Title: DataLogger Product Training
1DataLoggerProduct Training
2Index
Jump to
- Product Identification
- Product Set-up
- Data Logging Procedures
- Data Analysis
- Troubleshooting
Jump to
Jump to
Jump to
Jump to
3Revolutionary Change
- Replaces the DL2001/2002
- Improved user interface (MS Windows)
- Wireless connectivity
- Compact design
- 2 versions available
- New reduced pricing
Return to Index
4Product Overview Standard Offering
The DataLogger Unit
The Pocket PC
5Product Overview Ruggedized Offering
The DataLogger Unit
The Ruggedized Pocket PC
6Operators Manual
- An Operators Manual is shipped with each unit.
- Carefully read this manual and heed all
instructions before operating this unit.
7The Standard DataLogger Complete Package
The standard DataLogger is shipped is a yellow
plastic case and is shipped with the following
components
- - Connecting Fitting Kit
- 1 MFC00113 Elbow
- 1 MFA00204 Adapter
- 1 MFA00205 Adapter
- 1 MFB00201 Swivel Connector
- 1 MFH00048 Quick Disconnect Adapter
- Pocket PC Manufacturers Manual
- SD Card (loaded in Pocket PC)
- Ear Bud headset
- Pocket PC Wrist Strap - DataLogger - 2 D
cell batteries - Pressure Transducer - AC Adapter
(charger) - USB Cable (connect Pocket PC to a
computer) - SD Card Reader - USB Cable (connect
card reader to a computer)
8A View of the Components
9Plastic Carrying Case
Operators Manuals (both McElroy OEM)
SD Card Reader
Connection Fittings
Connector Cables (USB) AC Adapter (Charger)
Batteries
Pressure Transducer
Pocket PC
DataLogger
10The Ruggedized DataLogger Complete Package
The standard DataLogger is shipped is a yellow
plastic case and is shipped with the following
components
- - Connecting Fitting Kit
- 1 MFC00113 Elbow
- 1 MFA00204 Adapter
- 1 MFA00205 Adapter
- 1 MFB00201 Swivel Connector
- 1 MFH00048 Quick Disconnect Adapter
- Ruggedized PC Manufacturers Manual
- Ruggedized PC - DataLogger - 2 D cell
batteries - Pressure Transducer - AC Adapter
(charger) - USB Cable (connect Ruggedized PC to a
computer)
11Plastic Carrying Case
Operators Manuals (both McElroy Recon)
Connection Fittings
Connector Cables (USB) AC Adapter (Charger)
Batteries
Pressure Transducer
Ruggedized Pocket PC
DataLogger
12BasicsGetting Started with the Pocket PC
- A. Check to ensure the battery is installed (Std
unit only) - Remove the battery cover from the back of the
pocket pc, insert the battery and replace the
battery cover - B. Charge the Pocket PC Always do this!
- Connect the AC adapter (charger) to the
Pocket PC, plug the charger into a 110V ac
outlet and allow to fully charge, it takes about
4 hours - C. Power on
- Press the Power Button to turn on the unit
Return to Index
13BasicsGetting Started with the DataLogger
- Install the batteries in the DataLogger
- Remove the battery cover from the top of the
DataLogger, insert the 2 D cell batteries and
replace the battery cover - Press the Multifunction Switch to turn the
DataLogger on
14DataLogger LED Status Indicators
Once the batteries are installed and the
multifunction switch is pressed 2 led lights will
illuminate
- Blue
- Flashing indicates the Bluetooth is ready to
communicate with the Pocket PC - Steady indicates the Bluetooth has established
communication with the Pocket PC - Tri-Color
- Amber will only stay on less than 2 seconds,
indicating power-up initialization state - Flashing Green indicates normal operation mode
- Flashing Red indicates data logging mode (active
data transfer)
15Pressure Transducer Connection
- The Pressure Transducer is connected to the
DataLogger via a cable. - The Pressure Transducer taps into the hydraulic
system of the fusion machine using the supplied
connection fittings and quick disconnect
16McElroy DL3-PPCData Logging Software Program
- Factory set-up, so its ready to log data
- Provides a user (MS Windows like) interface and
joint reporting storage capability - Uses an removable Secure Digital (SD) card for
data redundancy on the standard Pocket Pc - Uses an Compact Flash (CF) card for data
redundancy on the Ruggedized Pocket Pc
17Pocket PC Date and Time Settings
- The date and time must be checked and correctly
set to ensure accurate records of fusion joints - Turn on the Pocket PC
- Tap Start Settings
- Tap the System tab
- Tap Clock Alarms
- Select the appropriate time and/or date field and
adjust the values until they are correct - It is a good habit to periodically check the
time and date to ensure they are correctly set
(double tap the time display) -
Display Screen
B.
Display Screen
C.
Display Screen
D.
Display Screen
E.
Display Screen
F.
18McElroy DL3-PPC Program
- To initiate the DL3-PPC program
- Start Program
- Start McElroy DL3-PPC
- The McElroy DL3-PPC program starts by displaying
the DataLogger logo screen
A
B
C
Return to Index
19Use of the DataLoggerto Log a Joint
- Attach the DataLogger to the Machine
- Use the connector kit provided to attach the
DataLogger to the hydraulic system of the
machine - Power-up the DataLogger
- Power-up the Pocket PC (iPAQ or Recon)
- Use the DataLogger to measure the heater
temperature - Aim the DataLogger at the heater plate, press
the black button and move the DataLogger toward
the heater until the 2 red dots merge into one
20Preparing the Pocket PC to Log a Joint
- Tap the Menu button located in the lower
left-hand corner of the screen - Tap the Log/Status menu item to open the
Log/Status dialog box
21Preparing the Pocket PC to Log a Joint
- The Log/Status dialog box Provides status info
including PPC battery level, DataLogger battery
status, pressure transducer and temperature
readings and logging status - Tap the Connect button to initiate a connection
with the DataLogger before continuing
22Preparing the Pocket PC to Log a Joint
- The Check DataLogger dialog box is displayed
- Make sure the DataLogger is turned on
- Tap OK to continue
- Tap the device that you wish to connect to
(MDL3-0001) - The PPC will connect with the device selected
23Preparing the Pocket PC to Log a Joint
- Tap in the ID Field to input the Machine ID
(serial will work) - Tap in the Model field to select the Machine
Model (drop box) - Tap Next to continue to the Operator Screen
- Tap in the Operator ID field to enter Operator
number - Tap in the Job field to enter the Job Number
- Tap Next to continue to the Pipe Screen
24Preparing the Pocket PC to Log a Joint
- Tap in the appropriate field to select pipe
material, size and wall thickness from the drop
down boxes - Tap in the Interfacial Pressures fields to enter
the appropriate pressures - Tap the Next button to continue to the Notes
(optional) dialog box
25Preparing the Pocket PC to Log a Joint
- Tap the Next button to continue to the Drag
Pressure dialog box - Tap in the Drag Pressure and enter the drag
pressure or tap next to accept the default value
of 30 PSI - Tap the Next button and a dialog box will display
the recommended gauge pressures
26Using the DataLogger to Measure and Record Heater
Temperature
- Tap the Next button to continue to the Heater
Temperature dialog box - To measure heater temperature, hold the top of
the DataLogger about 4 inches for the heater
plate, pointing the temp sensor at the heater
plate. Press and hold the DataLogger switch,
which turns on the guidance lasers. Adjust until
the 2 laser beams converge to a single point. Use
the PPC screen to read the temperature
27Using the DataLogger to Measure and Record Heater
Temperature
- Once the temp is stable, release the DataLogger
multifunction switch to record the temperature.
- Notice the temp box flashes to indicate recorded
temperature
28Using the PPC to Initiate the Data Logging
Process
- Tap the START button on the Pocket PC to initiate
the data logging process - Note The is a slight delay (3-5) seconds as the
software sets up the procedure. Watch the PPC
and wait for the STOP WATCH to begin before
closing the carriage on the heater
29Using the PPC to STOP the Data Logging Process
- Follow the prescribed methods to heat, fuse and
cool the pipe. - Once the pipe fusion processes are complete Tap
the STOP button on the PPC to complete the data
logging process. Note Always stop logging
before opening the carriage. Otherwise, an
unintended change in pressure will be introduced
at the end of the joint report graph
30Downloading the Joint Report into the Pocket PC
- Once you have confirmed the STOP command, a
dialog box will appear that shows that Logging
stopped - Next the program will automatically begin the
process of downloading the joint report into the
PPC. Note Do not turn-off the DataLogger or
the Pocket PC until the download is complete.
31Reading and Analyzing Data
1a.
1b.
- The joint report will be displayed upon the
completion of the download. - 1a and 1b presents information related to the
joint, e.g. date, joint number, operator, etc. - 2 presents the front end plot which shows the
shift-sequence into the soak cycle. The summary
plot shows the entire fusion process from
end-to-end.
2.
Return to Index
32Reading and Analyzing Data
Joint Made Using Improper Procedure
- The Front-end Plots shows the result of a fusion
that was made incorrectly. The plot highlights
the occurrence of a bad shift sequence. The plot
indicates that the pressure dropped off too
slowly - The Summary Plot shows that the rest of the
processes followed were OK. Unfortunately the
joint is bad due to the incorrect shift sequence,
it will need to be cut out
33Reading and Analyzing Data
Joint Made Using Proper Procedure
- The Front-end Plot shows the result of a fusion
that was made correctly. The plot indicates that
the pressure dropped off Correct - The Summary Plot shows that the rest of the
processes followed were OK.
34Trouble Shooting
- Bluetooth Connection
- iPAQ power-up
- DL-3PPC Program
Return to Index
35Com-Port Setting
- If the PPC indicates that Bluetooth is turned on
you should check these setting to ensure that the
communications between the PPC and the DataLogger
is set to the correct COM port (COM6)
36Trouble ShootingThe Bluetooth Radio
Communications
- Check to see if the Pocket Pc Bluetooth radio is
turned on... The HP iPAQ rx 3115 Pocket PC has a
Blue LED on the top left corner, it should be lit
and the wireless icon should appear in the lower
right corner of the screen (circled in red). If
the Bluetooth radio is not on perform the
following steps - A. Tap Start iPAQ Wireless
- B. Tap on the Bluetooth icon to turn it on
- C. The operation is complete, Bluetooth is
turned on
Display Screens
Display Screens
37Return to Trouble Shooting BT slide
A
B
38Bluetooth On
39Steps To Follow ToRestore the McElroy DL3-PPC
Program
- Tap on Start to display the main menu
- Install the DL-3 PPC application (program)
- Tap Programs tab File Explorer
- Tap on the Pocket PC Icon next to My Documents
(Green Arrow) - When the drop down menu appears, tap on My Device
- Tap on the SD Card or Storage Card
- Tap on the PPC Setup Files folder
- Tap on the DL-3 PPC Setup file to install the
program - The setup program will run automatically and
display the installation progress
a.
Display Screen
b.
Display Screen
c.
Display Screen
d.
Display Screen
e.
Display Screen
f.
Display Screen
40Check out our website for the latest information.
www.mcelroy.com
Get your free product catalog reference guide.
www.mcelroy.com/catalog
41Return to Date Time slide
First Tap Start.
B.
42Return to Date Time slide
C.
43Return to Date Time slide
D.
44Return to Date Time slide
E.
45Return to Date Time slide
F.
46Return to Steps slide
a.
47Return to Steps slide
b.
48Return to Steps slide
c. d.
49Return to Steps slide
e.
50Return to Steps slide
f.