Title: Scaleupdown
1Scale-up/down
- Scale-up
- For the optimum design of a product-scale
fermentation system ( ), the data on a
small scale ( ) must be translated to
the large scale. - The fundamental requirement for scale up is that
the model and the prototype should be
to each other. - Two kinds of conditions must be satisfied to
ensure similarity between the model and the
prototype. - similarity of the physical
boundaries - - similarity of the flow fields
2Scale-up/down
- Scale-up
- Geometric similarity of the physical boundaries
- - of reactor
- - all linear dimensions of the model must be
related to the corresponding dimensions of the
prototype by o
. - i.e. Keep the ratio of the height H to diameter
Dt (tank) same in the model and prototype. - Normally H/Dt is 23.
Scale-up factor
Ratio of surface to volume decreases during
scale-up.
3Example Scale-up
- 2 litre cylindrical tank (Vm) is scaled up to
2000 litre (Vp) fermenter by geometrical
similarity, H/Dt2, impeller diameter Di,m 3.24
cm, what are the dimensions of the model (Hm,
Dt,m), and prototype (Hp, Dt,p, Di,p)?
4- Scale-up
- Dynamic similarity of the flow fields
- To achieve dynamic similarity in a stirred-tank
reactor, scale-up can be based on the following
criteria in addition to geometric similar
boundaries. -
- constant power input per volume . or
- constant liquid circulation rate inside the
reactor . - (pumping rate of impeller per unit volume)
- constant impeller tip speed (shear) .
- constant Renolds number .
- V working volume
- P0 energy input (W) N impeller speed (rpm)
? density (kg/m3) - Di impeller diameter (m),30-40 of the diameter
of the tank (Dt)
5- Scale-up
- Relating the above criteria to impeller diameter
Di and - speed N
(Perrys Chemical Engineers Handbook, 7th Ed.
Page.18-11)
6Scale-up/down
- Scale-up
- In scale-up of a stirred-tank reactor, the design
calculations are as follows - Determine the
. - Calculate the dimensions of the prototype (height
H and diameter Dt of tanks, impeller diameter Di)
by multiplying that of the model
. - Select criterion related to
properties and keep it constant in both the model
and the prototype. - Determine the parameters such as
or diameter for the scale-up reactor.
7Scale-up
For an example, 2 litre vessel (Vm) is scaled up
to 2000 litre (Vp) fermenter, (H/Dt)model2,
impeller diameter Di,m is 3.24 cm, impeller speed
Nm is 500 rpm, what is the impeller speed of the
larger reactor for - constant impeller tip
speed - constant Renolds number
8Scale-up/down
- Scale-down
- To provide an experimental system at a smaller
scale that duplicates the environment that exists
at the larger scale. - Mimic the production facilities at a smaller
scale - Parameters can be tested more quickly and
inexpensively than at the production scale. - Design calculations used in scale-down are the
same as that in scale-up. - Please read the example 10.3
9Immobilized Cell System
- Immobilized cells
- Provide high cell concentration
- Reuse cell
- Eliminate washout problem at high dilution rate
and cell recovery - May provide favorable microenvironmental
conditions - May prove genetic stability
- Protect against shear damage
- Can perform multi-step biosynthesis reactions
that are not practical purified immobilized
enzyme preparation. -
- Disadvantages
- Diffusional limitation are important.
- Growth and gas evalution may lead to significant
mechanical disruption of the immobilizing matrix.
10Immobilized Cell System
- Immobilized methods
- - immobilization of cells
- Entrapment and Binding
- similar to immobilized enzyme except covalently
binding (toxic agents, e.g. glutaraldehyde) - - immobilization of cells
biological film. - Multi-layer growth of cells on solid surface.
- e.g. common in biological waste water treatment
and mold fermentation - thick biofilm high concentration but diffusion
problem - Bioreactor consideration
- - hydrodynamic shear packed-column,
fluidized-bed or airlift reactors.
11Bioreactor Operation Consideration
- Mixing - Agitation and Aeration
- To provide adequate mixing of its contents is
one the most factors to consider in design a
fermenter. - - to disperse the air bubbles
- - to suspend the organism cells
- - to enhance heat and mass transfer in the
medium - providing mixing
- providing oxygen and mixing in
aerobic systems
12Scale-up
stirred-tank reactor
bubble column
jet loop reactor
airlift loop reactor
propeller loop reactor
13Bioreactor Operation Consideration
- Some basic bioreactor types for aerobic
cultivation of suspended cells - Reactors with Internal mechanical agitation.
- high KLa, flexible, medium with high viscosity
- Bubble column relying on gas sparging for
agitation - must avoid plugging of spargers
- Loop reactors mixing and liquid circulation are
induced by the motion of an injected gas, by a
mechanical pump, or by a combination of the two. - similar to the above.
14Bioreactor Operation Consideration
- - Internal mechanical Agitation
- Rushton impeller impeller diameter 30-40 of
the tank diameter, 1980s -
- Axial flow system hydrofoil impellers
- increasingly popular
-
- Baffle to augment mixing and gas dispersion
15Bioreactor Operation Consideration
- Volumetric oxygen mass transfer coefficient
determination - Unsteady state method
- An examined reactor filled with pure water or a
medium, no organism cells.
16Bioreactor Operation Consideration
- - internal coil and
jacketed vessel - increases pressure drop, decreases
gas flow and provide a pathway for contaminated
cells entry - - mechanical foam breaker
- - surfactant (toxic)
- The working volume is 75 of the total fermenter
volume. - pressurized steam for in-place
sterilization of reactors, seals, probes and
valves. - limited openings.
- - spray balls for clean-in-place