Title: Chapter 11: Dimensional Measurement


1
Chapter 11 Dimensional Measurement
  • Overview
  • Classification of Measuring Devices
  • Linear measurement and Gage blocks
  • The use of micrometer and vernier caliper
  • Optical method

2
Measuring Devices
  • Low - Resolution devices (to 0.25mm)
  • used directly or with of ,
    , surface
  • Thickness gages
  • Medium Resolution Devices (to 2.5 10-3 mm)
  • used directly or with assistance of
    accessories telescoping gages, expandable ball
    gages
  • instruments
  • Specific-purpose gages or Measuring microscopes
  • High- Resolution Devices ( to 2.5 10-5mm)
  • used directly or with assistance of some
    mechanical comparators, electronic
    comparators, Pneumatic comparators, optical flats
    monochromatic light sources
  • Super-Resolution devices various forms of
    used with special light sources

3
Linear Measurement Gage Blocks
  • Accurate measurement of length with a
    standard gage blocks
  • Gage block sets are industrys dimensional
    Classes of gage blocks for the SI system
  • Accuracy Grade Accuracy (mm)
  • 0.5 0.00003
  • 1 0.00005
  • 2 0.00010
  • - 0.0005
  • 3 0.00015
  • - 0.0005
  • Usage calibrate, setting special purpose gages,
    used with gaging devices
  • Temperature problems ?L LCa?T

4
Example
  • A steel ruler 30.48 cm long is used to measure a
    length of 20.32 cm. The ruler was manufactured in
    a controlled temperature environment of 25oC. At
    this reference temperature, the ruler has
    negligible bias error. Determine the design-stage
    the measurement error caused by thermal expansion
    in a reading of 20.32 cm. If the measurement is
    taken in a 37.8oC environment but not corrected
    for thermal expansion. Given the coefficient of
    thermal expansion of the steel is
    9.910-6in./in.oF
  • (note oF 1.80C 32)

Solution ?L LCa?T 0.046mm.
5
Micrometer and Vernier Caliper
Micrometer
Vernier
6
How to Use Micrometer and Vernier
7
Optical Method
  • Applications
  • measurement of small dimensions using
    wavelength of light
  • Measurement of by use of alignment telescopes
    with accessories and project systems
  • Interferometer use of light
  • Wavelengths of light of the various primary
    colors
  • Wavelengths from specific sources