Title: TEST GIF SPS OCTOBER 01
1TEST GIFSPSOCTOBER 01
Tested 2 RPCs RB (1342) double-oil
65X272 cm2 RS standard
50X50 cm2
? flux varied by means of absorbers abs10
5 Hz/cm2 abs5
10 Hz/cm2 abs1 30 Hz/cm2
Detectors in front of our chambers
?-beam from SPS 10000/burst max
2EXPERIMENTAL SET-UP
7.2 C4H10 41.3 C2H2F4 50.5 Ar 1 SF6 RB
70cc/min RS 30cc/min
952 mblt P lt964 mb 20.5Clt T lt22C P0953 mb
T0294K21C VeffVa P0/PT/T0
3THE BIG RPC
x
94 vertical strips (x-strips) 16 read-out (2.81
cm wide) 22 horizontal strips (y-strips) 8
read-out (2.81 cm wide)
4 1 56 23
y
3 1 2
Efficiency measurements - different ? fluxes -
different positions
4Efficiency with GIF OFF-1
Y
X
5Efficiency with GIF ON-1
X
Y
6Efficiency with GIF ON-2
Y
X
30 Hz/cm2
10 Hz/cm2
5 Hz/cm2
7TEST GIFCOSMIC RAYS NOVEMBER-DECEMBER 01
RB (1342) double-oil RS
(1409,June 01) double-oil
? max 100-130 Hz/cm2 7.2 C4H10 41.3
C2H2F4 50.5 Ar 1
SF6 RB 70cc/min RS 30cc/min
957mbltPlt982mb 14.5CltTlt18C P0965 mb
T0289K16C VeffVa P0/PT/T0
8THE CHAMBERS
RS
RB
16 x-strips16 x-strips 14 y-strips
16 x-strips
H.V.8200 V
H.V.8300 V
Efficiency Current Counting rates
3 1 2
9Current and rates-GIF OFF
10Current and rates-GIF ON
Veff-Va
11RB Efficiency-GIF OFF
?
?
Y
X
H.V.
H.V.
12Efficiency-GIF ON
Veff-Va
13Efficiency vs Rates
With GIF OFF - uniform efficiency - 10 Hz/cm2
pos.2 - 3 Hz/cm2 pos.1 - 1 Hz/cm2
pos. 3
With GIF ON - efficiency decreasing with rate -
efficiency decrease dependent on position
14The counting method
A Rate measured at a fixed V0 and abs1
B Expected rate at a fixed V0
and abs1 (rateabs10-rateGIFOFF)86001
0(rateGIFOFF)V0
EFFICIENCY for each strip A/B
15Efficiency by counting method-1
15 Hz/cm2
115 Hz/cm2
16Efficiency by counting method-2
15 Hz/cm2
115 Hz/cm2
17Efficiency by counting method-3
?
X
Abs10 15 Hz/cm2
Y
Abs1 115 Hz/cm2
H.V.8300
Strip number
Strip number
18Laboratory test in Turin-1
19Laboratory test in Turin-2
efficiency by tracking
SY19
3
2
1
4
SY4
SX1
SX61
SX76
SX45
- Cosmic rays - Cosmic rays ? by 137Cs
20Efficiency by tracking-Pos.2
Y
Y
X
X
21Efficiency source on and off-1
( 70 Hz/cm2 measured)
22Efficiency source on and off-2
23Crowns
24Conclusion
- the efficiency is not uniform - the
efficiency decreases with rate (dry mixture?)
Outlook
- test in Turin of this RPC with humid mixture -
test at the GIF from April of a new real-size RPC