Micromegas TPC Beam Test Result - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

Micromegas TPC Beam Test Result

Description:

Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, ... ALEPH TPC electronics. 24 amplifiers, 16 channels each. 500ns shaping time, charge sensitive ... – PowerPoint PPT presentation

Number of Views:56
Avg rating:3.0/5.0
Slides: 15
Provided by: kuro7
Category:
Tags: tpc | aleph | beam | micromegas | result | test

less

Transcript and Presenter's Notes

Title: Micromegas TPC Beam Test Result


1
Micromegas TPC Beam Test Result
  • H.Kuroiwa (Hiroshima Univ.)
  • Collaboration with
  • Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK,
    Tsukuba U, TUAT, Kogakuin U, Kinki U, Saga U

Motivation Micromegas TPC Setup Preliminary
Results Summary
The 8th ACFA Workshop on Physics and Detector at
the Linear Collider Jul. 12, 2005, EXCO, Daegu,
Korea
2
Motivation
  • Comparison of several sensors using same Field
    Cage, Electronics, analysis
  • MWPC Beam test in Jun, 2004
  • GEM Beam test in Apr, 2005
  • Micromegas

Previous talk
Beam test in Jun. 22Jul. 1, 2005 We try to
understand Micromegas TPC performance
3
Micromegas
50µm
  • Micromesh supported by 50-100µm - high insulating
    pillars
  • Multiplication takes place between the anode and
    the mesh
  • One stage
  • Direct detection of avalanche electrons
  • Small EB effect
  • Fast signals
  • Self-suppression of positive ion feedback
  • the ions return to the grid
  • Better spatial resolution
  • No wire angular effect

4
TPC
  • Length of FC 26 cm
  • Pad
  • 26 mm, 0.3mm gap
  • 32 pads12 pad rows
  • ? 384 readout channels
  • Non-staggered
  • Pad plane 1010cm
  • Readout
  • ALEPH TPC electronics
  • 24 amplifiers, 16 channels each
  • 500ns shaping time, charge sensitive
  • sampled every 80 ns
  • digitized by 6 TPDs

5
Mesh Signals
  • There is a 55Fe source attached on the back of
    the cathode plane to monitor Micromegas stability
    by looking at mesh signals
  • (Readout by a multi channel analyzer MCA 8000
    from Amptek)

Ar 5isobutane
6
Experimental Setup
  • KEK-PS p2 beam line
  • 4GeV p-
  • Super conducting magnet (JACEE)
  • B 0, 0.5 and 1T
  • Gas
  • Ar isobutane (955) vd 4.18cm/µsec at
    220V/cm

7
Preliminary Results
  • Charge Distribution
  • Pad Response
  • X Resolution
  • Z Resolution
  • Analysis
  • Double fit (developed at DESY)

8
Charge Distribution
charge distribution at Row6 as a function of Z
  • Charge distribution (B 1T)
  • For 12 rows

Edge effect
Edge effect
We saw no significant attenuation
9
Pad Response Function
  • is evaluated by a normalized charge (NQi Qi/?Q)
    on pad i, as a function of (Xpad - Xtrack)

Charge width for different drift regions (B 0T)
anode
Z ?
cathode
Distribution becomes wider at longer drift
distance
10
Width of PRF as a function of Z
B 0T
Preliminary results
B 0.5T
B 1T
Measured CD in good agreement with Mag. Simulation
11
X Resolution as a function of Z
Row6 Row7 Cd Cd(PRF)
Cd fixed for each B
Preliminary results
12
X Resolution (How to Fit?)
s0 resolution w/o diffusionCd diffusion
constant Neff effective number of electrons
Diffusion
Other
1- fix Cd from PRF 2- fit sx f(z) with s0 and
Neff free 3- Plot Magboltz curve with s0
obtained from the fit (2)Cd is known
Neff from (2)
13
Z Resolution as a function of Z
B 0T
Preliminary results
B 0.5T
  • sz ? 500µm at 0.5T

B 1T
Unlike sX, sZ has no significant B-dependence
14
Summary
  • To measure Micromegas TPC performance
  • We did the beam test at KEK-PS p2 beam line using
    4GeV neg. pions in magnetic field
  • Micromegas in TPC worked stably
  • Measured diffusion constants are consistent
    with Mag. simulation
  • sx ? 200µm , sz ? 800µm at 1T
  • But these results are still very preliminary
Write a Comment
User Comments (0)
About PowerShow.com