Why did Lely develop a watchdog?
4
Why did Lely develop a watchdog?
  • Automatic transfer between bulk tanks
  • Trace-ability and monitoring
  • Lack of visual inspection in 24 Hour process.
  • Many countries seeking improved monitoring
    devices.
  • Validation cleaning process.
  • Food safety important for Lely.

5
Goals
  • Check and store data in regard to
  • Milk tank-cleaning
  • Milk line-cleaning
  • Milk temperatures etc. in Bulk Tanks
  • Conductivity of cleaning/sanitising solutions
  • Give ready signal to start milking
  • Give alarm signal if anything fails
  • Tamper proof continuous monitoring
  • For robotic and conventional systems

6
Pre-requisites
  • For use around the Globe.
  • No welding on tanks etc.
  • Reliable.
  • Users ready for new regulations and legislation.
  • Measure results direct.

7
Validation of the hygiene-process
  • Validation through indirect parameters like
  • Has cleaning taken place?
  • Concentration detergents?
  • Temperature cleaning-process?
  • Time of the cleaning-process?

8
Validation of the hygiene-process
  • Means that the real measured values are compared
    with the reference values and in case of
    variations beyond the tolerances
  • Generate alarm
  • Register and store alarm in memory

9
Monitoring the cleaning and production process
  • hand-shaking production- and cleaning-process
  • Guard cleaning-process for
  • Important parameters
  • Concentration
  • Temperature
  • Time
  • Guarding production-process temperature bulk tank
    (too low/high)
  • Agitator bulk tank

10
Synthesis between the 4 essential factors
Concentration
Temperature
Mechanical forces
Contact time
11
Functions
  • Monitoring cleaning milk line
  • Monitoring cleaning milk tank
  • Monitoring cleaning buffer tank
  • Monitoring milk tank /buffer tanktemperature
    time/cleaning solutions/ agitation valve
    positions

All functions are not yet possible for all
configurations.
12
Guard Cleaning milk line
  • Measures time temperature,conductivity valve
    positions
  • Detects cleaning phase (pre-, main- post-)
  • Alarms if
  • Times of phases are out of setting
  • Temperature of phases are out of setting
  • Pre-cleaning temp.
  • Main-cleaning temp.
  • Post-cleaning temp.
  • Valve is in tank-position during cleaning

All functions are not yet possible for all
configurations.
13
Guard cleaning milk tank
  • Measures temperature, conductivity,
    agitator-function
  • Detects cleaning phase (pre-, main-, post-)
  • Alarms if
  • Times of phases are out of setting
  • Agitator is off during cleaning
  • Tank is not empty after cleaning
  • Milkline valve is in tank position
  • Conductivity is out of range

All functions are not yet possible for all
configurations.
14
Guard cleaning milk tank Buffer Tank
  • Alarms if
  • Temperature of phases are out of order
  • Pre-cleaning temp.
  • Main-cleaning temp.
  • Post-cleaning temp.
  • Conductivity of the different phases are out of
    order
  • Pre-cleaning conductivity water-condition
  • Main-cleaning conductivity gt 0,5 solution
  • Post-cleaning condition water-condition

All functions are not yet possible for all
configurations.
15
Guard cleaning milk tank Buffer Tank
  • Ready signal if
  • Milk tank is empty AND cleaning is okay
  • Tank valve is closed
  • Milk line valve is in tank position

All functions are not yet possible for all
configurations.
16
Guard milk tank/buffer tank
  • Measures temperature, empty tank,
    agitator-function
  • Alarms if
  • Temperature is out of range
  • Agitator switched off too long
  • Empty tank too long
  • Milk line valve in sewer position
  • Milk tank valve open more then 30 sec.

All functions are not yet possible for all
configurations.
17
Guard milk tank/buffer tank
  • DO NOT LOAD when
  • Temperature is out of range
  • At power-failure of Hubble (7 hours, temp.
    gt5,5C)
  • At system-failure of Hubble
  • Measures milk tank valve
  • When the milk tank is unloaded, gives alarm if
  • Milk flows into milk tank after redirecting milk
    flow
  • Tank valve is opened before milk flow is
    redirected

All functions are not yet possible for all
configurations.
18
Memory
  • Data stored in memory
  • Max. cleaning temperatures
  • Max. conductivity
  • Date and time-period of cleanings and agitator
  • Milk-temperature each 15 min. (adjustable)
  • Alarm descriptions with date and time-period

19
Memory
  • Data stored is not erasable, and can not be
    manipulated
  • Memory retains data also after lightning etc.
  • Data stored for 6 months, than overwrite of first
    data

20
Data Display
  • Cleaning-temperature C
  • Milk-temperature C
  • Cleaning-conductivity mS/cm
  • Agitator ON/OFF indicator
  • Arrow shows temperature rise/fall

21
Data visualisation
  • See all stored data
  • Temperature, conductivity, alarms
  • Change all settings
  • Customer , time/date, parameters
  • Change configuration (protected)
  • Which milk tank system
  • Calibrating functions

22
Data visualisation with Hubble Manager software
  • Connecting the Hubble to PC (RS232)
  • Download data
  • See all stored data, settings, configurations
  • See graphs of
  • Temperature of milk tank
  • Temperature of cleaning milk line
  • Temperature and conductivity of cleaning milk
    tank
  • Real time milk tank temperatures

23
(No Transcript)
24
(No Transcript)
25
(No Transcript)
26
(No Transcript)
27
(No Transcript)
28
(No Transcript)
29
(No Transcript)
30
Sensors
  • Sanitary construction
  • In accordance with required accuracy
  • Industrial proven reliability

31
Sensors
  • Conductivity / Temperature

32
Sensors
  • Level

33
Sensors
  • Temperature

Low reaction time ( small t)
34
Installation
  • Installation of Hubble, sensors, cables
  • Start-up with learning period
  • To learn farmer specific data like
    times/temperature conductivity of cleaning
  • Alarms will be stored but not activated
  • After 2 weeks evaluate settings, change if
    necessary.
  • Every year recalibrate sensors

35
Build with standard prints and contacts
36
Wiring scheme.
37
Operation
  • See all data on display/PC
  • At alarms
  • Alarm LED and alarm buzzer switched on
  • Reset alarm pressing a key (buzzer off)
  • Solve problem
  • Accept alarm by pressing a key (LED off)
  • If no ready signal to robot
  • Robot will not start because cleaning not okay

38
To summarize
  • We believe to have build the most advanced
    Watchdog to guard the hygiene and storage of
    milk.
  • Flexible in the use and customizing
    possibilities.
  • Meeting the demands from modern industries that
    aim at HACCP structures.