Martyn Newton
  • Assistant Director of Estates and Buildings-
  • Risk and Sustainability Manager

2
Actions
  • Low energy buildings
  • Photovoltaics
  • BMS Controls
  • Combined Heat and Power
  • Absorption Cooling
  • Biomass gasification CHP

3
The University of East Anglia
4
Low Energy Buildings
Medical School
ZICER
Elizabeth Fry Building
Edith Cavell building
5
The Elizabeth Fry Building
6
The Elizabeth Fry Building 1994
Cost 6 more but has heating requirement 25 of
average building at time. Building Regulations
have been updated 1994, 2002, 2006, but
building outperforms all of these.
8
7
EFB Energy Performance
8
EFB Satisfaction levels
  • High Customer Satisfaction

9
ZICER Improve the Best
  • Improved insulation
  • Improved windows
  • Improved building sealing
  • Improved lighting
  • Improved control
  • Improved office equipment
  • Photo-voltaics

10
The ZICER Building
Mono-crystalline PV on roof 17 kW in 10
arrays
Poly- crystalline on façade 6/7 kW in 3 arrays
11
(No Transcript)
12
The ZICER Building
Low Energy Building of the Year Award 2005
awarded by the Carbon Trust.
13
Control Strategy
The space heating consumption has reduced by 57
14
UEA Energy demand
  • HEAT for space heating, domestic hot water,
    Sportspark pool heating, and temperature
    controlled research environments
  • 42,000,000 kWh per annum
  • ELECTRICITY for lighting, office equipment,
    cooking, research equipment, etc
  • 32,000,000 kWh per annum
  • COOLING due to equipment or Solar heat gain

15
Combined Heat and Power
16
UEAs Combined Heat and Power
17
Before installation
After installation
This represents a 33 saving in carbon dioxide
18
UEAs District Chilling
19
UEAs Tri-generation
20
But what fuel for the Future?
21
(No Transcript)
22
Biomass CHP
23
Why Gasification?
24
Proposed BIOMASS
  • Increasing need
  • Extra 1.4MWe ,2MWh
  • Increasing costs
  • Under 7 year payback
  • Future fuel availability
  • Local wood fuel
  • Environmental issues Environmental school,Climate
    Research Unit, Cred
  • Reduces Carbon Emissions of UEA by over 35

25
UEA Gasifier
26
Strategy for the future
  • Build low energy Buildings
  • Manage and control them well
  • Linking with Existing buildings consider district
    Combined Heat and Power
  • If there is significant cooling load consider
    absorption chilling
  • Incorporating energy efficiency measures in
    refurbishments
  • Energy awareness
  • Reduce electric heating
  • Provide renewable energy whenever economic
  • Transport
  • Waste
  • Biodiversity

27
UEA Carbon Emissions
  • 1990-2006
  • 5870-14,047 students (239 INCREASE)
  • 138,-207,000 sq.m (49 INCREASE)
  • 19,420-21,652 T of CO2(10 INCREASE)
  • 1990-2006
  • 3308-1541 kg/student (53 reduction)
  • 140-104 Kg/CO2/sq.m (25reduction)
  • 2009 Assuming Biomass
  • 24.5 reduction in CO2 over 1990 levels despite
    increases in students and building area