Title: LB2210
1LB2210 - Test Mode Accessing
To access the Test Mode Menu, hold Steam and Long
Coffee buttons and turn the machine on
The software version appears while keep
pressing. Release them to enter. To quit just
hold the Long Coffee button pressed for two
seconds in Test Mode L6. The US latest version
is 1.10.03
2LB2210 - Test Mode The display
Six Levels L1 Brewing Unit and solenoid L2
Hydraulic Circuit L3 Heating Elements L4
Not used L5 Display contrast L6 Display
brightness
Sensors 1 Brewing Unit working position 2
Brewing Unit rest position 3 Brewing Unit
presence 4 Dreg drawer presence 5 Capsule
presence 6 Capsule cage closed 7 Water tank
level 8 Flowmeter pulses
Keyboard
Six Values L1 Brewing Unit torque L2 Water
pulses L3 Temperature L4 Not used L5
Display contrast L6 Display brightness
1
3
5
2
4
3LB2210 - Test Mode Level 1
Motor torque maximum accaptable value is 25
Errors 81 to 91
Errors 11 15
Press to drive the Brewing Unit up to the working
position (needs the dreg drawer in) Sensor 1 is
on when reached
Press to activate the pod releaser solenoid
Press to energize the cup heater
Press to drive the Brewing Unit down to the rest
position (needs the dreg drawer in) Sensor 2 is
on when reached
Press to go to the Test Mode L2
4LB2210 - Test Mode Level 2
In Test Mode the average value of the flow meter
while dispensing water from the coffee outlet is
10 to 14
Errors 21 27
Press to activate the steam electrovalve Press
also Language to see water coming out from the
steamer
Press to activate the hot water
electrovalve Press also Language to see water
coming out from the steamer
Press to energize the pump
Press to the Test Mode L3
5LB2210 - Test Mode Level 3
Do not let the temp rises for too long or the
thermostats may switch off Temp is in C
Errors 51 to 54
Press to activate the main boiler heating
element Press also Long Coffee to display the
temp
Press to display the boiler temperature
Press to the Test Mode L4
Press to activate the steam heating
element Press also Long Coffee to display the
temp
6LB2210 - Error messages
Locking The message must to be reset in Service
Menu 6.3
Not Locking The message may be reset by turning
the machine off and on
7LB2210 - Error messages Locking
31. 51. 52. 53. 54. 61-68. 85.
Memory Clock Temp sensor short circuit Temp
sensor not connected or broken Boiler heating
system out of control Temperature not
rising Eprom error Brewing Unit timeout
Replace the CPU card Test Mode L3 Test Mode
L3 Test Mode L3 Test Mode L3 Replace the CPU
card Test Mode L1
8LB2210 - Error messages Unlocking
11. 15. 12. 13. 21. 27. 81-91.
Pod Releasing error after the fifth try Pod
Releasing error after the first try
(warning) Zero Crossing Coin mechanism
anomaly Hydraulic Circuit anomaly Coffee
Erogation aborted (warning) Brewing Unit sensors
or torque anomaly
Test Mode L1 Check the power supply Test
Mode L2 Test Mode L1