Title: TxDOT CERTIFICATION PROGRAM WITH COMMENTS ON PORTABLES
1TxDOT CERTIFICATION PROGRAM WITH COMMENTS ON
PORTABLES
- Emmanuel Fernando
- Texas Transportation Institute
- Texas AM University
- 2003 Road Profiler Users Group Conference
- Austin, Texas
2FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
3FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
4FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
5FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
6FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
7FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
8FROM PROFILOGRAPH TO INERTIAL PROFILER-BASED
SPECIFICATION
9SPECIFICATION REQUIREMENTS
- For QA under Surface Test Type B, Contractor
provides - Inertial profiler certified according to Test
Method Tex-1001-S - Certified inertial profiler operator
10TxDOT CERTIFICATION PROGRAM
- Administered by TTI
- Equipment certification
- Profiler operator certification
- Certifications conducted monthly
11Certification of Inertial Profilers
12REQUIREMENTS FOR INERTIAL PROFILER CERTIFICATION
- Operating parameters
- Certification tests
13OPERATING PARAMETERS
- Reporting interval ? 6 inches
- Cutoff wavelength of 200 feet
- Wheelpath sensor spacing of 69 in.
- Other operational features
14OPERATING PARAMETERS
- Other operational features
- Automatic triggering of data collection
15OPERATING PARAMETERS
- Other operational features
- Provide data in electronic files
- Calculate and report IRI
- Provide for verification of calibration
16INERTIAL PROFILER CERTIFICATION TESTS
- 0.1-mile test sections
- Smooth
- Medium-smooth
17INERTIAL PROFILER CERTIFICATION TESTS
- Test Data
- Repeat profile measurements
- Data files written in required format
- Files named following convention established
18INERTIAL PROFILER CERTIFICATION TESTS
- Equipment Repeatability
- Based on 10 repeat runs
- Measured using average standard deviation
- Evaluated for each wheelpath surveyed
19INERTIAL PROFILER CERTIFICATION TESTS
20INERTIAL PROFILER CERTIFICATION TESTS
- Equipment Accuracy
- Evaluated against benchmark profiles
- Same profiler filter applied to benchmark
profiles - Average profiles determined
- Point-to-point differences in average profiles
obtained
21INERTIAL PROFILER CERTIFICATION TESTS
- Equipment Accuracy
- Test Criteria Based on Profile
- Average difference ?1 within ?20 mils
- Average absolute difference ?2 ? 60 mils
- Profile accuracy evaluated for each wheel path
surveyed
22INERTIAL PROFILER CERTIFICATION TESTS
- Equipment Accuracy
- Average IRIs from tests compared against
benchmark IRIs - Absolute difference between IRIs must be ? 12
inches/mile - Accuracy of IRIs checked for each wheel path
tested
23INERTIAL PROFILER CERTIFICATION TESTS
- Test Results
- Summary report provided
- Profiler must comply with all requirements
- Decal placed on certified profiler
24SUMMARY STATISTICS ON PASSING INERTIAL PROFILERS
25PORTABLE PROFILERS
26PORTABLE PROFILERS
27CURRENT CERTIFICATION PROCEDURE FOR PORTABLES
- System detached and re-attached from vehicle
prior to each run - 10 runs made
- Profile data evaluated against criteria
- Portable certified for use on a specific vehicle
- Further evaluations needed to verify portability
28SUMMARY
29SUMMARY
- Certification is needed to implement new ride
specification - Certification program has provided a standard for
vendors - Further evaluations needed to verify portability