Title: ESSential Solution Segmented Aspheric Multifocal
1ESSential Solution Segmented Aspheric Multifocal
2What is ESSential Solution?
- Two leading industry products merge
- ESSential multifocal
- SOLUTION bifocal
3What is ESSential Solution?
- Translating design with intermediate vision
- Up to 3.50D add in a thinner lens profile
- Decreased lens mass increases patient comfort
4What are the Fitting Goals?
- Position slightly below center
- Segment height just below the pupil
- Allow for slight rotation
5Who are the Best Candidates?
- Mid-life and mature patients who require
excellent vision at all levels
- Intermediate vision for computer users
- Reading segment for clear near vision
6Lid Position is a Key Factor
Optimal
7What are the Lens Parameters?
BC Power Add Seg positions Diameter Prism
ballast Material
7.10mm to 8.20mm (0.10mm increments) 6.00D to
10.00D (0.25D increments) 0.75D to 3.50D
(0.25D increments) 1.0mm and 1.5mm BGC 9.3mm
Medium at 90 standard (available /-
20) Boston XO - Ice Blue color
8Presbyopic Success Fitting
System
Discussion of fitting steps
- Select the base curve along with the
distance power adjustment - Add 0.50D to the spectacle Add power
- Choose segment position
- Order 9.3mm diameter
9Fitting Example
Spectacle Rx -2.00 - 0.75 x 180 Add 2.00D K
Readings 42.50 _at_ 180 / 43.25 _at_ 090
10Step 1 Determine Base Curve and Distance
Power
Spectacle Rx -2.00 - 0.75 x 180 Add 2.00D K
Readings 42.50 _at_ 180 / 43.25 _at_ 090
Base curve 7.80mm Distance power - 2.75D
11Step 2 Determine Near Power
Spectacle Rx -2.00 - 0.75 x 180 Add 2.00D K
Readings 42.50 _at_ 180 / 43.25 _at_ 090
- Determine the patients spectacle Add power and
add 0.50D
Base curve 7.80mm Distance power - 2.75D Add
2.50D
12Step 3 Choose Segment Position
Spectacle Rx -2.00 - 0.75 x 180 Add 2.00D K
Readings 42.50 _at_ 180 / 43.25 _at_ 090
- Start at 1.0mm below geometric center
- 1.5mm below geometric center is the only other
option
Base curve 7.80mm Distance power - 2.75D Add
2.50 Seg position 1.0mm BGC
13Step 4 Order Lens
Spectacle Rx -2.00 - 0.75 x 180 Add 2.00D K
Readings 42.50 _at_ 180 / 43.25 _at_ 090
- Diameter 9.3mm
- Standard medium prism at 90
Base curve 7.80mm Distance power - 2.75D Add
2.50 Seg position 1.0mm BGC Dia
9.3mm Prism standard _at_ 90
14Lens Evaluation
- Alignment along the flat corneal meridian
- Lens translation during down gaze
15Vision Evaluation
- Allow the lens to settle
- Test the patient's binocular distance and near
visual acuity - Over-refract
16Problem Solving
- Problem Solving Grid
- Lens riding high/low
- Excessive/restrictive movement
- Segment line too low/high
- Excessive rotation
- Poor near/distance vision
17Problem Solving
- Lens rides high
- Try a steeper base curve
- Lens rides low
- Try a flatter base curve
Seg too high
18Problem Solving
- Excessive movement
- Try a steeper base curve
- Restricted movement
- Try a flatter base curve
19Problem Solving
- Seg line too low
- Try a flatter base curve
- Raise segment line
- Seg line too high
- Try a steeper base curve
- Lower segment line
20Problem Solving
- Poor near vision
- Try a flatter base curve
- Raise segment line
Non-translating
- Poor distance vision
- Over-refract
- Lower segment line
- Change base curve
Translating
21Problem Solving
- Excessive nasal rotation (gt15 degrees)
- OD use prism axis 110
- OS use prism axis 70
- Excessive temporal rotation (gt15 degrees)
- OD use prism axis 70
- OS use prism axis 110
22ESSential Solution - FAQ
- Question
Why cant I special order
other parameters? - Answer
- ESSential Solution has been designed to
increase your success rate by controlling
parameter options