  • DEPARTMENT OF COMMUNITY AFFAIRS
  • BUILDING CODES STANDARDS
  • MANUFACTURED BUILDINGS PROGRAM
  • MICHAEL D. ASHWORTH, MANAGER
  • 850-922-6075
  • michael.ashworth_at_dca.state.fl.us

3
FACTORY BUILT SCHOOLS(PORTABLES)
4
STATUTORY AUTHORITIES
  • S. 553.415 FSGOVERNS PORTABLE CLASSROOMS UNDER
    THE FBC (DCA)
  • RULE 9B-1.O26, 028 030 FACADDITIONAL
    PROCEDURES
  • S. 1013.20 FS--AUTHORIZES 5 YR PLAN EXEMPTION
    FROM FBC (DOE)

5
NEW CONSTRUCTION TYPE II-B (OLD IV) (SREF)
(pg.1)
  • PLANS REVIEWED BY CRA
  • MFGD BY DCA APPROVED MFGR
  • INSPECTED AT PLANT BY SCHOOL B.O. OR 3RD PARTY
    AGENCY (S.553.415(9) FS)
  • SREF INSIGNIA NOW INSTALLED AT THE FACTORY (see
    next slide)

6
(No Transcript)
7
TYPE II-B (SREF) (pg.2)
  • SITE INSPECTED BY SCHOOL ( No longer reqd by
    Rule 9B-1 Still reqd by s. 1013.20 FS)
  • INSPECTION REPORT SENT TO CRA (Deleted by Rule
    9B-1 change)
  • INSIGNIA ORDERED ONLINE (BCIS) (Deleted by Rule
    9B-1 change)
  • CRA NOTIFIES DCA OF SAT. REPORT(Deleted by Rule
    9B-1 change)

8
TYPE II-B (SREF) (pg.3)
  • SREF INSIGNIA ISSUED AFFIXED BY THIRD PARTY
    AGENCY AT PLANT (Rule 9B-1 change)
  • LEASED PORTABLES TREATED SAME AS OWNED
    (INSIGNIAS ETC)
  • INSTALLED BY LICENSED CONTRACTOR/B.O.--PERMIT

9
TYPE II-B (SREF) (pg.4)
  • SITE PLANS NOT REVIEWED BY CRA
  • DUAL PLANS REVIEWS NOT NEEDED (CRA 3RD PARTY
    AGENCY)
  • CRA DOES PRODUCT APPROVAL REVIEW
  • MFGRS SUBCONTRACTING PORTABLES CONSTRUCTION STILL
    RESPONSIBLE

10
Q ATYPE II-B (ONLY)(EXISTING PORTABLES-- NEXT)
  • ???

11
EXISTING BLDGS TYPE III-B (OLD V) V-B (OLD
VI) CONST.
12
EXISTING BLDGS--APPENDIX DTYPE OF CONSTRUCTION
2001 FBC 2004 FBC Type I Type I-A
Type II Type I-B Type III Type IV
Type IV 1-hour Protected Type II-A Type IV
Unprotected Type II-B Type V 1-hour
Protected Type III-A Type V Unprotected
Type III-B Type VI 1-hour Protected Type
V-A Type VI Unprotected Type V-B
13
TYPE III-B V-B (EXISTING) (pg.1)
  • PLANS REVIEWED BY THIRD PARTY AGENCYINITIAL OR
    RECERT.
  • SITE ANNUAL INSPECTIONS BY SCHOOL B.O.
    (S.1013.20 FS-DOE)
  • INSIGNIA ORDERED ONLINE (BCIS)
  • LEASED PORTABLES MUST BE BEAR SREF INSIGNIA

14
TYPE III-B V-B (EXISTING) (pg.2)
  • PORTABLES IN 5 YR PLAN (FBC NON-COMPLIANT) ARE
    NOT ELIGIBLE FOR DCA INSIGNIA
  • OK TO HOUSE STUDENTS W/ COMPLETED SITE ANNUAL
    INSPECTIONS (Reqd in 5 YR PLAN in S.1013.20 FS)

15
TYPE III-B V-B EXISTING (pg.3)
  • RELOCATION TO SAME WIND SPEED DESIGNNO RECERT/NO
    NEW DCA INSIG (IF REQD BY LOCAL B.O. 3rd PARTY
    AGENCY or LOCAL B.O.)
  • RELOCATION TO HIGHER WIND SPEED DESIGN
    RE-ENGINEERING OF PLANS ( POSSIBLY, BLDG) TO
    OBTAIN RECERTIFICATION.

16
TYPE III-B V-B EXISTING (pg.4)
  • RECERTIFICATIONS -- ALL SITE INSTALLATION
    (FOUNDATION, ETC.,) MUST COMPLY WITH LOCAL WIND
    SPEED DESIGN REQMNTS.
  • NO (HUD STANDARD) MOBILE HOMES CAN BE USED TO
    HOUSE STUDENTS.

17
TYPE III-B V-B EXISTING (pg.5)
  • OFF-CAMPUS SCHOOL BOARD OFFICES, STORAGE SHEDS,
    ETC., NOT HOUSING STUDENTS DO NOT HAVE TO BE
    SREF COMPLIANT.
  • ALL PORTABLE CLASSROOMS BUILT PRIOR TO 03/01/02
    SHOULD HAVE A DCA INSIGNIA (see next slide),
    UNLESS IN THE 5 YR PLAN.