The JEI, aka the Engineering Console - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

The JEI, aka the Engineering Console

Description:

1. The JEI, aka the Engineering Console. JEI Java ... No mods to this screen, just need to write any of the scripts. FLAMINGOS-2 CDR, 2003 Aug 20-21 ... – PowerPoint PPT presentation

Number of Views:62
Avg rating:3.0/5.0
Slides: 14
Provided by: astro8
Category:

less

Transcript and Presenter's Notes

Title: The JEI, aka the Engineering Console


1
The JEI, aka the Engineering Console
  • JEI Java Engineering Interface
  • Based on the T-ReCS JEI
  • Control Screens
  • MCE4 Control Params (e.g. reads, coadds, net
    Itime)
  • Detector Bias Preamp Settings
  • Temperature Pressure Monitor of the Mos Dewar
  • Pressure Monitor Temperature Monitor Control
    of the Camera Dewar
  • Mechanism High-Level (Named Positions)
  • Mechanism Low-Level (Numeric Position Control
    Parameters)
  • Scripts
  • EPICS Records
  • System

FLAMINGOS-2 CDR, 2003 Aug 20-21
2
Detector Screen (1)
  • Almost everything (e.g. nodding chopping) is
    deleted.

FLAMINGOS-2 CDR, 2003 Aug 20-21
3
Detector Screen (2)
  • Add Adjustments for
  • Single Frame Exposure Time (seconds)
  • Net Desired Exposure Time if Coadding Set
    NumCoadds
  • Number of Multiple Reads, otherwise CDS
  • CDS Readout Modes
  • output of final difference image
  • Output the individual frames that make up the
    difference
  • MCE4 Control Parameters to keep
  • Pixel Base Clock
  • Number of Pre-Resets (default 10)
  • Number of Post-Resets (default 1000)

FLAMINGOS-2 CDR, 2003 Aug 20-21
4
Bias Screen
  • HAWAII-2 array only has 1 adjustable bias voltage
    (not 24!)
  • Need 2 common biases (1) Imaging, (2)
    Spectroscopy
  • Combine with Preamp Screen (?)

FLAMINGOS-2 CDR, 2003 Aug 20-21
5
Preamp Screen
  • HAWAII-2 array readout through all 32 output
    amplifiers ? need 32 offsets.

FLAMINGOS-2 CDR, 2003 Aug 20-21
6
Temperature Pressure Screen Mos Dewar
  • Monitor Three Temperatures
  • Cold Head
  • Worksurface
  • Spare

FLAMINGOS-2 CDR, 2003 Aug 20-21
7
Temperature Pressure Screen Camera Dewar
  • Monitor Coldhead, Detector Fanout
  • Control Worksurface (2 locations) provision to
    control Detector

FLAMINGOS-2 CDR, 2003 Aug 20-21
8
Mechanism High Level
  • Modify for the following mechanisms
  • Decker, Mos, Filter-1, Filter-2, Lyot, Grism, and
    Detector Position
  • Delete Grating section

FLAMINGOS-2 CDR, 2003 Aug 20-21
9
Mechanism Low Level
  • Modify for the following mechanisms
  • Decker, Mos, Filter-1, Filter-2, Lyot, Grism, and
    Detector Position

FLAMINGOS-2 CDR, 2003 Aug 20-21
10
Mechanism Parameters
  • Modify for the following mechanisms
  • Decker, Mos, Filter-1, Filter-2, Lyot, Grism, and
    Detector Position

FLAMINGOS-2 CDR, 2003 Aug 20-21
11
Scripts Screen
  • No mods to this screen, just need to write any of
    the scripts.

FLAMINGOS-2 CDR, 2003 Aug 20-21
12
EPICS Records Screen
  • Use to monitor epics and sad records cf. ICD
    1.9.f/3.1 The FLAMINGOS-2 to OCS Interface

FLAMINGOS-2 CDR, 2003 Aug 20-21
13
System Screen
  • Modify for 2 cryo-coolers. Lakeshore 340
    replaced with model 332.

FLAMINGOS-2 CDR, 2003 Aug 20-21
Write a Comment
User Comments (0)
About PowerShow.com