Title: NFPA 1981 2002 Edition
1Created By Asst. Chief Dean Nelson and Lt. Mike
Mason
NFPA 1981 (2002 Edition) COMPLIANT
2Aspects Of RIT Operations
- Make Sure Your RIT Air Pack Is Ready
- Carrying It To The Distressed FF Location
- Establishing Emergency Air To The FF
- Securing The RIT Air Pack To The FF
3RIT Airpacks Should Be Designed To Provide
Multiple Options In Providing Air To Distressed
FFs
Emergency Air Supply!!!
- UAC/Universal Air Connection/High Pressure Line
- Regulator Attachment/Low Pressure
- Full Face Piece Application
MAYDAY!!MAYDAY!!!
4UAC/Universal Air Connection
- All SCBAs After 2002
- Allows For Any RIT Pack To Trans-Fill Any SCBA
- Distressed FF Is Never Exposed to IDLH
Environments - Problems are Incompatibility
5REGULATOR ASSEMBLIES LOW-PRESSURE CONNECTIONS
- Removing Distressed FFs Regulator/Replacing It
With Regulator From RIT Pack - Provides More Flexibility In Applications If The
UAC Is Unavailable - Removing and Inserting Process Is Familiar To FFs
6ADDITIONAL OPTION Low Pressure Connections
- EBSS Can Be Attached To Low Pressure Line From
The RIT Pack - Can Be Used When A Regulator Change Is Not
Preferred In ILDH Environments
7FULL FACE PIECE CHANGEOVER
- Involves Performing And Replacing Face Piece Of
Distressed FF - FF Found With Missing Or Damaged Face Piece
- Distressed FF Found With Incompatible SCBA
- No UAC Available
8RIT AIR PACK CONFIGURATIONS
9Design Features
- Should be designed around simplicity and easily
manipulated - Should be lightweight
- A high shoulder carrying strap
- Pockets
- Easy access to Cylinder, Valve, UAC line,
Regulator, Face piece, EBSS - Face piece accessible but NOT attached to
regulator!!!
10IMPORTANT FEATURES
- 30 Minute Bottle Preferred/Light Weight
- Increase Ease Of Movement And Speed Of Search
- Cylinders Should Only Be Turned On When The
Distressed FF Is Located To Avoid Accidental
Activation Of Air Supply
11MOVING THE DISTRESSED FF WITH RIT AIR PACK
- Requires Multiple Rescuers
- Attached To Allow Hands Free Movement To Rescuers
- 2 Large Carabineers Attachment
- Securing It To Existing Harness Points On
Distressed FF - Carabineers Should Be Placed On RIT Air Pack To
Allow For Best Possible Air Hose And Regulator
Extension To Distressed FF
12MOVING THE DISTRESSED FF WITH RIT AIR PACK
- Carabineers Should Be Attached To The Distressed
FFs Harness To Allow Rescuers The Best Possible
Movement For Removal - Attachment To Distressed FFs Waist
Belt/Preferred Harness Conversion - RIT Air Pack Usually Positioned Between Legs Of
Distressed FF
13RICOFIRERESCUE INC.
www.ricofirerescue.com
14REFERENCE
- National Institute For Occupational Safety And
Health, NIOSH, Fatality Assessment And Control
Evaluation (FACE) 96-16, Atlanta, GA - National Fire Protection Association, NFPA
1981(2002 Edition) Standard On Self-Open Circuit
Self-Contained Breathing Apparatus, NFPA, Quincy,
MA - R.I.C.O. Rapid Intervention Company Operations
- SCOTT Health And Safety, Operation And
Maintenance Instructions