EE Support TEV Abort Inputs - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

EE Support TEV Abort Inputs

Description:

(Dumps, HFUs, QBSs, UPSs) Timing: 3 ms filtering in VFCs. 60 Hz sampling of UP/DWN counters ... TEV PS/Dump Schematic. TEV Quench Protection Cell - typical. TEV ... – PowerPoint PPT presentation

Number of Views:52
Avg rating:3.0/5.0
Slides: 11
Provided by: wol75
Category:
Tags: tev | abort | dumps | inputs | quench | shunt | slew | support

less

Transcript and Presenter's Notes

Title: EE Support TEV Abort Inputs


1
EE Support TEV Abort Inputs
  • HOPS (QFA4, QFE1, QFF3, QDD1, QDE2, QDF4, SF,
    SD, SQ)
  • Abort Power Supply OFF
  • DIPOLE CORRECTORS (275 PSs located around ring)
  • Abort Power Supply OFF
  • C0 SHUNT (TC0SH)
  • Abort /- 0.5 amp or greater regulation
    error
  • 100 amps maximum
  • 11 amps/sec max. slew rate

2
EE Support TEV Abort Inputs (Cont.)
  • LOW BETA QUADS
  • 1 kamp PSs (AQ7, AQ9, AQ0, BQ7, BQ9, BQ0, CQ9,
    CQ0, DQ7, DQ9, DQ0)
  • Abort Power Supply OFF
  • High Current PSs (B0Q1, B0Q2-4, B0Q3, B0Q5,
    B0Q6, D0Q1, D0Q2-4, D0Q3, D0Q5, D0Q6)
  • Abort /- 15 amps or greater regulation
    error and/or, PS OFF
  • F17 Kicker
  • Abort Tripped/OFF

3
EE Support TEV Abort Inputs (Cont.)
  • TECAR (1, VME-based uP in A2)
  • TEV Ramp generation and PS Voltage profiles
  • QPM Communications
  • See System logic diagram for ABORT detailed
    actions
  • Abort Summary
  • QPM link failures
  • Overcurrent
  • PS Loop

4
EE Support TEV Abort Inputs (Cont.)
  • QPMs (24, Power PC uPs, one in every 1-4
    building)
  • TEV Magnet Quench Protection Monitors See
    System logic diagram for detailed abort actions 
  • Abort Summary
  • TEV Main PSs
  • QUENCHes
  • LEAD Failures
  • Quench Protection System Faults
  • (Dumps, HFUs, QBSs, UPSs)
  • Timing
  • 3 ms filtering in VFCs
  • 60 Hz sampling of UP/DWN counters
  • 3, line cycle averaging
  • 0.5 volt detection level

5
QPM/TECAR System Logic Diagram
6
TEV Ring Schematic
7
TEV PS/Dump Schematic
8
TEV Quench Protection Cell - typical
9
TEV Quench Protection Voltage Meas.
Magnet ½ Cell
10
QPM Quench Growth Rates(Cell Voltage Plots)
Write a Comment