Title: Polyimide joint under tension in 50% HF


1
Polyimide joint under tension in 50 HF
  • Goal to observe effect of HF solution on PI-E
    joint under tension
  • Things to look for
  • Destruction of polyimide tubing
  • Stretching/deforming of joint
  • Wire damaged or breaks or pulls out

2
  • HF tension setup
  • 100 grams tension
  • (not shown polyethylene cover on HF)

camera
tension plate
Wirejoint in pool of 50 HF
Clip, pulley, weights
Polyethylene block
3
76 hours
104 hours
120 hours
126 hours
144 hours
4
  • Closeup of joint

5
  • Conclusions
  • HF attacks glue from ends, also forms bubbles
  • Wire slips out through softened glue, knot gets
    tighter
  • Possibly some stretching/shrinking
Write a Comment
User Comments (0)