The Status of GEO600
  • Joshua Smith for the GEO 600 team

2
Recent Work (Examples)
  • Increasing Robustness Detector
  • More Digital Control (with dSPACE)
  • Implemented on Signal-recycling longitudinal and
    Michelson Auto-alignment control loops
  • allows aggressive filtering of detection noise
    limited feedback signals, notching, resonant gain
  • Increased MI gain More stable locks (less
    saturations in MI loop), less modulation of
    signals
  • New de/modulation setup from lemo to SMA,
    quality components
  • Changed laser and increased power (full input
    Pwr)
  • Radiation pressure compensation in modecleaners
  • Increasing data quality
  • Elimination of 1s glitches by lowpassing cal.
    parameters
  • Scattering on SR Bench (Again!)

3
Sensitivity
Peak 5e-22
4
Inspiral Range
Design BH-BH 42MPc, for optimal position
(factor 5/2 higher)
http//www.geo600.uni-hannover.de/georeports/
MPc
5
Noise Projections hP
6
Work Ahead, S5 Plans
  • Period of intense noise hunting
  • Overnight and weekend runs
  • Best guess around Christmas
  • With well-calibrated detector output
  • Join S5
  • When additional improvements will take too long
    or are too risky to implement

7
The End!
8
Optical Layout
9
SR FB analog vs. digital
10
New MI longitudinal loop
Old

New Much more gain _at_ low f
11
Start-of-the-second glitches
12
Bennos Email
  • We plan to join S5 as early as possible in an
    overnight/weekend mode. In this mode we will work
    on the detector during the daytime. In the
    evening we make sure that the calibration process
    is running reliably and we will provide
    callibrated h(t) data and a data quality channel.
    All analyses that make their own data quality cut
    and do not rely on instrumental vetoes might find
    these data useful. In this mode all other
    detector and environmental channels will be of
    limited reliabilty and possibly of limited
    quality.
  • We are working hard to implement a number of
    changes that have been identified as necessary
    during noise hunting work. The most urgent ones
    involve changes to the Michelson length control
    loop. As this work affects the calibration
    parameters we are not confident to provide h(t)
    until the changes in the MI loop are finished and
    we have a stable confirmed calibration again. Our
    best guess is that we will join S5 in the
    overnight/weekend mode around Christmas.
  • We will continue commissioning until we feel
    additional improvements will take too long or are
    too risky and then join S5 in a 24/7 mode.

13
Nonlinear Actuator Up-con
14
Nonlinear Actuator Beats
15
Nonlinear Noise vs. Bias 600V
16
Nonlinear Noise vs. Bias 60V
17
Nonlinear Noise vs Bias V
Further decrease in bias not optimal !