Title: Workshop on Spacecraft Data Systems
1Workshop on Spacecraft Data Systems
- COTS-based activities on Spacecraft Data Systems
by IMT
- G.Perrotta, G.Cucinella
- IMT srl, Via Carlo Bartolomeo Piazza 8
- 00161 - Rome, Italy
- e-mail imtsrl_at_iol.it - URL www.imtsrl.it
2IMTs activities
- The on-going IMTs activities on Spacecraft Data
Systems are - - a COTS-based on board computer
- -a COTS-based multi-terabyte RAID system.
3The On-Board Computer
- The initial IMTs idea of building an OBC with
COTS boards was sponsored by ESA through a
contract (N.13409/98/NL/MV) which enabled to test
the radiation and environmental endurance
capabilities of motherboards made by two
different Italian vendors leading to the
selection of one. - The success of this contract led to an ASI
contract (N. I/180/01/0 as co-funding) for the
realisation of a full COTS-based On-Board
Computer (OBC) including the updating of the
motherboard, the addition of the I/O and SCC
(synchronous Serial Communication Controller)
boards, and of the additional 1GB mass memory
(based on flash EPROMS).
4The On-Board Computer - The OBC features
- PC/AT architecture, efficiently packaged on PC
104 cards. It includes an ELAN 520 133 MHz CPU
board by SECO (an Italian PC104 boards Supplier)
provided with 32 MB DRAM. - Memory card with a Flash EPROMS of up to 1 GB
memory. - Board providing two full-duplex high speed serial
channels. - I/O board providing 16 analogue input channels, 2
output channels, 88 in/out digital signals, 2
timers and high precision voltage references
temperature compensated.
5The On-Board Computer - The OBC features
- OBC mass is 0.7 kg
- Power drain of 5 W _at_ 5V.
- The unit can withstand up to 10 Krads
- Operating temperature range 20C to 60C.
- The OBC has a QNX operating system, but full
compatibility with other O.S. has been proven in
our Labs. - All applications SW are written in C, but we
have tested the compatibility with other
low-level languages.
6The On-Board Computer
SCC Board
Mother Board
Mass Memory
ADC Board
7The On-Board Computer
130 mm
8The On-Board Computer Environmental Testing
- The OBC has been subjected to radiation and
environmental tests (vibration, thermal and
thermal-vacuum) with success.
9The On-Board Computer Environmental Testing
The Hardware during irradiation
Radiation withstanding up to 10 Krads
10The On-Board Computer Environmental Testing
The OBC during vibration test
Vibration test performed according to the
applicable ECSS-E-10-03A standard (qualification
level)
11The On-Board Computer Environmental Testing
The OBC during Thermal Cycles test
47 Thermal Cycles performed according to the
applicable ECSS-E-10-03A standard (qualification
level) -20C to 70C
12The On-Board Computer Environmental Testing
The OBC during Thermal Vacuum test
Thermal Vacuum tests (8 cycles) performed
according to the applicable ECSS-E-10-03A
standard (qualification level) -20C to 70C
13The On-Board Computer - Applications
- Besides its use as the core OBC on board nano,
micro and minisatellites, we intend to propose
the OBC as a navigation computer on launch
vehicles and for general computing and TLC/TLM
handling purposes for scientific missions both on
free-flyers and on the Space Station.
14The Mass Memory (HDCOTS)
- The COTS-based RAID (Redundant Array of
Independent Disk Driver) system originated from a
market survey showing the absence of makers of
spaceborne RAID systems in Europe while such
devices have been used on several USAs space
missions. Considering the push from the consumer
and professional market towards decreasing prices
and the continuous technical evolution of the
hard disk technology, it seemed logical to
undertake the development of a RAID system
looking in prospective to the ever increasing
storage capacity of Earth Remote Sensing
satellites equipped with optical or radar
instruments.
15The Mass Memory (HDCOTS)
- The RAID system consists of a stack of hard disks
inclusive of the RAID controller and interfaces
with an external computer. The RAID system will
be capable of up to 8 pairs of hard disks each
with 73 GB capacity (for a total of 1.2
terabytes). A last-generation SCSI interface is
adopted to speed up the write/read performance,
which is further enhanced by the inherent shared
operation of the RAID system. - This RAID intends to compete, in terms of cost,
mass and power consumption, with the equivalent
solid-state products available on the space
market. The target applications address mainly
the bulk temporary storage of remote sensing
images, in the visible, hyper-spectral or radar
bands.
16The Mass Memory (HDCOTS)
- The product is under development in the frame of
the ASI contract (N. I/030/02/0, as co-funding). - It is an High-Capacity Hard-Disk Memory based on
the extensive usage of COTS (Commercial-Off-The-Sh
elf) - HDCOTS. - IMT partners in the development are Alenia Spazio
(for the User Reqs definition) and Laben (for
Final Testing). - Possible applications are space applications in
LEO, avionics and military applications. The
HDCOTS is composed by 2 counter-rotating Disks in
a pressurised box with suitable provisions
against vibrations. - Main characteristicsCapacity 146
Gbytes (expandable) - Ultra-wide SCSI interface BUS 16 Bits Transfer
Speed about 40 MB/sec Mass less than 2.5 Kg
((for the baseline). Power consumption in the
order of some tens of watts. Program completion
forecast December 2003
17The Mass Memory (HDCOTS) - General Requirements
- Reduced dimensions and mass
- Reduced costs w.r.t. the Solid State Mass
Memories - Reduced Power consumption
- (Extensive usage of COTS
- Expandable Capacity gt 1 TB
- Transfer Speed gt 10-20 MB/sec
- PC Standard Compatible interface
18The Mass Memory (HDCOTS) System Architecture
- The Technological Demonstrator (TD) is a
High-Capacity Memory system for space application
at low cost. It is composed by memory devices and
control electronics in a single box the power
supply can be a separated unit. - The Hard Disks are the ideal solution for the
implementation of the TD. From space application
point of view it implies - - the TD shall be composed by 2 counter-rotating
Disks to give a resulting null angular momentum
to the satellite during read/write operations - - the TD shall be maintained in a pressurised box
such as the internal pressure does not go down to
the minimum required by the disk heads since they
work on an air cushion.
19The Mass Memory (HDCOTS) - Architecture
- To increase significantly the capacity,
modularity and reliability of the memory system,
a RAID (Redundant Array of Independent Disk
Driver) architecture will be implemented, by
using a single control electronics to manage all
Disks. Of course, the system will be composed by
a multiple of 2 Disks, formed by a pairs of
counter-rotating Disks. - The TD, as demonstrating model, will be a RAID
system reduced to the minimum, formed by a single
pair of counter-rotating Disks and a control
electronics.
20The Mass Memory (HDCOTS) - Architecture
- As far as the Disks, the SCSI technology has been
selected, because the high read/write speed. In
addition the significant number of Disks that can
be managed will be useful for the development of
more complex RAID system. - For the TD, Disks with Ultra 160 SCSI interface
have been selected, because it is a consolidated
standard at low cost w.r.t. the very new Ultra
320. For the Disks we have considered a capacity
greater than 40 GB, more than adequate for the
current market and applications requirements.
21The Mass Memory (HDCOTS) - Architecture
- The control electronics shall allow the
management of the Disks RAID configuration and
shall perform interface functions versus the
remote computer at similar speed than the
transfer speed of the Disks. Such electronics
shall be an Ultra 160 SCSI Controller plus a
communication interface versus the remote
computer. - The additional interface shall foreseen a PCI
slot, at least, compatible with the controller
in addition an expansion cable versus the remote
computer is necessary.
22The Mass Memory (HDCOTS) - Architecture
23The Mass Memory (HDCOTS) Electrical Design
- For the interface of the TD and the remote
computer the selected solution is from MAGMA,
named PCI Expansion.
24The Mass Memory (HDCOTS) Electrical Design
- The selected Hard-Disks are
- IBM Ultrastar 73LZX
- Maxtor 73G Ultra 160 SCSI
25The Mass Memory (HDCOTS) Electrical Design
- The SCSI Controller will be selected as results
of the evaluation tests performed on the two
chosen types.
26HDCOTS TD mechanical Design
27HDCOTS TD mechanical Design
28HDCOTS TD mechanical Design
29The Mass Memory (HDCOTS) EM Test Bench
30The Mass Memory (HDCOTS) EM Test Bench
31The Mass Memory (HDCOTS) EM Preliminary Test
32The Mass Memory (HDCOTS) The Electrical Model
PCI expansion
SCSI Controller
Disk 1
Disk 2
Disk 3
33The Mass Memory (HDCOTS) IBM HD
34The Mass Memory (HDCOTS) Maxtor HD
35The Mass Memory (HDCOTS) FFD UWSCSI M-Systems
36The Mass Memory (HDCOTS) SCSI Controller
37The Mass Memory (HDCOTS) PCI Expansion
38AIV Plan Preliminary COTS Verification
To be performed on Electrical Model
Radiation Test
Yes
Yes
Temperature Cycles
Unit Verifications
OK
OK
To be performed on TD
No
No
COTS Selection
39AIV Plan Electrical Model Verifications
Preliminary Functional Verifications
Yes
Yes
Expected performances verifications
Radiation Test
OK
OK
No
No
Electrical Design modification
40AIV Plan Validation Testing
Structural Model Vibration Test
Tests on TD
Thermal Cycles -20C 60C
Yes
Yes
Vibrations
Thermal vacuum -20C 60C
OK
OK
No
Yes
No
OK
Yes
OK
No
Mechanical Design modification
Electrical/ Mechanical Design modification
No