MONALISA - PowerPoint PPT Presentation

About This Presentation
Title:

MONALISA

Description:

... Reichold , Paul Coe, Matthew Warden, Geoff Rayner ... M. Warden. 3 ... MONALISA - M. Warden. 7. The importance of absolute distance measurement. Take ... – PowerPoint PPT presentation

Number of Views:42
Avg rating:3.0/5.0
Slides: 14
Provided by: hepM
Category:
Tags: monalisa | warden

less

Transcript and Presenter's Notes

Title: MONALISA


1
MONALISA
WP 3
Monitoring Alignment and Stabilisation with high
Accuracy (Previously known as StaFF)
  • David Urner, Armin Reichold , Paul Coe, Matthew
    Warden, Geoff Rayner

2
Contents
  • Motivation
  • Overview of system
  • The distance meter
  • Design
  • Construction
  • Data analysis
  • Future developments

3
Motivation
  • A critical requirement for achieving and
    maintaining luminosity in ILC is
  • Stability of Beam Delivery System
  • This is true for BDS as a whole
  • And particularly so for the final focussing
    quadrupoles
  • Achieving stability requires accurate monitoring
    of magnet positions

4
Motivation
5
The Challenge
  • Develop an optical system to accurately determine
    relative position and orientation in 6D
  • Direct line of sight may not be available
  • In general, such a system needs
  • Distance meters
  • Straightness monitors

6
The Distance Meter
  • Components
  • Reference interferometer
  • Measurement interferometers
  • Two modes
  • Absolute distance measurement, using frequency
    scanning interferometry
  • Small displacement measurement, using fixed
    frequency interferometry

7
The importance of absolute distance measurement
  • Take two fixed points
  • Measure distances to a third point
  • Triangulate this point
  • Calculate axes for displacement measurements

8
Compact Measurement Interferometer
measurement distance
  • Simple, compact design
  • Gold-coated beam-splitter cube acts as one
    interferometer arm
  • Will replace far mirror with corner cube
  • Allows for easy alignment
  • Can simultaneously measure distances to many
    points

launch fibre
receiving fibres
9
Reference Interferometer
Parallel
s
  • Both interferometers share the same phase step
    from piezo mounted mirror
  • Taking two measurements gives a measure of
    accuracy
  • Can keep one interferometer as a benchmark, and
    test alternatives with the other

10
From design to reality
  • Have constructed both reference and measurement
    interferometers
  • Testing them now

11
Preliminary Data Analysis
Measurement Interferometer
  • Start with raw photodiode voltages
  • Extract reference phase
  • Fit sinusoids to measurement interferometer
    voltages

Reference Interferometer
12
Future Development
  • Move ahead with distance meter development
  • Hardware design
  • Analysis methods
  • Change to evacuated interferometers

13
Thank you for listening
time for lunch?
Write a Comment
User Comments (0)
About PowerShow.com