FDGPETCT Technical Committee - PowerPoint PPT Presentation

About This Presentation
Title:

FDGPETCT Technical Committee

Description:

This biomarker shall be of known precision and accuracy when used in single- and ... blood glucose, time, fasting time, hydration, physical activity, FDG uptake time ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 10
Provided by: lindabr1
Category:

less

Transcript and Presenter's Notes

Title: FDGPETCT Technical Committee


1
FDG-PET/CT Technical Committee
  • May 19-20, 2009

2
Overall Claim
  • Quantitation, both single point and
    longitudinal, of tumor metabolism via FDG-PET/CT
    that can be used practically and efficiently as a
    biomarker. This biomarker shall be of known
    precision and accuracy when used in single- and
    multi-center, multi-vendor clinical trials and
    meta-analyses, enhancing its potential for use in
    patient care and qualification for use in
    clinical studies of pathophysiology and
    therapeutic interventions.
  •  
  • measuring change over time (e.g., pre- and
    post-treatment in a clinical trial of an
    investigational agent or for refinement of
    patient care during a course of therapy.

3
Digital Reference Object
  • Can find in the DICOM header reliable data
    required for SUV calculation
  • Short-term single standard stack, multiple
    vendors
  • Mid-term validate receiving workstations with
    vendor-specific stack with header and
    standardized SUV truth values (sample data)
  • Long-term raw data--validate image generation
    beyond acquisition point AND receiving workstation

4
FDG-PET Covariates
  • Completed description of rationale, limitations,
    and proposed solutions for patient weight,
    height, injected activity, blood glucose, time,
    fasting time, hydration, physical activity, FDG
    uptake time (based in part on NCI guidelines)
  • General proposal is to
  • Improve and standardize measurements affecting
    SUV quantification (e.g. time, weight)
  • Embed results in public DICOM tags of patient
    study
  • Display results on viewing and analysis
    workstations (glucose, FDG uptake period)

5
Software Version Tracking
  • Can create, store, retrieve FDG-PET/CT images
  • Stage 1 Manually record the SW version number
    and flag the impact on quantitation
  • Stage 2 Record all SW Version numbers in DICOM
    header

6
Quality Control
  • Completed description of rationale, limitations,
    and proposed solutions for CT and PET calibration
    and quality control
  • Propose that vendors make QC results (only
    pass/fail/warning) and calibration results (mean,
    variance) readily accessible as external files or
    ideally incorporated in the public DICOM tags of
    each patient study

7
ROI
  • Claim Can create, store and retrieve markups of
    SUV measurements in accordance with a standard
    definition for RoI that provides a known balance
    between precision and accuracyPrecursor
    Survey of vendor to assess ROI tools and
    algorithms currently available to determine
    whether current methodologies can be defined on
    current systems and make recommendations to
    vendors for ROI in the future.

8
ROI
  • Improve the max-pixel method by additionally
    reporting the mean of a pre-defined cluster of
    neighboring pixels
  • For a given pixel cluster, use for calculated a
    mean value (equivalent to smoothing the image
    with a kernel based on this luster shape and size
    and reporting the maximum pixel value within a
    broad user-defined region)

9
ROI - future
  • Anatomically based ROIs to provide objective
    means of measuring FDG uptake within larger
    volumes
Write a Comment
User Comments (0)