Title: Power Systems 2005 Clemson University March 9-11, 2005
1 Power Systems 2005Clemson University March
9-11, 2005
- GenerLink Overview
- Background
- Product Demonstration
- Technical Review
- Installation
- Marketing SWOT
- www.generlink.com
Mark Matyac President Global Power Products,
Inc. Phone 770-736-8232 FAX 770-736-8231 mark_at_gl
obalpowerproducts.com
2GenerLink
- GenerLink allows electrical customers to safely
connect a small generator to their homes during a
power outage.
3GenerLink History
- PEPCO Technologies LLC Started in 1999
- Design, Development UL Listing in 2002
- September 11, 2001
- PEPCO Donation to EPRI
- Global Power Products 2003
4Residential Reliability Market Exists Today
- Distributed Reliability
- 10 to 15 million portable generators already
exist - Cost of Generators have come down
- Typical yearly sales are approximately 2 million
units - Three companies have 85 market share
- Coleman
- Honda
- Generac
5- Circuit Operation
- Technical Discussion
6Four Basic Switch Components
- (1) 200 Ampere ASCO Switch
- (1) 30 Ampere Siemens T-92 Relay
- (2) Siemens RTE Relays
7Basics of GenerLink
- GenerLink is a state switch
- Generator has priority
- Allows customer to test system
- Operator becomes part of the process
- Special Electromechanical logic scheme insures
break-before-make - 160 amperes continuous current flow
8Basic Circuit Overview
200 Amp ASCO Switch
Utility
Loads
ASCO Switch Control Circuit
Siemens T92 Relay
Generator Close Circuit
30 Amp Self-Reset Circuit Breaker
Yes
Tripped?
Fuse
Fuse
Close Enable
Trip Enable
Generator
Utility Sense Circuit
Generator Sense Circuit
G
Hardware Interlock
R. Stewart Pepco Technologies 9/21/99
9Protection
- Control Function designed similar to relay
protection scheme - Control Circuits are fused and transformer
isolated -
- Stuck-Switch Protection
- Hardware Interlock - Primary
- Fuse with specific I2T Value - Secondary
- Generator Over Current Protection
- Generator Breaker - Primary
- Self-resetting Circuit Breakers - Secondary
10Utilities
- Sales
- Mail marketing
- Safety seminars
- Installation
- Provide installation
11The Future
- Gateway
- Fuel Cell
- Generator
- Home Generation to Offset Peak Periods
12Product Vision
- A device that provides residential customers an
alternate means of service in the event of an
electrical power outage.
- Currently designed to fit most 200-ampere ring
and ringless meter cabinets.
13Exterior Wall
Cabinet Cover
GenerLink
Watthour Meter
Sealing Ring
200 Amp Ringless Cabinet
8/2/00
14Installation on Ringless Cabinet
- Verify numbers, record required information.
- Remove cabinet cover.
Connector
Cord Set
15Installation on Ringless Cabinet
- Replace and tighten nut.
- Plug otherend of ground wire to the
GenerLinkdevice.
16Installation on Ringless Cabinet
- Insert Watthour Meter into the GenerLink.
17Installation on Ringless Cabinet
- Install sealing ring at the GenerLink - Watthour
meter connection. - Seal cabinet and sealing ring.
- The installation is now complete.
18Installation on Ring Style Cabinet
- Plug watthour meter into the GenerLink socket.
19Installation on Ring Style Cabinet
- Replace the cabinet sealing ring.
- Install additional ring at GenerLink - Meter
connection.
20Installation Complete
- GenerLink makes connecting your home generator
as easy as using a plug and flipping a switch.
21Test Results
In-House Testing
- 300,000 Operations, No Load
- 92,586 Operations, Generator Relay, 30A Load
- 12,140 Operations, ASCO Switch, 160A Load
- 16,266 Operations, 65 - 100 Nominal Voltage _at_
185º F - 1248 Hours, Generator Input, Continuous 30A,
.76 pf - 2 Hours, 200A Continuous, 109 ºF Max Temp
- 22 Hours, 163 A, 6 Sec. Cycle, 103 ºF Max Temp
- No RFI Susceptibility
- No Effect On Meter Accuracy
22Test Results
23(No Transcript)
24Surge Suppression
- Tested 6 whole-house products with EPRI/PEAC
- Selected two manufacturers
- GPP UL Listed with Surge Protection 5/12/04
25Defined Zones of Protection for Surge Suppression
wired-in
plugged-in
TV Computer Refrigerator Microwave etc.
AC Furnace Water Heater Pumps etc.
Panel
Branch
Telco
CATV
Zone C
Zone A
Zone B
ANSI/IEEE 62.41
26GenerLink Marketing
- Strengths
- Weaknesses
- Opportunities
- Threats
27GenerLink Strengths
- Customer Acceptance
- Cost of GenerLink vs Other Transfer Switch
- Plug Play with Portable Generators
- Ease of use
- Voltage to Customers Entire Electrical Panel
- Insurance Premium Discount
28Portable Generator Market Defines Existing
Residential Reliability Market Opportunity
- Simmons Market Research 620,000 portables
purchased in 1998 (4-5 of adults own portables) - Robin/Subaru 930,000 portables sold in 1998
- Generac 1.0-1.6 million portables sold per year
1998-2000 (600-900 million sales, 16 CAGR) - RKS Research Consulting 11 of affluent
households own generator
Estimates vary, but several hundred thousand
generator units sold annually in U.S. seems
likely and growing at healthy pace
29Target Markets
Distributed Reliability
Distributed Generation
30GenerLink
- Utility
- Safety
- Integrated Surge Module
- Similar to a Meter Installation
- Quality Parts in Manufacturing
- UL Listed
- Distributed Generation
31GenerLink Weaknesses
- Consumers
- Cost Sticker Shock
- Little if any Installation Cost
- GenerLink is Shipped with Power Cord
- Utility
- What if
32GenerLink Opportunities
- Functionality
- 40 Amps
- Polyphase
- Grid Gateway
- Surge
- Zigbee Communications
33GenerLink
- Sales Scenarios
- Utility Buys and Leases
- Utility Buys and Sells to Customer
- Customer Buys and Utility Installs
- Customer Buys and Contractor Installs
Two fundamental thrusts Assemble technology
portfolio Establish distribution channels
34GenerLink Opportunities
- Acceptance
- FPL
- AEP
- NES
- Northeast Utilities
- Hydro 1
- Touch Stone Energy
- Midwest Electric St. Marys Ohio
35GenerLink Threats
- Conflict between Utility and Electrical
Inspectors - Utilities Nobody Touches My Meter
- Contractors A Ground has to be Installed
- Extension of Meter Base
36Conclusion
- Safety for Utilities
- Safety for Consumers
- Simple Installation
- Cost Effective
- www.generlink.com