Title: Equipment by Functional Areas
1Equipment by Functional Areas
Optional Side Trip
- Chapter 5
- Equipment by Functional Areas
2 Chapter 5 Objectives
- Identify
- Functional areas or the locations where a
specific task or group of similar tasks occurs - Space requirements
- Equipment needs
- Energy and water requirements
- Facility environmental concerns
3Functional Areas
4Receiving
- As a Functional Area . . .
- The first step in the flow of food
- The first control point
- The first spot to certify that products are
- In good condition
- At appropriate temperature
- Delivered as ordered
5Receiving
- Equipment Needs
- 2-wheeled hand truck and/or 4-wheeled platform
hand truck - Utility carts
- Table/desk for paperwork
- Scales
- Thermometers
- Fly fan
6Receiving
- Things to Think About
- Activities include
- Inspection of incoming food and supply items
- Acceptance or rejection of goods
- Door thresholds
- Low enough to allow hand trucks and carts to roll
over them easily
7Receiving
- Electrical panels
- Should not be located here
- Convenience electrical outlets
- Must be located here
- Light level
- Recommend 50 foot-candles
8Storage
- Equipment Needed
- Shelving Materials
- Stainless Steel
- Chrome Plated
- Zinc Plated
- Epoxy Coated
- Polymer (plastic)
- Aluminum
9Storage
- Equipment Needed
- Shelving Materials
- Stainless Steel
- Most expensive
- Excellent for use in high-humidity areas
- Most durable finish
- Chemical resistant
- Will not rust or corrode
- Will clean easily
10Storage
- Equipment Needed
- Shelving Materials
- Chrome Plated
- Bright metallic finish
- Limited corrosion and rust protection
- More durable than zinc plating
- Should not be used in high-humidity areas, such
as walk-ins and dish rooms
11Storage
- Equipment Needed
- Shelving Materials
- Zinc Plated
- Bright metallic finish
- Limited corrosion and rust protection
- Most cost-effective plating
- Should not be used in high-humidity areas, such
as walk-ins and dish rooms - Use for dry storage, not chemicals
12Storage
- Equipment Needed
- Shelving Materials
- Epoxy Coated
- Should be placed on plated shelves
- Good for use in high-humidity areas
- Usually carries manufacturers extended warranty
against corrosion and rust
13Storage
- Equipment Needed
- Shelving Materials
- Polymer (plastic)
- Will not rust or corrode
- Excellent for use in high-humidity areas
- Will clean easily
- Available in many weight-bearing capacities
- Chemical-resistant
14Storage
- Equipment Needed
- Shelving Materials
- Aluminum
- Lightweight
- Inexpensive
- Finish will oxidize and rub off on stored
products - Not chemical-resistant
15Storage
- Equipment Needed
- Shelving Materials
- Never use the following
- Galvanized or painted galvanized shelving
- Wood
- Difficult to clean and sanitize
- Will damage easily (splinters)
- Cannot be adjusted
- Will rot where it meets the floor
- Not accepted by health inspectors
16 Storage
- Equipment Needed
- Shelving Construction
- Uprights (posts) the important thing to
remember is how the shelf is attached to the post - Set-Screw
- Nut Bolt
- Post Clips
17Storage
- Equipment Needed
- Shelves
- Wire
- Slatted (Louvered)
- Solid
18Storage
- Equipment Needed
- Shelving Options and Accessories
- Explore the Possibilities
- Caster, can racks, bin markers, shelf dividers,
pan racks, dunnage racks, and pallets - Keep in Mind
- You are buying a storage system
- Maximize your storage space
- Chemicals, detergents, and soaps must be stored
separately from food and paper goods
19Soap/Chemical and Janitor Supply Storage
- Equipment Needed
- Other Equipment Considerations
- Soap and chemical shelving
- Washer/Dryer (optional)
- Laundry counter with sink
- Mop sink
20Soap/Chemical and Janitor Supply Storage
- Soap and Chemical Shelving
- Cleanable
- 6 off floor minimum
- Chemical- roof or non-corrosive
- Solid shelves
- Mop rack needed in this room
21Soap/Chemical and Janitor Supply Storage
- Electrical
- At least one outlet in each storage room
- No electrical panels here (electrical code
violation) - Recommended light level
- Minimum 30 foot-candles
- Up to 50 foot-candles in high activity areas
22Soap/Chemical and Janitor Supply Storage
- Mechanical
- Provide heating and ventilation only
- 2 to 3 air changes per hour
23Dry Storage
- As the Second Functional Area . . .
- Food and supplies are moved from receiving to
dry, refrigerator, and freezer storage - Dry storage and chemical storage must have all
contents stored separately - Food must never be mixed in a storage area with
chemicals or cleaners
24Dry Storage
- Equipment Needs
- Shelving system
- Dunnage racks
- Can storage rack (optional)
- Utility carts
25Dry Storage
- Equipment Selection
- Shelving will impact on
- Air circulation
- Pest prevention
- Stock rotation
- Storage shelving
- Approximately 74 tall
- 21 deep shelves are ideal
- Dunnage platforms should be at least 6 off
floor
26Dry Storage
- Equipment Selection
- Spacing of shelves
- Four shelves in all
- The bottom shelf should be 6 off the floor
- Next two spaced at 26
- The top shelf at 74 above the floor
27Dry Storage
- Electrical
- No electrical panels in this area (electrical
code violation) - At least one electrical outlet
- Recommended light level - 30 foot-candles
- Light fixtures should not extend below 8 inches
of ceiling - A light switch should be located in the room
28Dry Storage
- Other Considerations
- Heating and air conditioning should be available
in this area with 3-4 air changes/hour - Do not place hot water heater in this area
- Install a sprinkler system for extra protection
- Environmental Conditions
- Area should be clean, dry, well-ventilated, and
temperature-controlled - Temperature should be between 50F - 70F
29Refrigerated Storage
- Equipment Needed
- Walk-in cooler
- Walk-in freezer
- Cooler/freezer shelving
- Cooler/freezer dunnage racks
- Mobile angle rack (optional)
30Refrigerated Storage
- Walk-in coolers and freezers are best
- Suggested height 8 6
- Shelving
- Approximately 60 high
- 4 shelves spaced at 18
- Bottom shelf 6 off floor
31Refrigerated Storage
- Aisles
- Large enough for hand trucks and carts
- 36 minimum, 42 - 48 desirable
- Amount of Refrigerated Space Required
- Allow 1 sq. ft. of shelf space for each student
meal - Divide equally between the cooler and the freezer
- Be generous with the space allotted
32Refrigerated Storage
- Other considerations
- Size of doors should be 36 minimum
- Floors
- Easy to clean
- Non-slip
- Level with outside floor
- Ceilings should be light-colored to reflect light
33Refrigerated Storage
- Electrical
- Provide
- Disconnect switches as required by Code
- Lighting from front to back of refrigeration
units - Light switch outside of unit or in a vapor-tight
box inside unit - Light level at 30 foot-candles
34Refrigerated Storage
- Mechanical
- Compressors, defroster, fans, etc. are typically
provided with the unit - Plumbing
- Provide a floor drain
- Locate condensing unit
- outside of building
35Preparation/Hot Food Production
- As a Functional Area . . .
- Hot food production
- Key functional area in the conventional
foodservice system - Selection of type of equipment is affected by
- Menu
- Labor availability and skill
- Serving schedule
36Preparation/Hot Food Production
- Equipment Needs
- Preparation
- Bakers table with portable bins
- Disposer
- Drinking fountain
- Food processor
- Hand sinks
- Heater/proofer cabinet
- Meat sink
37Preparation/Hot Food Production
- Other Equipment Needs
- Preparation
- Mixer
- Portable carts
- Pot/pan shelving units
- Preparation/work tables
- Slicer
- Vegetable sink (2-compartment)
-
38Preparation/Hot Food Production
- Other Equipment Needs
- Cooking
- Combination oven/steamer
- Convection oven
- Convection steamer
- Cooks sinks
- Cooling racks
- Exhaust hood
- Fryer (optional)
- fFyer filter (desirable)
- Range
- Trunnion kettles (batch cooking)
39Preparation/Hot Food Production
- Mixer
- Range from 5-quart tabletop to 140-quart floor
models, indicating bowl size - Agitators flat beaters, dough arms, wire whips,
pastry knife - Optional equipment vegetable slicer, bowl
splash cover, bowl extension attachment, bowl
truck, bowl scraper, chopper/grinder, dicer,
colander, stop and start controls, and
programmable controls -
40Preparation/Hot Food Production
- Vertical Cutter Mixer (VCM)
- VCM consists of conical mixing bowl with motor
mounted at bottom - Removable sleeve with cutting blades mounted on
motor shaft which projects from bottom of bowl - Sized from 10-quart countertop model to 130-quart
floor model -
41Preparation/Hot Food Production
- Tilting Braising Pan Workhorse
- A one-piece stainless steel pan with vertical
side walls, a front pouring lip, and hinged
stainless steel cover - Uses
- Brown or braise stew meats, ground beef
- Fry chicken, fish
- Sauté or steam vegetables, stir fry
- Cook soups, stews, sauces
- Back-up grills, steamers, kettles
-
42Preparation/Hot Food Production
- Steam Jacketed Kettle
- Cylindrical in shape with a rounded bottom, a
second cylinder is placed on the outside to allow
steam to circulate between the two - Available in direct steam or self-contained
electric or gas with stationary or tilt option - Uses
- For boiling, stewing simmering, braising,
holding, and reheating - Examples
- Soups, stews, sauces, gravies, pasta, rice,
puddings, pie fillings, vegetables, cereals, meat
roasts, poultry, shrimp, lobster, tea
43Preparation/Hot Food Production
- Convection Steamer
- Pressureless steamer available with
self-generating gas or electric steam coil
generators and direct steam models - Each compartment capacity is equated to the
number of 12X20X2 deep pans it will hold
44Preparation/Hot Food Production
- Convection Steamer
- Requires a water supply
- Uses
- Steam cooking, defrosting, and reheating
- Examples
- Vegetables, rice, pasta, eggs, poultry, seafood,
meats, prepared foods, frozen entrees, hot dogs,
potatoes
45Preparation/Hot Food Production
- Pressure/Pressureless Steamer
- Offers the flexibility to operate in a pressure
(5-5 psi) steam or a pressureless steam mode - Requires a water supply
- Uses
- Steam cooking, defrosting, and reheating
- Examples
- Vegetables, rice, pasta, eggs, poultry, seafood,
meats, prepared foods, frozen entrees, hot dogs,
potatoes
46Preparation/Hot Food Production
- Combination Oven Steamer
- Offers a single cooking chamber with ability to
cook in three cooking modes, which include hot
air mode (convection oven), a steam mode
(convection pressureless steamer), and a
combination of both modes - Available in gas or electric models
- Requires a water supply
-
47Preparation/Hot Food Production
- Combination Oven Steamer
- Uses
- Roast, steam, bake, poach, blanche, grill,
defrost, cook-and-hold, and reheat - Examples
- Vegetables, poultry, seafood, meats,
- Frozen entrees, muffins, breads, pizza, prepared
foods
48Preparation/Hot Food Production
- Convection Oven
- Offers a cooking chamber with a fan to circulate
hot air - Available in gas and electric models
- Uses
- Bake, roast, slow roast and hold, and reheat
- Examples
- Breads, cookies, cakes, pies, meats, poultry,
seafood, frozen entrees, pizza, potatoes, grilled
cheese sandwiches, macaroni and cheese
49Preparation/Hot Food Production
- Equipment Selection
- Base on menu, but keep as multi-purpose and
simple as possible - Specify back covers for equipment if back is to
be visible - Stainless steel is usually less expensive in the
long run - Provide soap and hand towel dispensers at each
hand sink
50Preparation/Hot Food Production
- Equipment Selection
- Pot and pan storage racks should be mobile
- In baking area
- Provide a bakers table with backsplashes and
mobile ingredient bins for ease of transport from
storage area - Area should be convenient to a water source
- Provide mobile proofing cabinet, mixer(s), and
oven(s)
51Preparation/Hot Food Production
- Equipment Selection
- Provide parking space adjacent to each work area
for mobile carts used to transport food from
storage areas - Provide a clock in this area
- Locate cooking equipment in a central location
to enhance cleaning and efficiency
52Preparation/Hot Food Production
- Electrical
- Requirements should be coordinated
- with equipment specifications
- Verify voltage, amperage, and type of connections
required - Electrical devices mounted near floor should be
weatherproof and hard piped several inches off
the floor for ease of cleaning
53Preparation/Hot Food Production
- Electrical
- Recommended light level in the kitchen area is 75
foot-candles - Light fixtures should be lensed and gasketed to
prevent moisture from damaging fixture - Emergency lighting should be provided in this
area to meet the requirements of the Life Safety
Code - Connect hood fire suppression system to building
fire alarm system
54Preparation/Hot Food Production
- Mechanical for Prep Area
- HVAC system should be part of system that serves
cooking and serving areas - Should supply a minimum cooling load of 48
BTU/square foot - Unit will provide the balance of make-up air
needed to replace the air exhausted by the
exhaust hood
55Preparation/Hot Food Production
- Mechanical for Cooking Area
- HVAC system should be part of system that serves
prep and serving areas - Minimum cooling load of 100 BTU/square foot with
room temperature of 80F - All air supplied to the cooking area will be
exhausted through the kitchen hood - Hood should be U.L. listed and designed in
accordance with National Fire Protection
Association 96 - Hood should overhang all equipment by 9
56Preparation/Hot Food Production
- Plumbing
- Provide hand wash sink in prep area
- Stainless steel with electric eye or foot pedal
operation to eliminate hand contact with faucet
handles - Supply all prep sinks with wrist blades to reduce
food contact with faucet handles
57Preparation/Hot Food Production
- Plumbing
- Provide garbage grinder in drain of prep sinks
(if approved by local plumbing codes) - Pipe all floor drains and waste outlets from
cooking equipment to a central grease interceptor - Provide a master gas shut-off valve
58Preparation/Cold Food Production
- As a Functional Area . . .
- A variety of activities take place, from washing
produce for preparation to slicing, chopping,
mixing, and plating
59Preparation/Cold Food Production
- Equipment Needs
- Cooling units
- Refrigerator
- Freezer
- Blast chiller
- Mixer
- Slicer
- Cutter/Mixer
60Preparation/Cold Food Production
- Blast Chiller
- Designed to rapidly cool food
- An essential component of HACCP system
- Product brought below 41F in 90-120 minutes or
less - Capacity needs (determined in pounds per load)
equal the number of persons the chiller can serve
for three meals per day
61Preparation/Cold Food Production
- Ice Machine
- Ice is considered a food and must be handled as a
food - Rated according to the amount of ice produced in
a 24-hour period - Consider the storage bin plus the count of ice
produced during the peak period total ice
available - Requires 20 psi water pressure
62Preparation/Holding
- Equipment Needs
- Cabinets
- Heated
- Refrigerated
- Holding Cabinet (warming or heater/proofer
cabinets) - Function is to hold prepared food hot for service
at a set temperature - Unheated cabinets are used for holding and
transporting large quantities of prepared foods
not requiring holding at a set temperature
63Preparation/Holding
- Holding Cabinet (continued)
- Mobile or stationary
- Reach-in or pass-thru
- Roll-in or roll-thru
- Aluminum or glass doors
- Pass-thru holding cabinets hold food between the
kitchen and serving area - Locate holding cabinets near prep and serving
counters for efficiency - Consider half-size doors to cut down on heat and
cold air losses when doors are opened
64Preparation/Holding
- Electrical
- Electrical devices are floor level,
weatherproofed, and installed for ease of
cleaning - Recommended light level of 50 foot-candles
- Mechanical
- HVAC should be part of system that serves cooking
and serving - Should supply a minimum of 48 BTU/sq. ft.
65Warewashing
- As a Functional Area
- The functional area of warewashing is important.
It is here that soiled dishes, glasses, flatware,
trays, pots, and pans are cleaned and sanitized.
66Warewashing/Pots and Pans
- Equipment Needs
- A garbage disposal with a pre-rinse spray is
useful at the soiled end of operation - A three-compartment sink is needed and a
four-compartment sink is desirable if space
allows - The sanitizing compartment must be large enough
to submerge the largest pot/pan used in facility - Hot water booster to maintain 180ÂşF minimum
- Chemical injector
- Drainboards provided at each end of pot and pan
sinks, as wide as the widest sink compartment
67Warewashing/Pots and Pans
- Location of Area
- Locate near dishwasher so that pots and pans can
be run through dishwasher for sanitizing - To avoid cross-contamination, do not locate
soiled area near a clean area
68Warewashing/Pots and Pans
- Electrical
- Electrical devices located at floor level should
be weatherproofed and easy to clean around - Recommended light level of 50 foot-candles
- Plumbing
- Faucets should have 3/4 supplies
- Sink compartment drains should be lever-handle
style
69Warewashing/Pots and Pans
- Mechanical
- HVAC system should be part of the system serving
cooking and serving - Based on a minimum cooling load of 48 BTU/sq. ft.
- Unit should provide balance of make-up air to
replace air exhausted by kitchen exhaust hood
70Warewashing/Dish and Tray
- Equipment Needs
- A soak sink in the scraping area for soaking
flatware before washing is useful - In larger schools a scraping trough connected to
a disposal is more efficient - Soiled dish table large enough to accommodate
trays and dishes while pre-rinsing - Pre-rinse area
- Should have an overhead spray and disposer and be
near soiled dish table to avoid unnecessary steps
71Warewashing/ Dish and Tray
- Equipment Needs
- The washer requires sanitizing water temperatures
of 180ÂşF minimum (need booster heater) - Automatic conveyor dishwasher, the clean dish
table should be at least 7 long to handle a
minimum of 4 dish racks - Provide open space of 20 under clean dish table
for parking rack dollies
72Warewashing/Dish and Tray
- Electrical
- Verify location and requirements of power to sink
heaters with plumbing consultant - Recommended light level of 50 foot-candles
- Light fixtures should be lensed and gasketed
73Warewashing/Dish and Tray
- Mechanical
- Exhaust hoods
- Install at entrance and exit to washer to vent
heat and steam - Exhaust rate of 15 to 25 air changes/hour
- System should be separate from building HVAC
system - Make-up air unit and exhaust fan should be wired
to run when the dishwasher is running
74Warewashing/Dish and Tray
- Plumbing
- Provide booster heaters capable of a 60ÂşF rise
in temperature (120-180ÂşF) for all warewashing
equipment - Provide an immersion heater in pot sink to
maintain - 180ÂşF water temperature
75Miscellaneous
- Waste Disposal
- Equipment Needs
- Garbage disposers
- Pulpers and extractor systems
- Trash compactors
76Miscellaneous
- Waste Disposal
- Equipment Needs
- Garbage disposers
- Primary function is to grind food waste and mix
with water - Waste is then piped to sewer
- Specified by horsepower ranging from 1/2 to 5
77Miscellaneous
- Waste Disposal
- Equipment Needs
- Pulpers and extractor systems
- Water and waste mixed together
- Ground into small particles
- Piped to extractor
- Water reused in grinding process and solids are
conveyed to a conventional trash container - Recommended when garbage disposers are against
municipal ordinances
78Miscellaneous
- Waste Disposal
- Equipment Needs
- Trash compactors
- Mechanical device designed to compress waste
materials so that the volume is greatly reduced
79Miscellaneous
- Waste Disposal
- Establish location for a grease disposal
container - Equip dumpster pad with water supply and drain
for clean-up - Provide an air curtain to outside entrances in
vicinity of dumpster for insect control - Do not connect garbage disposals with septic tank
systems
80Miscellaneous
- Can Washing and Drying
- The can drying rack should be 12 above the floor
to allow for air circulation - Rack should be non-ferrous to avoid rusting
- Provide area with hot and cold water supply and a
drain for clean-up - A hand sink should be nearby
81Miscellaneous
- Toilets and Lockers
- Toilet areas
- The toilet areas should have toilets, lavatories,
soap dispensers, towel dispensers, and mirrors - Employee locker area
- Lockers 72 high by approximately 15 wide with
provisions for locks or padlocks - A bench and coat rack provided here or outside
managers office
82Miscellaneous
- Toilets and Lockers
- Equipment and space requirements must comply with
the Americans with Disabilities Act - Provide convenience receptacles in toilet and
locker area
83Miscellaneous
- Office(s)
- Equipment Needed
- Desk, chairs, bookcases, locking file cabinets,
computer table or desk with printer stand and
typewriter stand - Consider
- Space and wiring for computer
- Plenty of electrical receptacles for computer and
other office equipment