated 24 VDC internal power supply (-DC
    option)
  • Not approved for Zone 22 Installations unless
    completely installed within an ATEX Zone 22
    approved enclosure
  • For all other technical specifications consult
    the datasheet

8
Overall Unit Specifications
  • Environmental Specifications
  • Operating
  • Temperature . . . 0 C to 55 C
  • Humidity . . . . . . 20 to 80 RH
  • Shock . . . . . . . . 15g peak, 11msec
  • Vibration . . . . . . 0.006 peak to peak, 1g max
    5-2000 Hz
  • Altitude . . . . . . . Sea level to 10,000 ft.
  • NEMA 4/4X/12, IP66 (does not apply to nPC300)
  • DC Input
  • Isolated 24 VDC only
  • Consult datasheet for appropriate range and
    amperage
  • Typical Power Rating
  • With all I/O ports functional
  • To be utilized when sizing an enclosure
  • Consult datasheet for appropriate rating

9
Features and Benefits
  • Can be installed in European Hazardous Locations
  • Zone 2 (Gas, Vapors, and Mist)
  • Zone 22 (Dust)
  • Ideal for Oil Gas, Chemical, Pharmaceutical
    Applications
  • ANSI/ISA 12.12.01 (formerly UL 1604) Hazardous
    Locations Approved (Class I Division 2)
  • Approved for United States and Canada
  • Ideal for Oil Gas, Chemical, Pharmaceutical
    Applications
  • Intel Solid State Drives
  • High Reliability
  • 5-year Part warranty
  • Reliable and Fast Data Transfers
  • Power down protection to protect data

10
ATEX Markings for iPC-Series and M-Series
  • The following markings must appear on the -ATEX
    variations of the iPC-Series and M-Series units
    in order to be ATEX Zone 2/22 approved
  • These markings can only be applied at time of
    production
  • Will appear on the product ID label
  • A one page explanation of what all these symbols
    mean is available by clicking this link
  • Nematron ATEX Markings Explained

II 3G Ex ic nA IIC T4 Gc IP66II 3D Ex tc IIIC
T67C Dc IP660C TAMB 55CCert DEMKO
14 ATEX 1374X
11
ATEX Markings for nPC300
  • The following markings must appear on the -ATEX
    variations of the nPC300 units in order to be
    ATEX Zone 2 approved
  • These markings can only be applied at time of
    production
  • Will appear on the product ID label
  • nPC300 is not Zone 22 approved
  • A one page explanation of what all these symbols
    mean is available by clicking this link
  • Nematron ATEX Markings Explained
  • The nPC300 is not an ATEX Zone 22 approved
    unit, however it can be contained inside an
    enclosure for use in Zone 22 installations

II 3G Ex nA IIC T4 Gc 0C TAMB 55CCert
DEMKO 14 ATEX 1374X
12
Overall Conditions for Safe Use
  • Conditions for Safe Use are listed in the ATEX
    certificate
  • DEMKO 14 ATEX 1374X
  • Available at http//www.nematron.com/atex/demko_13
    74x.pdf
  • User Manual for each product also has this
    information documented
  • Units with front panels are not intended for high
    impact installations (does not apply to nPC300)
  • ATEX requires 2 levels of testing
  • 0.2 or 0.4 meter drop of a spherical weight onto
    the front surface after heat aging
  • Nematron units 100 pass the lower 0.2 meter drop
    test but do not meet the 0.4 meter drop test
  • The 0.2 meter drop is a harder test to pass than
    the UL Class I Division 2 test that our units
    currently meet
  • Transient protection shall be provided that is
    set at a level not exceeding 140 of the peak
    rated voltage at the supply terminals to the unit
  • Because these are Open construction units (have
    vents and are not IP54 sealed) they need to be
    installed within ATEX approved enclosures
  • Enclosure must utilize a tool removable cover,
    door, or panel
  • Inside enclosure must maintain a Pollution Degree
    2 environment per IEC/EN60664-1
  • Normally, only non conductive pollution occurs.
    Occasionally however a temporary conductivity
    caused by condensation may be expected
  • No dust, no conductive vapors, gases, or fumes,
    and condensation must be controlled and kept to
    minimum level

13
Zone 2 Specific Conditions for Safe Use
  • Zone 2 (Group IIC) is for installations where
    gases, vapors, and mist may be present
  • Group IIC also includes group IIA and IIB
  • IIA, IIB, and IIC define the types of gases
  • In any environment that is NOT Pollution degree
    2, the unit must be mounted in an ATEX approved
    IP64 or better enclosure per IEC/EN 60079-15
    (also applies to nPC300)
  • Examples are outdoor, hose down areas, or areas
    where fumes are present
  • Must maintain a Pollution Degree 2 environment
    per IEC/EN60664-1 inside the enclosure
  • Enclosure must utilize a tool removable cover,
    door, or panel
  • Transient protection shall be provided that is
    set at a level not exceeding 140 of the peak
    rated voltage at the supply terminals to the unit
  • In any environment that is already Pollution
    degree 2, the unit must be mounted in an ATEX
    approved IP54 or better enclosure per IEC/EN
    60079-15 (also applies to nPC300)
  • Examples may be indoor areas, clean rooms, or
    areas with tightly controlled environments
  • Must maintain a Pollution Degree 2 environment
    per IEC/EN60664-1 inside the enclosure
  • Enclosure must utilize a tool removable cover,
    door, or panel
  • Transient protection shall be provided that is
    set at a level not exceeding 140 of the peak
    rated voltage at the supply terminals to the unit

14
Zone 22 Specific Conditions for Safe Use
  • Zone 2 (Group IIIC) is for installations where
    conductive dust may be present
  • Group IIIC also includes group IIIA (conductive
    flyings) and IIIB (non-conductive dust)
  • For any IIIC installation (includes IIIA and
    IIIB) the touchscreen on any iPC-Series or
    M-Series must be wiped down with a damp cloth
    prior to use
  • To prevent any electrostatic discharges from
    causing ignition of combustible materials.
  • For any IIIC installation (includes IIIA and
    IIIB) the brightness adjustment buttons on the
    M1500SRT must be wiped with a damp cloth prior to
    use
  • To prevent any electrostatic discharges from
    causing ignition of combustible materials.
  • Any environment that is considered IIIC requires
    the use of an IP64 or better enclosure per IEC/EN
    60079-15 (also applies to nPC300 )
  • Examples are outdoor, hose down areas, or areas
    where fumes are present
  • Any environment that is considered IIIA or IIIB
    requires the use of an IP54 or better enclosure
    per IEC/EN 60079-15 (also applies to nPC300 )
  • Examples may be indoor areas, clean rooms, or
    areas with tightly controlled environments
  • The nPC300 is not an ATEX Zone 22 approved
    unit, however it can be contained inside an
    enclosure for use in Zone 22 installations

15
Target Markets and Applications
  • Many different markets and applications can
    utilize the ATEX approved Industrial Monitors
    and Computers
  • Chemical Processing
  • Oil Gas
  • SCADA
  • Food Pharmaceuticals
  • Pulp Paper
  • Key Application Advantages
  • Petro-Chemical
  • ATEX Zone 2 approved
  • Class I II Division 2 Approved
  • 24 VDC Input
  • Food Pharmaceuticals
  • ATEX Zone 2/22 approved
  • Class I II Division 2 Approved
  • 24 VDC Input

16
ATEX Pricing and Ordering Info
  • Pricing is contained in the ATEX Price List
    Addendum (April 2015)
  • Click here to get price List
  • Ordering Information is contained in the
    datasheets for each model
  • Click here to go to the ATEX Product Page
  • Then click on the tab for Ordering Information
  • Also contained in the datasheet link on this page

17
ATEX Release Schedule
  • DEMKO Certificate Received . . . . . . . . . .
    April 1, 2015
  • All testing and approvals competed!
  • Press Release Distribution to Pubs . . . . April
    23, 2015
  • Release Package Distribution . . . . . . . . .
    April 23, 2015
  • Includes datasheets, price list, press release,
    picture, launch presentation
  • Production Units Available . . . . . . . . . . .
    April 23, 2015
  • Includes all options and accessories
  • Special gaskets and all required material
    available

18
ATEX Competitive Comparisons
  • What Competitors?
  • There are very few Open construction units that
    have ATEX Zone 2/22 approvals
  • Open construction means there are vents and
    openings, but enough to make the unit operator
    safe. The use of an enclosure is required to
    protect from dust, gas, vapors, and fumes
  • Allows for customization of the enclosure and
    inclusion of other devices
  • Open construction allows for a more cost
    competitive offering
  • Closest Competition is PepperalFuchs 22 Monitor
  • Only approved for indoor Zone 2 locations
    (Pollution Degree 2 environments only)
  • Also Open Construction that needs to be in an
    enclosure
  • More expensive than the Nematron M2200WT-DC-ATEX
  • Competitors may state ATEX Zone 2 or 22 approved,
    but unless they have a certificate from a
    certified ATEX approved test lab it is highly
    suspicious and questionable
  • ATEX can be a self declaration but many
    installations demand official documentation
  • Ask for proof of compliance
  • Use our official DEMKO certificate as leverage to
    your customer(s)

19
Product Training Demos
  • Specific product training is not currently
    scheduled
  • Contact your Nematron Regional Sales Manager or
    sales_at_nematron.com if you are interested in
    setting up a training session or webinar, we will
    be glad to assist
  • ATEX Demo Unit Availability
  • ATEX marked units are available for purchase as
    demos, since these are higher priced units with
    special compliance, markings, and materials a 50
    discount will be offered for a limited time
  • Only one per distributor organization
  • Discount only available through the end of 2015
  • Note these are 24 VDC powered only, making it
    more difficult to demo. AC power supplies for
    these units are not offered.
  • Our standard units can be utilized to demo the
    product form, fit, and performance will be
    identical
  • There is a very limited number of ATEX demo units
    available, contact your Nematron Regional Sales
    Manager or sales_at_nematron.com for more details if
    one is absolutely required

20
Closing Sales Notes
  • Great price!
  • Open construction allows for a much more
    competitive price
  • Easier integration with other devices in the
    enclosure
  • Documented proof of ATEX approvals in certificate
    DEMKO 14 ATEX 1374X
  • Issued by DEMKO, an ATEX certified test lab
  • Official certificate http//www.nematron.com/ate
    x/demko_1374x.pdf
  • Special Conditions for Safe Use must be adhered
    to for ATEX Zone 2/22 applications
  • M-Series Monitors
  • M1200T, M1500T, M1700T, and M1900T
  • M2200WT
  • M1500SRT
  • Powder-coated Aluminum and Stainless Front Panel
    options
  • iPC-Series Industrial PCs
  • iPC1200T, iPC1500T, iPC1700T, and iPC1900T
  • Fanless ATOM N2800 up to i7 processors available
  • Powder-coated Aluminum and Stainless Front Panel
    options
  • nPC300 node PC
  • Fanless ATOM N2800 up to i7 processors available
  • Can be mounted to the rear of the M-Series
    monitors with custom bracket (sold separately)

21
(No Transcript)
Write a Comment