Title: Coming Attractions Future Capabilities for VistA Imaging
1Coming Attractions Future Capabilities for
VistA Imaging
- Ruth Dayhoff and the VistA Imaging Team
2 3Patch 69 (Caché)
- Migration of DICOM Gateway from MSM to
InterSystems Caché - Supported version of MUMPS
- Same implementation as VistA HIS
- Minimal application code change
- Much better installation procedure
4Patch 66 (DICOM Query/Retrieve)
- Query/Retrieve is the DICOM Standard mechanism
used by a medical device to find and retrieve
studies from another medical device containing
the desired information - Query gives a medical device the ability to
determine a studys existence on the VistA
Imaging database - Retrieve gives a medical device the ability pull
the study from VistA Imaging back to the
requesting medical device. - Causes VistA Imaging to send the studies as DICOM
objects
5 Update Commercial PACS Interface
- Current 1997 commercial PACS interface is
outdated - Uses VA-defined non-standard messages
- Migrate to IHE-based PACS interface
- Promotes interoperability
- Improves Patient Safety
- Needed to support the requirement for VistA
Imaging to be the permanent archive for all
digital medical images
6Migrate to IHE-based PACS Interface
- Benefits of IHE-based deployment
- Well-understood, industry-standard definitions of
data elements and communications - Enables validation of commercial systems against
industry profile - Uses HL7 messaging for orders and demographics
- Uses DICOM messaging for worklist queries and
images
7Current state of VistA interfacing to commercial
PACS (1997 vintage)
8Current state of VistA interfacing to commercial
PACS (1997 vintage)
9IHE-Based VistA interfacing to commercial PACS
10IHE-Based VistA interfacing to commercial PACS
11IHE-Based VistA interfacing to commercial PACS
12Patch 49 IHE-based HL7 PACS Interface Messages
- Works with RAD5.047
- Study Instance UID generated by VistA Imaging and
passed to Commercial PACS - Improves Patient Safety
- Site-specific Accession Number
- Needed for VA enterprise-wide imaging
- Specifications are published on the Web
- www.va.gov\imaging
13Patch 55 IHE-based DICOM PACS Interface Messages
- Provides industry-standard method for copying of
images from PACS to VistA - Image Availability Notification message sent from
PACS to VistA - Indicates DICOM objects that can be retrieved
from the PACS - VistA will pull these objects to its archive
- VistA will contain an additional capability to
track the progress of missing PACS studies and
pull them, when necessary
14Patch 34 Storing all DICOM Objects in VistA
Imaging in DICOM format
- VistA Imaging is the long-term archive for the VA
(System of Record) - Any DICOM object will be able to be stored on
VistA and accessed via Q/R - Some DICOM objects stored on VistA may not be
displayable (e.g., used for processing)
15Patch 34 Enhanced Duplicate DICOM UID Checking
- Unique Identifiers (UIDs) designate Study,
Series, and Image entities in DICOM - Problems have occurred in the VA when UIDs are
not unique - VistA Imaging will check for duplicate DICOM UIDs
- Email will automatically be generated used to
notify people of duplicates - First part of a comprehensive duplicate UID
handling scheme
16Outside Radiology Reports
- Radiology Project that includes VistA Imaging
enhancements - Indicator for Outside Reports
- Administratively complete outside radiology
reports in VistA - Provide proper workload credit
17DICOM IMPORTER
- Importing DICOM images from outside institutions
is labor intensive - Must place Radiology order on VistA use DICOM
Modality Worklist - IMPORTER application will use new radiology
automated order entry capability - User time to import a study drops from 7-15
minutes to 30 seconds - Will work for both CDs and miss-associated DICOM
images
18Select Study from CD
19Verify Study Selected
20Select Image to Review
21Verify Image
22Select Radiology Procedure for Study
23Select Patient for Importation of Study
24Select Additional Studies for Patient
25Importing Study
26Studies Available for Viewing in CPRS and VistA
Imaging
27Clinical Display (P72)
- Clinical Display Demo
- VA/DOD Image Sharing
- Radiology Viewer Changes
28Patch 72
- DICOM Encapsulated PDF
- Provides a means to obtain computer generated
reports into VistA Imaging - Some newer instruments can output these directly
- 3rd party vendors can convert printer output from
legacy devices - Complements DICOM Structured Reporting
Original PDF
29DICOM ECGs (far future)
- ECGs are handled as DICOM objects
- Allows ECG equipment components to be
interchangeable (carts, interpretation software,
databases) - Discrete data permits a variety of processing
capabilities - Different kinds of presentation (different leads,
for example) - Comparisons between examinations, difference
analysis
30Recent Patch Releases
- Patch 59 TIU lt-gt Imaging Enhancements
- Targeted for release August 2007
- Link Image to New Note, Addendum, Existing Note
- Administrative Closure
- Select date of document
- Date/Time of Image lt-gt Note Association
31Upcoming Patch Releases
- 62 Imaging Release of Information (ROI)
- Print All/Selected documents and images
- Copy (Burn) Images to CD
- Create PDF from Images for export
- 93 Imaging Display
- Usability enhancements - Image groups
- Filter enhancements
- 94 Imaging Capture
- Multiple page color documents
32Future Patches
- Watermarking of Rescinded Advance directives
- Placeholder for Deleted Image
- No more scanning placeholder.
- Image Edit functions
- Images scanned/attached to wrong report
- Images scanned/attached to wrong patient.
- Image Index Edit
- Modify index fields
33 34VistARad
- Patch 76 in field test
- Integration with Voxar 3D
- Section 508 compliance
35VistARad 508 Compliance and Voxar 3D Integration
36VistARad 508 Compliance and Voxar 3D Integration
37VistARad
- End of life Patch 32
- Acquisition Date/Time
38VistARad User Site Survey
- Establish VistARad priorities
- Collect input from users on needs
- Prioritization of enhancements
- Planning for future patch releases
39VistARad User Input
- Routing tracking and management
- Auto-route related priors with On-Demand Routing
- Teleradiology improvements
- Ability to read exams from multiple sites
- Multi-site combined worklist features
- Remote image view capability
40VistARad User Input
- Hanging Protocol Enhancements
- Simplify Master Image Set definitions
- Definitions to display exams in the VistARad
Browser Window on load - Export/Import of HP definitions
- Annotation improvements
- Ultrasound measurements support
41VistARad User Input
- Open images from the series (vs. study) level
- Immediate image display when loading
- Workflow management improvements
- ReadList interactions
- Display images from a Reserved exam
- Flag problem exams interrupted session
- Enhance Integration with Dictation and 3D systems
42VistARad User Input
- Teaching file support
- Support Mammography screening on mammography
approved video sub-systems - Technology upgrades
- 64-bit platform for expanded memory requirements
- Technologist QA/Status tracking function
- Display of scanned documents
43VistARad User Input
- Mensurated Scale
- DICOM Conformance Updates
- Enhanced CT and MR (Multiframe)
- Process Group 6000 Overlay data
- Grayscale Softcopy Presentation State
- Contrast/Brightness adjustment for color images
44Thank You!