Title: Chillgard
1Chillgard L Series Refrigerant Monitors
2Chillgard L Series
- The refrigerant monitoring industry leader
- Home of proven, reliablePhotoacoustic Infrared
Technology
3Chillgard L Series
- Photoacoustic sensor is stable and sensitive
- Improved PIR sensing
- Sample system minimizes moving parts, no solenoid
valves or mechanical flow switch - RS-485 Digital Signal Processing
- New advances in micro-machined technology
- Water and Corrosion resistant plastic enclosure
4Chillgard L Series
- Features a new optical bench
- Micro-machined optics
- Significant technological advancement
- Used on all Chillgard LS and LE Gas Monitors
- Improved reliability
- 2-year warranty
- Backwards-compatible with existing units
5Chillgard L Series - Flexibility
- Flexibility to meet
- Refrigerant Monitoring needs
- Remote Signaling and Control
- Power Requirements
- Budget
6Chillgard L Series
- Chillgard LS Refrigerant Monitor
- Economical low level monitoring of refrigerant
gases - Sensor unit with analog and digital output
- Chillgard LC Control Module
- Controls up to 8 Chillgard LS Sensors
- Multiple outputs and relays
- Chillgard LE Refrigerant Monitor
- Combined features of Chillgard LS and LC Gas
Monitors within one enclosure - Combined multi-point sensing and controlling
7Chillgard LS Monitor
- Photoacoustic IR sensor
- Standard gases R123, R134a, R11, R12, R22
- Minimum detection level - 20ppm
- Single-point diffusion or 4-point pumped models
8Chillgard LS
- Compliant with ANSI/ASHRAE 15
- UL approval
- Water- and corrosion-resistant plastic enclosure
- Easy operation, installation and maintenance
- 2-year warranty
9Chillgard LS
- 24 VAC/DC or 110/220 VAC power
- 5 LEDs indicate power, fault and 3 levels of
alarm - 4-20 mA and RS-485 outputs (to Chillgard LC
Controller)
10Chillgard L Series Sensor Board
11Chillgard LS Optional Gases
- R400 and R500 series of refrigerants
- Blends of multiple refrigerants to obtain good
thermodynamic properties in the chiller, with
reduced corrosion and ozone depletion potential. - Includes R404a, R410a, R407c, R507
- Order with custom calibration
- Other refrigerants possible
12Chillgard LS Accessories
- Accessories
- Unit-mounted strobe
- Calibration box
- Remote light towers
- Calibration kits
- Chillgard LC Controller
13Maintenance and Repair
- No moving parts in diffusion-modeChillgard LS
Monitor - Optical bench is field-replaceable for convenient
repair and for detection of a different
refrigerant
14Chillgard LS Optical Bench
pumped bench
diffusion bench
15Chillgard LS Summary
- Low cost refrigerant sensor
- Improved PIR technology
- Easy to install, operate and maintain
- Can be stand-alone or used with Chillgard LC
Controller
16Chillgard LC Control Module
- Capable of controlling up to 8 Chillgard LS
Sensors - Easy-to-use digital display with 4-button keypad
- Provides gas reading, alarm status, calibration
and fault diagnostics - Water- and corrosion-resistant enclosure
17Chillgard LC Features
- 4-20mA and RS-232 output
- 0-10 V point identifier output
- 4 relays - 3 levels of alarm fault
- 85 dB horn, 100 dB horn option
18Chillgard LC Control Board
19Chillgard LS LC
- Twisted pair RS-485, 18 GA wire up to 1000 ft
- Modbus protocol
- LC can communicate with up to 8 single-point LS
monitors, two 4-point LS monitors, or any
combination
20Chillgard LC Wiring
- Home-run communication wiring
- Bus communication wiring
21Powering the Chillgard LS
- Power locally via 24 VAC or DC
- Power locally via 110/220 VAC optional supply
- Power via Chillgard LC Control Module
22Powering the Chillgard LC
- 24 VAC or DC
- 110/220 VAC optional supply
- Can be used to power one Chillgard LS Monitor
23Powering the Chillgard LC
- Transformer version
- Powers Chillgard LC Monitor and up to 5
Chillgard LS Sensors
24Powering Chillgard L Series
RS 485
25Chillgard L Series Power Options
RS 485
With internal 110/220 VAC power supply
With internal 110/220 VAC power supply
26Chillgard L Series Power Options
110/220 V input
4-conductor cable
24 VDC from LC
With internal 110/220 VAC power supply
For 1 sensor module, up to 100 using 18 AWG wire
27Chillgard L Series Power Options
110/220 VAC AVAILABLE
LC transformer version
110/220 V Input
24 VAC
RS 485
24 VAC
RS 485
24 VAC
RS 485
w/internal transformer
Transformer version powers up to 5 diffusion
Chillgard LS Monitors or two 4-point pumped
Chillgard LS Monitors
28Chillgard LC
- Accessories
- Unit mounted strobe
- Remote light towers
- Calibration kits
29Chillgard LC Summary
- Low cost controller
- Controls up to 8 Chillgard LS sensors
- Multiple outputs
- Configurable to meet your needs
- Easy to install, operate and maintain
30Chillgard LE Features
- Combined features of Chillgard LS and LC
products in one enclosure - Combined multi-point sensing and controlling
31Chillgard LE Features
- Photoacoustic IR sensor
- Standard gases R123, R134a, R11, R12, R22
- Minimum detection level - 20ppm
- Single-point diffusion, single-point pumped or
4-point pumped models
32Chillgard LE Features
- Complies with ANSI/ASHRAE 15
- UL approval
- Water- and corrosion-resistant plastic enclosure
- Easy to operate, install and maintain
- 2-year warranty
33Chillgard LE Features
- 24 VAC/DC or 110/220 VAC power
- Easy-to-use digital display with 4-button keypad
- Provides gas reading, alarm status,
calibration and fault diagnostics - Water- and corrosion-resistant enclosure
34Chillgard LE Features
- 4-20mA and RS-232 output
- 0-10 V point identifier output
- 4 relays - 3 levels of alarm fault
- 85 dB horn, 100 dB horn option
35Chillgard LE Gases
- R400 and R500 series of refrigerants
- Blends of multiple refrigerants to obtain good
thermodynamic properties in the chiller, with
reduced corrosion and ozone depletion potential. - Includes R404a, R410a, R407c, R507
- Order with custom calibration
- Other refrigerants possible
36Chillgard LE Summary
- Low cost refrigerant sensor
- Improved PIR technology
- Multiple outputs
- Configurable to meet your needs
- Easy to install, operate and maintain
37Chillgard L Series Summary
- Effective Meets ASHRAE standards for
refrigerant monitoring - Flexible Configurable to meet application
needs - Advanced Photoacoustic infrared bench design
- Efficient Detects low levels of refrigerant gas
with low cost of ownership
38Chillgard L Series