Title: Carbon therapy machine
1Carbon therapy machine
- Working group2
- FFAG workshop 2003 at KEK
2Target specification of the beam for carbon
therapy
- Beam species C6
- E 80 400MeV/u
- ltIgt 1 x 6 nA
- Repetition rate 120Hz(240Hz)
3Schematic diagram of the system
proton therapy
carbon therapy proton driver?
ion source
RFQ
DTL
booster
main ring
0.75MeV/u C6
1.75MeV/u C6 7MeV proton
62MeV/u C6 230MeV proton
400MeV/u C6 1.2GeV proton
4Plasma Target Chamber
Insulator (MC nylon)
C Target (Rotateable)
Focal Spot Size on Target Surface d 1.22f l/D
64.7 mm
RFQ
Laser Beam
Power Density P W/(p(d/2)2) 3.35 1012 W/cm2
Na Cl
H. V.
Lens
Slit 4mm
Properties of the laser plasma Energy of the ions
about 100 eV/u Emission angle less than 20
degrees
5Photo album of the experiment (Okamura RIKEN)
6Beam Spec at the end of injector
E1.75MeV/u 1E9 ppp ltIgt 115nA eN1pmm-mrad
1ms
120Hz
7Booster (radial sector)
Energy Br Ncell k Bmax tune Long
straight r excursion
1.75 62MeV/u 0.38 2.32Tm 12 12 2.0T (4.2,1.4)
0.75m 4.353 5.000m 0.647m
8Lattice functions of the booster ring ( radial
sector)
9Booster (spiral sector)
Ncell k fpack z Bmax tune Long straight r excursio
n
12 12 0.35 57 degree 1.66T (4.4, 1.3) 1.36m 3.483
4.000m 0.517m
10Lattice functions of the booster ring ( spiral
sector)
11Radial or Spiral
- Machine parameters tell spiral sector ring
preferable. - For medical use, extraction energy from the main
ring should be able to changed 70-400MeV/u. - Booster should be able to change k value.
- Can we change k in spiral lattice?
12Tunability of k in a spiral booster
13Main ring(spiral)
E Br Cirumference Ncell k fpack z Bmax tune Long
straight r excursion
62 - 400MeV/u 2.32 6.35Tm 45m 16 12 0.45 64
degree 1.97T (3.9, 1.3) 1.55m 6.62 7.16m 0.533m
14Lattice functions of the main ring
15Injection and extraction scheme
Injector
1 turn injection
booster
1 turn injection
fast extraction
massless extraction
main ring
16Booster(spiral) ring rf cavity parameters
Frequency 0.84MHz4.15MHz Acc. voltage 11.0kV
(f60) of cavities 2 Core thickness 30mm
of cores 3/cavity
410mm
17Booster ring core shape
Shunt impedance 151O/cavity RF
power 25kW/cavity Core weight 310kg/core
18Main ring rf cavity parameters
Frequency 6.62MHz7.15MHz Acc. voltage 16.0kV
(f60) of cavities 2 Core thickness 30mm
of cores 3/cavity
410mm
19Main ring core shape
Shunt impedance 118.4O/cavity RF
power 100kW/cavity Core weight 274kg/core
20Power consumption
Preinjector 350kW Booster magnet 280kW cavity
50kW Main ring magnet 800kW cavity 200kW tot
al 1680kW
21Summary
- Preliminary parameters of the carbon therapy
system have been obtained. - Spiral sector lattice seems to be ok for the main
ring and the booster considering optics and
geometrical configuration. - The main ring is very compact comparing to
existing carbon machines. C45m - The booster ring can be used as proton therapy
machine.
22Things to do
- Stability of the spiral lattice.
- Optimization of operating point
- Precise beam tracking simulation using TOSCAs
data. - Injection / extraction calculation.
- Synchronization between the booster and the main
ring - Hardware feasibility study
- - Injection/extraction kicker magnets and their
power supplies - - How to realize 2.0T B field in the main ring
- - Pole-face winding method
- - etc