Title: UCSB cold box noise issue


1
UCSB cold box noise issue
Before
After
  • High noise on all 8 slots tested
  • Noise apparently caused by bias leakage current
    running through common ground on UTRIs.
  • Grounded hybrid-to-UTRI adapters to cold box
    plates.
  • Grounded slotted cold plate through power supply
    to wall ground
  • Provided shorter path to ground for bias leakage
    currents
  • Noise reduced on all slots enough for defects to
    be seen.
  • All slots have increased noise (2-4 counts) on
    chip edge channels.