Title: Bits Pilani Solar Power Fencing by Blaze Automation
1www.blazeautomation.com
Security And Surveillance Requirements of BITS
Pilani Hyderabad Campus
Sridhar Ponugupati Chief Executive Officer Blaze
Automation
2- Presentation Outline
- Back Ground / Introduction
- Areas of mutual interest
- a. Perimeter Solar Fencing (Basic, Mid
Range, High security ) - b. IP CCTV Surveillance system
- c. RFID based Access Control system for
student monitoring - d. Central Monitoring Station Equipment
- System Architecture , Specifications and Budget
- Detailed Quotations (will be submitted after
this meeting) - Conclusion
3Fences are first line of defence mechanisms
Why Solar Fencing ?
- Crime and disruption protection through
deterrence. - Reduction of damages through the use of delaying
mechanisms such as fences.
4Perimeter Solar Fencing -- Attributes
- Safety
- Durable
- Convenience to operate
- Weather resistant
- Durable
- Low maintenance
- Spot Alarming
- Multi Sector Monitoring
- Open ended for Expansion
- Flood Lighting control
- Intrusion Detection and Alerting
- through PC application Software.
-
5Solar power fencing -- Principle of Operation
- An electric fence is a barrier that
uses electric shocks to deter animals or people
from crossing a boundary. The voltage of the
shock may have effects ranging from uncomfortable
to painful but not lethal. The charge of pulse
0.3 milli sec is sent through the fence in 1- to
2-second intervals and gets energized to 4000 to
9000 volts.
Advantages of Solar Power Fencing
- Advanced Perimeter protection device
- Non-lethal system
- Does not require any approval from any
Government Department. - System meets ISI and IEC standards of safety.
- Creates a Psychological fear in the mind of
intruder. - System shall not only detect but also deny the
intrusion.
6Categories of Solar Power Fencing systems
- Basic Security Power Fencing
- Mid range Security Fencing with CMS facility and
Flood Light Control - Advanced Perimeter Security System with CCTV
integration
7Basic Security Power Fencing
8Components of a Solar Power Fencing System ---
Basic Version
9Main Components of Solar Fencing System - contd
- Fence Energizer
- Fence Voltage Alarm
- LMLA Battery
- Solar Module
- External Alarm
- Fence accessories
- Earthing mechanism
- Monitoring and Reporting Unit
10(No Transcript)
11(No Transcript)
12Limitation of this model
- No source Detection
- No Flood Light Control
- Requires Lot of manual Intervention
- User need to monitor the health on daily basis
- No much intelligence is incorporated
Conclusion
- Easy to install
- Absolutely low cost
- Provides same level of security when compared to
other models - Requires lot of Manual intervention every day
13Mid range Security Fencing with CMS facility and
Flood Light Control
14Mid Range System Features
- Includes all basic Solar Fencing system
Attributes - User can control the operation of the entire
system from the central unit through CMS software - Identification of the alarm Zone is possible in
this. - Provides the real time health status of the
Fence - Flood Light Control through CMS software
- Provides Reports of Communication and intrusion
15Perimeter Length 6.0 KM (Approximately) Difficul
ties in operating Perimeter
Equipment Fencing, Lighting
etc What if a security alarm is Triggered ?
16Zone 12
Zone 3
Zone 11
Zones Identified by BLAZE
12
Zone 2
Zone 4
Zone 1
Zone 10
Zone 5
Zone 9
Zone 6
Zone 7
Zone 8
17Central Monitoring Unit Features
- It provides a digital control over the System.
- The zone of intrusion will be indicated on the
LCD screen. - Speech dialer and SMS messenger is incorporated
in the system and shall call the stored number
automatically, upon intrusion. - Access to the System shall be through Password
only. - The System parameters (Fence Voltage, Battery
status, Communication status, Alarm status etc..)
can be monitored and changed with the help of a
communication Link with the Monitoring Node kept
at each Energizer by Authorized Administrator
18Central Monitoring Unit Operation Diagram
19Real Time Communication Status of CMS GUI
20Real Time Intrusion Detection System
21Conclusion
- Easy to install
- Absolutely low cost
- Provides same level of security when compared to
other models - Requires very less manual intervention
- Provides efficient Flood Light controlling based
on intrusion. Manual control is also possible. - User can monitor the Health of the Fence in Real
Time. - User can Control the ON and OFF of the System in
Real Time through CMS software.
22Advanced Perimeter Security System with CCTV
integration
Wireless IP Surveillance Solution
23Advanced System Specifications
- Includes all basic Solar Fencing system
Attributes - User can control the operation of the entire
system from the central unit through CMS software - Identification of the alarm Zone is possible in
this. - Provides the real time health status of the
Fence - Flood Light Control through CMS software
- Provides Reports of Communication and intrusion
- PTZ enabled CCTV camera can help in monitoring
the intrusion areas in less than 5 sec. - Ethernet equipment at each Node can help for
further extension of the system.
24- Typical Equipment at Each Zone
- PTZ high Resolution camera
- Solar Fencing Equipment
- CMS software
- When Alarm Triggers
- Central unit will get intimation about the
Intrusion zone and the same will be indicated in
the MIMIC Panel - PTZ cameras will be directed towards the Zone
and user can zoom into the source of intrusion
with high end optical Zoom cameras.
25Zone 12
Zone 3
Zone 11
12 Zones Identified by BLAZE with CCTV
integration
Zone 2
Zone 4
Zone 1
Zone 10
Zone 5
Zone 9
Zone 6
Zone 7
Zone 8
26Budget Requirements for Solar Power Fencing system
- Basic System
- Per KM 5.20 Lakh
- Total Cost 33 36 Lakh including
installation - Mid Range System with CMS and Lighting control
- Per Zone 4.9 Lakh approx
- Total Cost 58.8 62 Lakh with installation
- Advanced system with CCTV surveillance
- Per Zone 11.2 Lakh approx
- Total Cost 134 140 Lakh with installation
27Safety requirements of Solar Power Fencing System
- Fence lines should not lie within 2 m of
telephone lines or within 15 m of power cables. - Fence earthing systems should be positioned at
least 10 m away from any electricity supply earth
pit. - Where the general public has access to the fenced
area, warning notices should be attached to the
fence at intervals no greater than 100 m. - If a fence is in the vicinity of over head power
lines, no fence wire should be higher than 6'6"
above the ground. - An electric fence ground system should not be
connected to any plumbing system, including
disused water pipes or old bore casings, nor
should it be connected to any other grounding
device. - Each energizer should be connected to its own
ground system and this should not be connected to
any other ground system.
28IP Video Surveillance for Campus activity
monitoring
29Traditional DVR System
Coax
Cat 5e
Network Switch
Cat 5e
DVR
30IP Video System
Analog Cameras
IP Cameras
Coax
Encoder
Network Switch
Cat 5e
Cat 5e
Storage
Client Workstation
NVR
31IP Cameras
- Connect directly to Ethernet network
- Wide variety of models available for all
applications
Fixed
Mini-Dome
Pan/Tilt/Zoom
Bullet
32- Most cameras have high resolution available
- 640 X 480 (4 CIF)
- 720 X 480 (D1 )
- MegaPixel IP Cameras are available
- Up to 5 MegaPixels
33IP cameras with megapixel resolution allow for
highly effective digital zoom capability and
virtual pan and tilt functionality
640 X 480 Image
1900 X 1200 Image
34- Power Over Ethernet (IEEE 802.3af)
- Less cabling
- Can be added using injectors (mid-spans)
- Use existing IP switches
35- Various video compression methods are available
- Motion JPEG
- MPEG4
- H.264
- Wavelet
- Most cameras only have one or two types of
compression available
36- The camera can be used as connection device for
other types of data - Alarm Inputs
- Alarm Outputs
- Audio (Bi-Directional)
- RS-232
37- Many models have card slots available for
wireless Ethernet adaptors or local storage - Many options are available for wireless
connection to cameras
38- Most models have built-in motion detection
- Some have built-in video analytics
- Intelligent motion detection
- Abandoned object
39NVR
- Software Solution
- Installed on a non-proprietary server
- Advantages
- Customers can source their own servers,
workstations, and storage devices - Can be less expensive in cases where there are a
large number of cameras being recorded at a low
frame rate - Virtually all IP cameras are supported
- Virtual matrix switch software is available
40- Disadvantages of software NVR
- Can be more difficult to install and service
- Higher total cost in most cases
- Limited integration with access control
- Customers can buy their own servers and storage
41- NVR on proprietary hardware
- Software is pre-installed on hardware provided by
the CCTV manufacturer - Internal or external storage is also usually
provided by the CCTV manufacturer - Advantages
- Easy to design the system
- Easy to install and service
- Many of these types of NVRs can be integrated
with access control systems - User interface may be similar or identical to
DVRs - Well developed suite of features inherited from
DVR technology
42- Disadvantages of proprietary NVR
- Usually support a very limited variety of cameras
- Customers that desire IP surveillance systems may
not want to be locked into proprietary server and
storage hardware
43Large facilities or campus environments
- Server pulls video over network backbone
- Long distance home-run cabling is not required.
44Cameras are widely distributed
- Locations are connected via a WAN
- Recording is done at a central location
45More Applications
- Customer needs high resolution images
- Most surveillance grade IP cameras can provide
higher resolution images than DVR - MegaPixel cameras can provide very high quality
images - Remember that they will require at least 20 times
more storage space than a standard camera - Customers with the future in mind
- Customers with a strong IT department
46Budget for CCTV surveillance along with Recording
hardware Excluding network infrastructure
Fixed 29.5K 13.0 Lakh
Mini-Dome 94.5K 36 42 Lakh
Pan/Tilt/Zoom 143.0K 55 60 Lakh
Bullet 23.0K 11.0 Lakh
For 32 Cameras
47Long Range RFID access control system for Student
activity tracking at the main gate
- System Requirements
- Long Range RFID readers 2 in number
- RFID tags As per the requirement
- Application software Customized as per
the requirements - Budget requirements
-
- Long Range Reader 65.0 K 2 130.0 K
- Cards 50 60 rupee per tag
- Software cost around 100.0 K Estimated
total cost for 1000 students 3.0 Lakh rupee
48Central Monitoring Station Equipment
- For Solar Power Fencing Monitoring and
Commanding Control of the same. - For Perimeter Lighting control and Perimeter
camera monitoring - For CCTV surveillance of the campus
- For Student activity monitoring
- Estimate of the Budget can be prepared if the
above three system configurations are finalized.
49Thank youceo_at_blazeautomation.com Tel 91 40
6457 2220