BETA92 User Group Bern, October 2002 BETA 92 V3R5 - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

BETA92 User Group Bern, October 2002 BETA 92 V3R5

Description:

Limit job start and end time in the range of job submit ... deactivate after match. processing order is from low to high numbers. Scanning. Example input text ... – PowerPoint PPT presentation

Number of Views:147
Avg rating:3.0/5.0
Slides: 21
Provided by: osd53
Category:

less

Transcript and Presenter's Notes

Title: BETA92 User Group Bern, October 2002 BETA 92 V3R5


1
BETA92 User Group Bern, October 2002BETA 92
V3R5
  • Stefan Lucke
  • Projektleiter BETA92
  • Stefan.Lucke_at_betasystems.com

2
Overview
  • BETA92 V3R5 - PTFs
  • Dependant scan processing
  • Automatic reload
  • Single STC BETA92EDF
  • BETA92 WIF

3
BETA92 PTFs
  • Problem (function reader)
  • V3R5, V3R4
  • Correct duplicate dataset id handling when a job
    switch occurs.
  • V3R4
  • correct OMS HICC card and error text handling
    during JBR merge.
  • PTFs
  • V3R5 POM8367
  • V3R4 POM8110

4
BETA92 PTFs
  • Problem (function batch - cleanlist)
  • V3R5, V3R4
  • Avoid abend 0C4 at offset 4CE
  • PTFs
  • V3R5 POM8367
  • V3R4 POM8112

5
Pending BETA92 PTFs
  • Problem (function reader, reload)
  • V3R5, V3R4
  • Limit job start and end time in the range of job
    submit and read in time
  • V3R5
  • Clear destination area of dependant scan
    definition result string
  • Notify users of automatically reloaded jobs

6
BETA23 PTFs
  • Problem (function online)
  • V3R3M1, V3R4
  • Requirement 2002/0010 RFIND (PF5) through
    multiple lists
  • PTFs
  • V3R3M1 PBF1179
  • V3R4 PBF1518
  • (Beta93 - users must install PPM6122)

7
BETA92 V3R5 new features
  • File tailoring of maintenance jobs
  • Dependant scan processing
  • Incremental archive
  • TCP/IP print
  • Online settable LST keywords
  • Automatic reload
  • User defined job selection table

8
Scanning
  • Dependent scan processing
  • report unmatched
  • blank removal
  • temporary disabled
  • activate scan definition
  • deactivate after match
  • processing order is from low to high numbers

9
Scanning
  • Example input text
  • TEST ALERT MESSAGE REPORT START
  • REPORT FAILURE
  • SOME ARBITRARY H I G H L I G H T E D
  • COMPLETED

10
Scanning
  • Controlling dependant scanning
  • This scan id 20015
  • Target id 800
  • String to be returned
  • Chain name EXAMPLE
  • Next id 20014
  • End of chain no
  • Field id
  • output offset 0
  • temporary disabled no
  • report unmatched no
  • blank removal no

11
Scanning
  • Controlling dependant scanning
  • This scan id 20014
  • Target id 800
  • String to be returned
  • Chain name EXAMPLE
  • Next id 20016
  • End of chain no
  • Field id
  • output offset 20
  • temporary disabled yes
  • report unmatched no
  • blank removal no

12
Scanning
  • Controlling dependant scanning
  • This scan id 20015
  • Target id 800
  • String to be returned
  • Chain name EXAMPLE
  • Next id 20017
  • End of chain no
  • Field id
  • output offset 20
  • temporary disabled yes
  • report unmatched no
  • blank removal yes

13
Scanning
  • Controlling dependant scanning
  • This scan id 20017
  • Target id 800
  • String to be returned
  • Chain name EXAMPLE
  • Next id 20015
  • End of chain yes
  • Field id 30
  • output offset 40
  • temporary disabled yes
  • report unmatched no
  • blank removal yes

14
Scanning
Id20015
15
Automatic reload
  • LST keywords for this feature
  • B92_AUTORLD_ENABLED
  • B92_AUTORLD_SSID
  • B92_AUTORLD_INTERVAL
  • B92_AUTORLD_SETTLE_COUNT
  • B92_AUTORLD_REQUEST_LIMIT_HIGH
  • B92_AUTORLD_REQUEST_LIMIT_LOW

16
Automatic reload
  • Pragmatic view

REQUEST_LIMIT_LOW
REQUEST_LIMIT_HIGH
Number of requests
Start immediate
Start after INTERVAL
Start after INTERVAL SETTLE_COUNT
17
Single STC BETA92 EDF
  • Run only one STC
  • Selectable via LST parameter
  • B92_TCPIP_BSA_SERVER YES
  • B92_TCPIP_PORT
    (5926,WIF,10.56.72.100,TCPIP)
  • B92_TCPIP_PORT
    (5972,EDF,10.56.72.100,TCPIP)

18
BETA92 WIF
19
BETA92 WIF
20
BETA92 problem statistic
Write a Comment
User Comments (0)
About PowerShow.com