1
FS30 Cold Carbonation
2
Principles of Carbonation
CARBONATION
Soda Out
CO2 In
  • CO2 gas pressure in maintained in
  • the carbonator tank.

Water In (70psi)
2. Water pressure of 70psi enters the
carbonator pump.
  • When probe recognizes low water
  • level in tank, pump motor cycles
  • to fill tank.

4. Water is pumped into tank through an
orifice (to create a spray for maximum CO2
absorption) until water level reaches high
probe level, then pump motor shuts off.
Carbonator Probe
Carbonator Pump
Carbonator Tank
Carbonator Motor
3
COLD CARBONATION
Carbonator Motor
Carbonator Tank
Pre-chill Circuit
Tank inlet
Carbonator Probe
Carbonator Pump
Carbonator Tank is embedded in Cold Plate
4
CARBONATOR TANK
Tank Capacity 100oz. CO2 Area Capacity
10oz. Probe Area Capacity 20oz. Reserve
Capacity 70oz.
Picture Frame Carbonator Tank
Cold Carbonation occurs when the carbonator tank
is located in a cold environment. In this case
the carbonator tank is embedded in a cold plate
covered with ice. Cold carbonate
5
CARBONATOR
Carbonator Relief Valve
Carbonator Probe
ORIFICE
Water Level
PROBES
COLD PLATE SITS ON 10º ANGLE PITCH
6
COLD PLATE
OUTLETS FOR CARBONATED WATER
OUTLETS FOR PLAIN WATER
Out
WATER INLET TO CARBONATOR PUMP
10º Pitch front to back
WATER INLET FOR PLAIN WATER DRINKS
Carbonator Probe
SYRUP INLETS
CARBONATOR PROBE FITING
7
CARBONATOR PROBE
Plugs into Main Board
White
Black
Carbonator Probe
Reading
Green
Note Probe reads between black and green wires
Carbonator Probe
8
CARBONATOR MOTOR AND PUMP
Backflow Preventor
RELIANCE 1/4 HP Motor 115 Volt/60HZ
3.4 Amp 1675 RPM
100 GPH
Anderson Watts Brass
Clamp
Carbonator Pump
9
Pump Operation
CARBONATOR PUMP
Water In (40 to 70psi)
Water Out
Preset at 250 psi DO NOT READJUST
To prevent the pump from over-pressurizing the
carbonator tank, the pump has a
built in by-pass chamber to circulate water in
excess of 250psi.