Title: Micromegas TPC Beam Test Result
1Micromegas TPC Beam Test Result
- H.Kuroiwa (Hiroshima Univ.)
- Collaboration with
- Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK,
Tsukuba U, TUAT, Kogakuin U, Kinki U, Saga U
Motivation Micromegas TPC Setup Preliminary
Results Summary
The 8th ACFA Workshop on Physics and Detector at
the Linear Collider Jul. 12, 2005, EXCO, Daegu,
Korea
2Motivation
- Comparison of several sensors using same Field
Cage, Electronics, analysis - MWPC Beam test in Jun, 2004
- GEM Beam test in Apr, 2005
- Micromegas
Previous talk
Beam test in Jun. 22Jul. 1, 2005 We try to
understand Micromegas TPC performance
3Micromegas
50µm
- Micromesh supported by 50-100µm - high insulating
pillars - Multiplication takes place between the anode and
the mesh - One stage
- Direct detection of avalanche electrons
- Small EB effect
- Fast signals
- Self-suppression of positive ion feedback
- the ions return to the grid
- Better spatial resolution
- No wire angular effect
4TPC
- Length of FC 26 cm
- Pad
- 26 mm, 0.3mm gap
- 32 pads12 pad rows
- ? 384 readout channels
- Non-staggered
- Pad plane 1010cm
- Readout
- ALEPH TPC electronics
- 24 amplifiers, 16 channels each
- 500ns shaping time, charge sensitive
- sampled every 80 ns
- digitized by 6 TPDs
5Mesh Signals
- There is a 55Fe source attached on the back of
the cathode plane to monitor Micromegas stability
by looking at mesh signals - (Readout by a multi channel analyzer MCA 8000
from Amptek)
Ar 5isobutane
6Experimental Setup
- KEK-PS p2 beam line
- 4GeV p-
- Super conducting magnet (JACEE)
- B 0, 0.5 and 1T
- Gas
- Ar isobutane (955) vd 4.18cm/µsec at
220V/cm
7Preliminary Results
- Charge Distribution
- Pad Response
- X Resolution
- Z Resolution
- Analysis
- Double fit (developed at DESY)
8Charge Distribution
charge distribution at Row6 as a function of Z
- Charge distribution (B 1T)
- For 12 rows
Edge effect
Edge effect
We saw no significant attenuation
9Pad Response Function
- is evaluated by a normalized charge (NQi Qi/?Q)
on pad i, as a function of (Xpad - Xtrack)
Charge width for different drift regions (B 0T)
anode
Z ?
cathode
Distribution becomes wider at longer drift
distance
10Width of PRF as a function of Z
B 0T
Preliminary results
B 0.5T
B 1T
Measured CD in good agreement with Mag. Simulation
11X Resolution as a function of Z
Row6 Row7 Cd Cd(PRF)
Cd fixed for each B
Preliminary results
12X Resolution (How to Fit?)
s0 resolution w/o diffusionCd diffusion
constant Neff effective number of electrons
Diffusion
Other
1- fix Cd from PRF 2- fit sx f(z) with s0 and
Neff free 3- Plot Magboltz curve with s0
obtained from the fit (2)Cd is known
Neff from (2)
13Z Resolution as a function of Z
B 0T
Preliminary results
B 0.5T
B 1T
Unlike sX, sZ has no significant B-dependence
14Summary
- To measure Micromegas TPC performance
- We did the beam test at KEK-PS p2 beam line using
4GeV neg. pions in magnetic field - Micromegas in TPC worked stably
- Measured diffusion constants are consistent
with Mag. simulation - sx ? 200µm , sz ? 800µm at 1T
- But these results are still very preliminary