Title: Thermal control GSE at KSC


1
Thermal controlGSE at KSC
2
TCS GSE scope
  • AMS at KSC will be in flight configuration
    (radiators)
  • The TCS GSE shall allow the correct detector
    operation during the ground integration.
  • The only GSE to be used at KSC will be
    electrically powered fans of two kind, to provide
    forced convection cooling.
  • Several fans will blow air towards specific AMS
    components in order to keep their temperature in
    the operative range.

3
Elements to be cooled
  • Air cooling
  • Electronic crates and XPDs
  • Main radiators (RAM and WAKE) mounted
  • Cryocoolers (with LHP integrated, hence sunk to
    the zenith radiators)
  • PDS (mounted on WAKE radiator)
  • CAB (with LHP integrated, hence sunk to the wake
    radiator)
  • All other subdetectors dont need forced
    convection cooling, free convection being
    sufficient.

4
Type A Fans
  • Quantity 12
  • Diameter gt 0.45 m
  • Flow Rate 4100 m3/h
  • Unit power (reference value) 135 W
  • Voltage 110 V
  • AC supply Frequency 60 Hz

5
  • Four fans will blow to the electronic units
    mounted on the Ram radiator, having their axis
    parallel to the radiator
  • Four fans will blow to the electronic units
    mounted on the Wake radiator , having their axis
    parallel to the radiator
  • Four fans will blow the Zenith Radiator, having
    their axis parallel to the 4 zenith radiator
    quadrants

6
Fans on zenith radiators
Ram
Wake
Main Radiator Wake
Main Radiator Ram
7
Fans on RAM radiator
Ram
Wake
Main Radiator Wake
Main Radiator Ram
8
Fans on WAKE radiator
Ram
Wake
Main Radiator Wake
Main Radiator Ram
9
(No Transcript)
10
(No Transcript)
11
Type B Fans
  • Quantity 3
  • Diameter gt0.18 m
  • Flow Rate 740 m3/h
  • Unit power (reference value) 50 W
  • Voltage 110 V
  • AC supply Frequency 60 Hz

12
Type B fans usage
  • One fan is dedicated to the PDS, and it shall
    work at the same time of the Wake radiator fans.
  • The other two fans shall blow air to the CAB on
    two of its faces (wake and starboard).

13
Type B fans location
Ram
Wake
Main Radiator Wake
Main Radiator Ram
14
Quality stamp on COTS
  • All fans will be commercial off the shelf (COTS)
    and have the European CE quality symbol on it.
  • The supplier of the fans is TBD.