1
Quality Test of L1 sensors
  • HPK 10 sensors
  • Tested all, 6 sent to Fermilab
  • Test structures, HPK 133 L00 CDF
  • ELMA 9 sensors
  • Tested 6 of 9

2
HPK
  • V depletion 120V consistent
  • I leakage at V depletion 50nA (except 07)
  • Breakdown seen once s/n20 at 750V
  • Strip leakage 0.04nA
  • Poly resistor value ??
  • Capacitance 70pF
  • I dielectric LCR noise

Bad Channels
3
Bad Channels
  • HPK01 none
  • HPK03 bad strip 42
  • HPK04 bad strip 346
  • HPK06 PH 13, 47, 267
  • HPK07 bad strips 27, 320
  • HPK09 none
  • HPK11 leaky 169
  • HPK12 none
  • HPK13 none Rpoly strange shape
  • HPK20 none HPK claims two low Cac

Fermilab
4
Polysilicon Resistor
  • Using 237 bias/no bias

5
Interstrip Resistor
  • Using 237 Bias/NO Bias

6
Polysilicon Resistor
  • Using 487 Bias/NO Bias

7
ELMA
  • V depletion 26V
  • I leakage at V depletion 50nA
  • Breakdown ALL at 250-350V
  • Strip leakage 0.15nA
  • Poly resistor value vary, better than HPK
  • Capacitance 80pF
  • I dielectric

8
Bad Strips
  • L1-001 1, 43, 140, 256, 276
  • L1-002 95-109, 362, 383
  • L1-003 275,384 Rpoly 4MOhm
  • L1-004 32, 168, 263, 356, 373
  • L1-005 180, 368
  • L1-006 107, Rpoly 1.3 Mohm

9
Conclusion
  • HPK
  • Polysilicon resistors are out of specs
  • ELMA
  • Low breakdown voltage