Title: Establishing Air Cleanup Levels Under WAC 173340750
1Establishing Air Cleanup Levels Under WAC
173-340-750
- Pete Kmet, P.E.
- Department of Ecology
- Toxics Cleanup Program
- (360) 407-7199 pkme461_at_ecy.wa.gov
2Establishing Air Cleanup Levels under WAC
173-340-750
3Establishing Air Cleanup Levels under WAC
173-340-750
- Sites needing to establish air cleanup levels
- SSRA for nonpotable groundwater
- SSRA for soil
- Emission limits
- Required by Ecology
- Note Concentrations caused by process emissions
and off site sources do not need to be addressed.
4Establishing Air Cleanup Levels under WAC
173-340-750
- Cleanup Standard Concentration
- Point of Compliance
- ARARs
- Must use reasonable maximum exposure
- (defined as residential for most sites)
5Establishing Air Cleanup Levels under WAC
173-340-750
6Establishing Air Cleanup Levels under WAC
173-340-750
7Establishing Method B Air Cleanup Levels under
WAC 173-340-750(3)
8Establishing Method B Air Cleanup Levels under
WAC 173-340-750(3)
9Establishing Method B Air Cleanup Levels under
WAC 173-340-750(3)
10Establishing Method C Air Cleanup Levels under
WAC 173-340-750(4)
- Method C can be used for industrial properties
and manholes and utility vaults. - Method C can also be used where all practicable
methods of treatment have been used
institutional controls established and one of
the following conditions exist - Method A or B below technically possible
concentrations - Method A or B below area background
- Method A or B poses greater overall threat
11Establishing Method C Air Cleanup Levels under
WAC 173-340-750(4)
- Essentially the same as Method B except for
- Somewhat less stringent assumptions are used in
the calculation of a cleanup level - The allowable cancer risk is higher
- (1 X 10-5)
12Establishing Air Cleanup Levels under WAC
173-340-750
- TPH Mixtures
- Must evaluate noncarcinogenic effects of TPH
Mixture as a whole - Must evaluate ARARs, noncarcinogenic and
carcinogenic effects for individual TPH
components - Need either measured or predicted air composition
including TPH fractions and components
13Establishing Air Cleanup Levels under WAC
173-340-750
- Point of Compliance
- Throughout the site for most sites
- Industrial properties--up to property boundary
14Establishing Air Cleanup Levels under WAC
173-340-750
- Compliance Monitoring
- Soil vapor testing
- Indoor/outdoor air monitoring
- Stack testing
- If no ARAR
- Noncarcinogens use 24 hour average
- Carcinogens use annual average
15Establishing Air Cleanup Standards under WAC
173-340-750
- Summary
- Highlighted key differences
- Described what sites need to establish air
cleanup levels - No Method A air cleanup levels
- Establishing cleanup levels under
- Methods B and C.
- Special considerations for TPH mixtures
- Point of Compliance options