Some Lessons Learned from MCNP Usage - PowerPoint PPT Presentation

1 / 23
About This Presentation
Title:

Some Lessons Learned from MCNP Usage

Description:

Unexpected density log peaks with spatial position ... in the Presence of Mud-filtrate Invasion and Salt Mixing', SPWLA 46th Annual ... – PowerPoint PPT presentation

Number of Views:285
Avg rating:3.0/5.0
Slides: 24
Provided by: neN6
Category:

less

Transcript and Presenter's Notes

Title: Some Lessons Learned from MCNP Usage


1
Some Lessons Learned from MCNP Usage
  • Robin P. Gardner, Libai Xu, Walid A. Metwally,
    and Dan Speaker
  • Center for Engineering Applications of
    Radioisotopes
  • North Carolina State University
  • September 6th 2006

2
Outline
  • Unexpected density log peaks with spatial
    position
  • Unexpected correlated sampling effects with
    density logs
  • Spectroscopy binning effects
  • Spectroscopy Gaussian spreading

3
Unexpected Density Log Peaks
4
CTZ
Reference M. B. Holstad, G. A. Johansen,
Scattered Gamma Radiation Utilized for Level
Measurement in Gravitational Separators, IEEE
Sensors Journal, Vol. 5, No. 2, 2005
5
Alberto Mendoza et. al. (2005), Monte Carlo
Modeling of Nuclear Measurement in Vertical and
Horizontal Wells in the Presence of Mud-filtrate
Invasion and Salt Mixing, SPWLA 46th Annual
Logging Symposium, June 26-29
6
(No Transcript)
7
(No Transcript)
8
Unexpected correlated sampling effects
9
Same initial seed for different position, but
the seed is different from the previous case
10
different seeds for different positions
11
Spectroscopy Binning Effects
12
90 Channels Even Between 0 and 900 keV
13
900 Channels Even Between 0 and 900 keV
14
10 keV Increments Between 0 and 500 keV 2 keV
Increments Between 500 and 600 keV and 4 keV
Increments Between 600 and 700 keV
15
10 keV Increments Between 0 and 500 keV 2 keV
Increments Between 500 and 600 keV and 4 keV
Increments Between 600 and 700 keV
16
10 keV Increments Between 0 and 500 keV 4 keV
Increments Between 500 and 700 keV
17
10 keV Increments Between 0 and 500 keV 20 keV
Increments Between 500 and 620 keV and 5 keV
Increments Between 620 and 720 keV
18
Spectroscopy Gaussian Spreading

W. A. Metwally, R. P. Gardner, and Avneet Sood,
Gaussian Broadening of MCNP Pulse Height
Spectra, Trans. of ANS, vol. 91, pp. 789-790,
2004
Heath, R.L., 1964, Scintillation
Spectrometry Gamma-Ray Spectrum Catalogue,''
IDO-16880-1. AEC Research and Development Report,
Physics, TID-4500.
19
  • How MCNP simulates Gaussian broadening?
  • Particle energy is changed before it is tallied
    by randomly sampling an energy to be deposited
    from a Gaussian distribution centered at the
    original particle energy.
  • Our proposed idea.
  • Broadening process is performed at the end of
    simulation.

20
  • Simulation Testes

3 3NaI
Cs137
  • MCNP broadening, 1 million histories.
  • MCNP broadening, 10 million histories.
  • MCNP broadening, 100 million histories.
  • Our broadening, 1 million histories.

a0 b0.05086 c0.30486
21
(No Transcript)
22
(No Transcript)
23
  • Thank You
Write a Comment
User Comments (0)