Training manual - PowerPoint PPT Presentation

1 / 96
About This Presentation
Title:

Training manual

Description:

PART : Precise diagnosis for each sensor(Oscilloscope) F6 PART. F3 FRZE. Hi-Scan ... Oscilloscope mode begin as shown in the picture. 1.3 CURRENT DATA - PART ... – PowerPoint PPT presentation

Number of Views:160
Avg rating:5.0/5.0
Slides: 97
Provided by: sungt
Category:

less

Transcript and Presenter's Notes

Title: Training manual


1
(No Transcript)
2
CONTENTS
  • 1. Kia Vehicle Diagnosis
  • 2. Vehicle Scope meter
  • 3. System Setup
  • 4. Optional Items
  • 5. PC-Scan

3
1. Kia Vehicle Diagnosis
  • 1.1 DIAGNOSIS TROUBLE CODE
  • 1.2 FREEZE FRAME DATA
  • 1.3 CURRENT DATA
  • 1.4 MONITERING TEST RESULT
  • 1.5 EVAP. LEAKAGE TEST
  • 1.6 FLIGHT RECORD
  • 1.7 DUAL DISPLAY
  • 1.8 SIMU-SCAN

4
1.1 DIAGNOSIS TROUBLE CODE ( 1/5)
To get started. Following procedures are within
KIA VEHICLE DIAGNOSIS mode
  • On the Hi-Scan Pro keyboard
  • Press ON/OFF button to turn on the Hi-Scan Pro
  • Keep on press Enter button until Initial screen
    come up.
  • Make sure DLC cable is properly connected.
  • FIRST SELECT VEHICLE
  • DIAGNOSIS
  • SECOND SELECT VEHICLE
  • THIRD SELECT SYSTEM
  • FOURTH SELECT VEHICLE
  • YEAR

5
1.1 DIAGNOSIS TROUBLE CODE (2/5)
To view Diagnostic Trouble code.
  • After Selecting the vehicle model year, go
    through the Diagnostic Trouble Code and Current
    data to diagnose the vehicle.
  • If ECM or communication WIRE has problem, Hi-Scan
    Pro cannot communicate with vehicle and display
    the message as shown in picture.

OR
6
1.1 DIAGNOSIS TROUBLE CODE (3/5)
To check Diagnostic Trouble Code
ENTER
  • If ECM has no trouble code with engine system,
    Hi-Scan Pro display on the screen
  • NO TROUBLE CODE
  • If ECM has trouble code with engine system,
    Hi-Scan Pro display
  • TROBLE CODE WITH ITEM

OR
7
1.1 DIAGNOSIS TROUBLE CODE (4/5)
To get information about DTC and delete DTC
  • HELP Basic Major information to help
    understand
  • each trouble code and item
  • ERAS Erase Trouble Code(Follow the
    instruction
  • carefully)


F2 ERAS
F1 HELP
8
1.1 DIAGNOSIS TROUBLE CODE (5/5)
To check the data of sensor with DTC when DTC is
occurred.
  • FREZ Display the data of items with DTC at the
    situation
  • when trouble is occurred.
  • Hi - Scan display FRZE data only when ECM
    support
  • this function.
  • PART Precise diagnosis for each
    sensor(Oscilloscope)

9
1.2 FREEZE FRAME DATA
To check the data of sensor with DTC when DTC is
occurred.

Press ENTER with the cursor on 02. FREEZE
FRAME DATA in 1. KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
10
1.3 CURRENT DATA (1/2)
To view the sensor and actuator data.
Select CURRENT DATA in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
  • FIX Fix current data and display
  • on the top of the screen
  • PART Precise diagnosis for sensor
  • with inverted
    letters(Oscilloscope)
  • FULL Display full 22 items data

F2 PART
F3 FULL
F1 FIX
11
1.3 CURRENT DATA (2/2)
To view the sensor and actuator data.
  • HELP Provide reference data
  • GRPH Waveform graph display
  • RCRD Record sensor data


F6 RCRD
12
  • Connect a probe to CH A of Hi-Scan Pro
  • Go through the appropriate mode and press ENTER
    on 03. CURRENT DATA.
  • Press F2 button to operate PART function.
  • PART Place a box, in which letters are
    inverted, and press PART for precise part
    analysis.
  • Connect a Test Probe to Channel A of Hi-Scan
    Pro.
  • Oscilloscope mode begin as shown in the
    picture.

13
On a CURRENT DATA mode, press F1 to fix the
items and F5 to view the graph.
  • FIX Select the sensors to view GRAPH
  • GRPH Waveform graph display
  • FIX Select the sensors to fix at the top of the
    screen.
  • You can change the sensor by pressing FIX button
    again.
  • You can scroll up and down without moving
    fixed sensor.

14
On a CURRENT DATA mode, press F6 to record a
data.
  • RCRD Move to RECORD mode, in which select
    trigger type.
  • AUTO TRIGGER(ANY DTC) Triggers with any DTC.
  • AUTO TRIGGER(SINGLE DTC) Trigger with single
    user specified DTC.
  • MANUAL TRIGGER User trigger the data recording.
  • FLIGHT RECORD DATA REVIEW Fetch recorded data.

15
After TRIGGER TYPE is chosen, Select memory
location using ?? buttons and press enter.
TYPE ID
  • ENTER Select the memory location then press
    ENTER to type memory ID.
  • Type CAR ID.
  • ENTER Go to DATA RECORD select mode.
  • Select the DATA RECORD type and press
    ENTER.

16
  • ALL DATA RECORD
  • Record all sensor data

17
  • AUTO TRIGGER(SINGLE DTC)
  • Record user defined single DTC.
  • Type specific DTC CODE and
  • press ENTER.
  • Rest of procedures are same as
  • AUTO TRIGGER (ANY DTC)

Type DTC CODE and press ENTER
18
  • MANUAL TRIGGER
  • Place a mark on a recorded data where
    ENTER button
  • is pressed while recording.
  • This mark is displayed as vertical line in
    GRAPH mode.
  • Next procedures are same as AUTO TRIGGER.
  • Select DATA RECORD type.

TYPE ID
19
  • ALL DATA RECORD
  • Record all sensor data
  • ENTER Place a mark on a data where
    ENTER is pressed while
  • recording.

20
  • FLIGHT RECORD DATA REVIEW
  • Review recorded data.
  • Select the memory location, then press ENTER.
  • Press ENTER to review recorded data.

Select the memory location and press ENTER
21
  • GRAP Covert the LIST screen into GRAPH.
  • LIST Covert the GRAPH screen into LIST.
  • HOME Place the triggered position, displayed
    as vertical line, at the middle of the screen.
  • FIX You can scroll up and down without moving
    fixed item. If you press FIX again, you can
    change the item to fix.

F1 GRAP F1 LIST
22
Previous menu

Select MONITORING TEST RESULT in KIA VEHICLE
DIAGNOSIS mode. In this case, connect with
vehicle via DLC cable.
  • MONITORING TEST RESULT
  • This function provides 3 tests,
  • which are
  • 1) READINESS TEST
  • 2) HO2S MONITERING TEST
  • 3) OBD2 MONITERING TEST

ENTER
23
  • READINESS TEST Displays vehicles on-board
    monitoring.
  • Emission-related operations are monitored.
  • Test result accurately reflect vehicles
    condition of emission related components.

24
  • HO2S MONITERING TEST
  • display the results of the Heated Oxygen
    Sensor testing performed by the ECM
  • Hi Scan pro also displays test result by
    converting ECM data.
  • The test result is valid only after ECMs H2OS
    monitoring is finished.

25
  • OBD2 MONITORING TEST
  • User can access to the on-board diagnostic
    monitoring test result of specific component
    /system that are not continuously monitored.
  • List of OBD monitor applicable for RIO
  • - Three-way catalyst converter.
  • - HO2S monitoring.
  • - EVAP. EM monitoring.
  • -Thermostat monitoring.
  • - HO2S heater(B1S1).
  • - HO2S heater(B1S2).
  • - ECT Plausibility.

26
Select EVAP LEAKAGE TEST in KAI VEHICLE
DIAGNOSIS mode. In this case, connect with
vehicle via DLC cable.
  • EVAP. LEAK TEST MODE
  • The EVAP. Leakage Test is based on the
    diagnosis module for tank leakage detection uses
    an electrically driven vane pump.
  • Please follow the Hi-Scan Pro EVAP. LEAKAGE TEST
    process like picture.

DOWN
27
  • NORMAL CONDITION OF EVAP. SYS
  • If evap. Sys of vehicle had being normal,
    Hi-Scan Pro display O.K of the test results.

28
  • ABNORMAL CONDITION OF EVAP. SYS
    If evap.
    Sys of vehicle had being abnormal, Hi-Scan Pro
    display ACTIVATION IS NOT POSSIIBLE.
  • Please check the vehicle condition according to
    Hi-Scan Pro process.


29
  • ABNORMAL CONDITION OF EVAP. SYSIf you retry
    EVAP. Leakage test with-in 5 minutes had finished
    EVAP. Leakage test, Hi-Scan Pro will display NOT
    NECESSRRY.


30
Previous menu

Select FLIGHT RECORD in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle with DLC
cable.
  • ENTER Select the memory location then press
    ENTER to type memory ID.
  • Type CAR ID.
  • ENTER Go to DATA RECORD select mode.
  • Select the DATA RECORD type and press
    ENTER.

ENTER
TYPE ID
31
  • ALL DATA RECORD
  • Record all sensor data

01 ENTER
02 ENTER
32
  • AUTO TRIGGER(SINGLE DTC)
  • Record user defined single DTC.
  • Type specific DTC CODE
  • and press ENTER.
  • Rest of procedures are same as
  • AUTO TRIGGER (ANY DTC)

Type DTC CODE and press ENTER
33
  • MANUAL TRIGGER
  • Place a mark on a recorded data where
  • ENTER button is pressed while recording.
  • This mark is displayed as vertical line in
    GRAPH mode.
  • Next procedures are same as AUTO TRIGGER.
  • Select DATA RECORD type.

Same procedure as AUTO TRIGGER
34
  • ALL DATA RECORD
  • Record all sensor data
  • ENTER Place a mark on a data where
    ENTER is pressed while
  • recording.

35
  • FLIGHT RECORD DATA REVIEW
  • Review recorded data.
  • Select the memory location,
  • then press ENTER.
  • Press ENTER to review recorded data.

Select the memory location and press ENTER
36
  • GRAP Covert the LIST screen into GRAPH.
  • LIST Covert the GRAPH screen into LIST.
  • HOME Place the triggered position, displayed
    as vertical line, at the middle of the screen.
  • FIX You can scroll up and down without moving
    fixed item.
  • If you press FIX again, you can
    change the item to fix.

F1 GRAP F1 LIST
37
Select DUAL DISPLAY in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
  • Hi-Scan Pro can display both DTC and sensor data
    simultaneously.
  • Use can check the sensor data which with DTC.
  • FIX Fix sensor data
  • CURR Activate current data
  • DTC Activate DTC data

38
Previous menu

Select SIMU-SCAM in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable and test probe.
  • METER voltage, frequency, duty, current,
    temperature and pressure meter
  • SIMUL voltage, frequency, duty, simulation

39
  • METER MODE
  • One of the most powerful feature of
    Hi-Scan Pro is SIMU-SCAN, in which sensor output
    data is measured and current data is displayed
    simultaneously that user can compare actual data
    and ECM data.
  • This figure is an example of SIMU-SCAN screen
    for ECT sensor.


PRESS 1 BUTTON ON KEY PAD
40
1.8 SIMU-SCAN (3/4)
PRESS 2 BUTTON ON KEY PAD

PRESS 5 BUTTON ON KEY PAD
  • METER MODE
  • This is an example of SIMU-SCAN screen for
    ISC on time.

41
1.8 SIMU-SCAN (4/4)
To measure the sensor data and compare with scan
data
  • SIMU MODE
  • This is an example of SIMU-SCAN screen for
    TPS sensor with generated voltage 2V.
  • NOTICE
  • SIMU MODE activate on
  • channel B only.

SELECT NUMBER 1 OF KEY PAD

42
2. VEHICLE SCOPEMETER
  • 2.1 Part analysis
  • - Engine 17 items
  • - Auto T/A 9 items
  • 2.2 Manual scope
  • 2.3 Meter(V,F,R,A,T,P)
  • 2.4 Actuator driving
  • 2.5 Sensor simulator

43
2.1 PART ANALYSIS (1/2)
Hi-Scan Pro Application
Analyze part precisely in pre-set oscilloscope
mode
Select VEHICLE SCOPEMETER in INITIAL SCREEN
and select KIA VEHICLE AUTO SCOPE. Connect a
test probe to CH A of Hi-Scan Pro and tap probe
pin into appropriate signal wire of sensor or
actuator.
  • Provides easier component inspection and more
    effective with pre-set DB support and reference
    waveform.
  • KIA VEHICLE AUTO SCOPE
  • Pre-set oscilloscope for KIA vehicles.
  • MANUAL SCOPE Oscilloscope mode.
  • METER Multi-meter mode.
  • ACTUATOR DRIVING
  • Test drive ACTUATOR.
  • SENSOR SIMULATOR
  • Send dummy data to inspect status of sensors.


44
  • ENGINE 17 items.
  • A/T 9 items

45
ENTER
  • Engine sensor mode has 17 pre-set items.
  • User have to connect test probe to CH A, and
    prick probe pin to sensor signal wire.

46
  • CKP SENSOR
  • TIPS Sensor information.
  • WAVE Reference waveform of sensor.
  • AUTO SET DB SUPPORT
  • - Voltage, Time, Trigger Level.

WAVE
ENTER
TIP
47
  • INJECTOR
  • TIPS Actuator Information.
  • WAVE Reference Waveform
  • of sensor.
  • AUTO SET DB SUPPORT
  • Voltage, Time, Trigger Level.

WAVE
TIP
48
  • 1ST IGNATION WAVE
  • WAVE Standard waveform of sensor
  • AUTO SET DB SUPPORT - Voltage, Time, Trigger
    Level.

WAVE
49
  • Automatic Transaxle mode has 9 pre-set items.

50
Select VEHICLE SCOPEMETER in INITIAL SCREEN
and select VEHICLE SCOPEMETER. Connect a test
probe to CH A or CH B of Hi-Scan Pro and tap
into signal wire of sensor or actuator.
ENTER
51
  • 2 Channel digital scope
  • Sampling speed 1MHz / Sec
  • Time division 20? 50S
  • Voltage division 0.5V 50V
  • Adjustable GND level
  • Waveform zoom function (1x, 2x, 5x)
  • Cursor data display

52
  • Selectable data ON / OFF by ?,? KEY
  • Selectable grid line /dot by ?,?KEY
  • Selectable trigger mode by ?,?KEY
  • - MODE Repeat, Single, Auto
  • - SOURCE A?A?B?B?
  • - LEVEL 0 100
  • - DELAY 0 100

53
  • Larger record space - 128KB continuous sampling
  • Video replay view
  • Trend view function (AVERAGE, MIN-MAX,FREQUENCY,
    DUTY)
  • Cursor data display
  • Waveform zoom function (1x, 2x, 5x)

54
  • HOLD Screen hold. Function key will be
    changed after HOLD button is pressed.
  • ZOOM Zoom IN or OUT screen. - X1, X2, X5.
  • CURSOR Display numerical value of waveform.
  • RECORD Record waveform.

55
  • ZOOM
  • User can zoom IN or OUT by pressing ? or
    ? button respectively.
  • User can scroll LEFT to RIGHT by pressing ?
    or ? button respectively.

56
  • CURSOR
  • Cursor is used to display numerical value of
    waveform.
  • Press CURS to display two CURSORS.
  • Move left cursor-straight lined- by pressing ?
    or ? button.
  • Press CURS button again to activate Right
    cursor-dashed line.
  • Cursor will be converted from dash to
    straight.
  • Press CURS button once again, to move both
    cursors together.
  • All the values will be displayed at the top of
    the screen.

57
  • RECORD Records for 1 second
  • FLIGHT RECORD REVIEW
  • Review previously recorded data.
  • NEW FLIGHT RECORD
  • Record new data-New data overwrite on
  • previous record.

58
  • HOLD Screen hold.
  • PLAY Play recorded data.
  • ZOOM Zoom IN or OUT screen.
  • CURS Display numerical value of waveform.
  • VIEW AVERAGE MIN-MAX TREND
  • FREQUENCY DUTY TREND
  • FLIGHT RECORDED WAVEFORM
  • EXIT Return to HOLD mode.

HOLD
59
  • AVERAGE MIN-MAN TREND
  • Display average, minimum, and maximum
  • value of waveform.
  • FREQUENCY DUTY TREND
  • Display frequency and duty of waveform.
  • FLIGHT RECORDED WAVEFORM
  • Return to HOLD mode.
  • Scroll left or right by ? or ? respectively
    and the cursor data is displayed in the box at
    the left.

FLIGHT RECORDED WAVEFORM
AVERAGE MIN-MAX TREND
FREQUENCY DUTY TREND
60
  • NEW FLIGHT RECORD
  • Overwrite new data on previous data.
  • Press any button to start recording.
  • Replay start after recording is finished.

HIT ANY KEY
61
ON
  • DATA
  • ON Following data will be displayed at the top
    of the screen.
  • 1) MIN Minimum Voltage.
  • 2) AVE Average Voltage.
  • 3) MAX Maximum Voltage.
  • 4) FREQ Frequency of Waveform.
  • 5) DUTY Duty cycle of Waveform.
  • OFF DATA will disappear.
  • NOTE If the TIME is set as 20us, DATA
    function will not be supported and only one
    channel is available-Ch A or Ch B due to fast
    sampling load.

OFF
62
  • GRID
  • User can change the GRID from DOT or LINE
    to LINE or DOT respectively.

DOT
LINE
63
  • MODE
  • AUTO Display all the waveform regardless of
    trigger level.
  • REPEAT Screen is refreshed whenever waveform is
    above the trigger level.
  • SINGLE If waveform is above the trigger level,
    the screen will be fixed with triggered waveform.

64
  • SOURCE
  • A?, B?
  • Rising edge of waveform will be displayed at
    the delay level.
  • A?, B?
  • Falling edge of waveform will be displayed
    at the delay level.
  • LEVEL Waveform will be displayed if it is above
    this Trigger level.
  • DELAY Horizontal position of Triggered
    place.

65
Enter after select 3. Meter
Connect a test probe from CH A or CH B, or
both channel and to desired Actuator or Sensor.
  • 2 channel multi meter
  • Volt meter max 500VDC
  • Frequency meter 0 100KHz
  • Duty meter 0 100
  • Ohm meter 0 10?
  • Automatic unit conversion (CURRENT METER /
    TEMPERATUE / PRESSUR METER)

66
Enter after select 4. Actuator
Connect a test probe from CH A and to desired
Actuator.
  • Actuator Driving Mode enables to operate actuator
    forcibly driven by Hi-Scan pro
  • Actuator driving is operated only on CH A.
  • Warning) Do not use this mode when Engine Is
    running
  • DRIV gt Start Driving
  • STOP gt Stop Driving
  • ? ? gt Select the Items
  • ?? gt Chang the Selected Items Level

67
Enter after select 5. Sensor simulator
PREVIOUS MENU
Connect a test probe to CH B and to desired
Sensor.
  • Sensor simulation is operated only on CH B
  • User can simulate a sensor in this mode.
  • VOLT-Simulate a sensor with specific VOLTAGE
  • FREQ-Simulate a sensor with specific FREQUENCY
  • In FREQ mode, user can switch from the
    Frequency to Duty and vice versa by pressing
    SLCT button.
  • In FREQ mode, user can change the value of
    Frequency and Duty using and - button.

68
  • Hold Last Screen gt Determines whether the last
    screen in vehicle diagnosis or oscilloscope mode
    is saved before power shut down
  • Language gtDetermine whether to use Beep sound
    when the buttons are pressed.
  • Language gt Determines whether local language is
    used
  • Unit Conversion gt Selects the measuring units of
    Hi-Scan pro.
  • Self Test gt Determines whether self test is
    performed at each power up

69
Hi-Scan Pro Application
4. OPTIONAL ITEMS
  • 4.1 Current pick up(1A 600A)
  • 4.2 Current pick up(50mA 100A)

70
CURRENT PICK UP (1600A)
  • Compression pressure test
  • Cold cranking ampere test
  • Etc

71
CURRENT PICK UP (1600A)(1/2)
To perform compression pressure test.
  • Connect high current measuring device to CH A or
    B
  • Set to 10mV/A in current level selecting
    switch.
  • Perform zero adjustment.
  • Set as 50ms for time-division and 5V for
    voltage-division.

72
CURRENT PICK UP (1600A)(2/2)
To perform compression pressure test.
  • Clamp the or - terminal of battery with
    current measuring device.
  • Remove ECU fuse.
  • Start cranking for about 2 seconds.
  • Abnormal and normal waveforms are shown
    respectively at the bottom.

When 1st cylinder spark plug is removed
73
CURRENT PICK UP (1600A)(1/2)
To perform cold cranking ampere test.
  • Connect high current measuring device to CH A or
    B
  • Set to 1mV/A in current level selecting switch.
  • Perform zero adjustment.
  • Set as 50ms for time-division and 0.2V for
    voltage-division.

74
CURRENT PICK UP (1600A)(2/2)
To perform cold cranking ampere test.
  • Clamp the or - terminal of battery with
    current measuring device.
  • Remove ECU fuse.
  • Start cranking for about 2 seconds.
  • Example waveform is shown at the bottom right.
  • When testing cranking current, read MAX value for
    current value as shown in bottom right fig.
  • Example) Regard MAX 335,2mV as 335,2A for
    cranking current.
  • Compare with standard value, if it is above 70
    then it is in normal condition.

75
CURRENT PICK UP (50mA100A)
  • Primary ignition current test
  • Actuators current test
  • Etc

76
CURRENT PICK UP (50mA100A)(1/2)
To perform primary ignition current test.
  • Connect low current measuring device to CH A or B
  • Set to proper level in current level selecting
    switch.
  • Perform zero adjustment.
  • Set time-division and voltage-division.

77
CURRENT PICK UP (50mA100A)(2/2)
To perform primary ignition current test.
  • Clamp the primary ignition signal wire with low
    current measuring device.

78
CURRENT PICK UP (50mA100A)
To perform actuators current test.
  • Connect low current measuring device to CH A or B
  • Set to proper level in current level selecting
    switch.
  • Perform zero adjustment.
  • Set time-division and voltage-division in Hi-Scan
    pro.
  • Clamp any actuator you wish to measure with low
    current measuring device.

79
CURRENT PICK UP (50mA100A)(1/2)
To measure parasitic current.
  • Connect low current measuring device to CH A or B
  • In METER screen, select channel and current
    level and press Enter.
  • Select current level as assigned in Hi-Scan Pro.

80
CURRENT PICK UP (50mA100A)(2/2)
To measure parasitic current.
  • Perform zero adjustment.
  • The parasitic current of wire, which is connected
    from battery to 60A fuse in fuse box, is measured
    in Hyundai Accent as shown at the bottom right
    figure.

81
5. PC-SCAN
  • 1) Install PC-Scan
  • 2) SCAN TEST
  • 3) FLIGHT RECORD
  • 4) SCOPE
  • 5) SERVICE INFORMATION
  • 6) SCREEN CAPTURE
  • 7) S/W DOWNLOAD
  • 8) OPTION

82
1) Installation of PC-SCAN program - 1
  • Insert the CD and click Setup file, and then
    follow instruction as
  • shown in figure 15 step by step.


83
Installation of PC-SCAN program - 2

PROGRAM INSTALLING
84
2) SCAN TEST - 1
  • This function is to provide all of the scanning
    tests on your PC. If you press 'SCAN TEST' button
    on the menu, the following "Vehicle Diagnosis"
    screen will be displayed for your vehicle/system
    selection to test firstly.
  • Select the vehicle/system to test in order as
    follows.
  • (1) Select proper vehicle model to test on
  • the upper-left column.
  • (2) Select proper system name to test on
  • the upper-right column
  • (3) Select proper system type on the
  • lower-left column.

85
SCAN TEST- 2(DIAGNOSTICS TROUBLE CODES)
  • If you press DIAGNOSTIC TROUBLE CODES button on
    the pictures Sub Menu screen, the following
    screen will be displayed for DTC testing.
  • ERASE Provides to erase the memorized
  • DTC after repairing
    the
  • troubles clearly.
  • TIP Provides relevant service or
  • repair guides
  • PRINT Provides to print current
  • screen out.
  • HELP Provides relevant user's
  • operation guides on
    the
  • current screen.
  • PREVIOUS Provides to return to the
  • previous menu
    screen

86
SCAN TEST - 3(CURRENT DATA)
  • This function is to provide on-line current
    data analysis of each sensor transferred through
    the ECU. If you press CURRENT DATA button
    on the pictures Sub Menu, the following screen
    will be displayed for Current Data Analysis.
  • Select sensor names(maximum 8 items at once) on
    the sensor item column by clicking the items. To
    cancel its selection, click it again of the
    selected item.
  • TEXT Provides on-line numeric values on the
    selected
  • sensors as picture.
  • PRINT Provides to print current screen out.
  • TIPS Provides diagnostic information for
    service data
  • which selected finally.
  • PREVIOUS Provides to return to the previous
    menu
  • screen.
  • GRAPH Provides to analyze on-line current data
  • values in a graphic
    waveform as below.

87
SCAN TEST - 4 (CURRENT DATA)
  • RECORD Provides to record current graphic data
    in a
  • temporary buffer
    memory on PC.
  • MARKING Provides to indicate location mark
    during
  • data recording.
  • STOP Provides to stop recording
  • REC DATA VIEW Provides to recall a waveform
    data
  • from the recorded
    temporary memory on PC.
  • SAVE Provides to save any waveform data in a
    file form
  • from the temporary memory
    data.
  • PRINT Provides to print out current screen.
  • HELP Provides relevant user's operation guides
    on the
  • current screen.
  • PREVIOUS Provides to return to the previous
    Current
  • Data Main menu
    screen.
  • ZOOM BAR Provides to magnify current screen by
    using
  • the arrow buttons
    up to 10 times.

88
SCAN TEST- 5(ACTUATION TEST)
  • This function mode enables to operate certain
    actuators
  • through communication between ECM and
    Hi-Scan Pro.
  • So, If the ECM does not provide this
    function, you can not
  • use this actuation test mode.
  • Select any actuator item to test on the left
    column and click it on. The test must be
    performed as per the conditions indicated on
    the screen. To cancel the selection, click it on
    again.
  • START Provides to start its testing.
  • PRINT Provides to print current screen out.
  • HELP Provides relevant user's operation
    guides on the
  • current screen.
  • PREVIOUS Provides to return to the previous
    function
  • menu screen.

89
3) FLIGHT RECORD
  • This function is to provide downloading a data to
    your PC from the recorded memory of the Hi-Scan
    Pro, or recalling a data from the PC memory.
  • LIBRARY Provides to recall and refer
    pre-memorized
  • standard sample data
    or waveform.
  • OPEN Provides to open a recorded flight data
    file from PC
  • memory.
  • SAVE Provides to save a flight record data in a
    file form.
  • LOAD Provides to download a flight record data
    from Hi-
  • Scan Pro into your PC.
  • INFORMATION Provides to add user's information
    on the
  • current
    data screen.
  • PRINT Provides to print current screen out.
  • HELP Provides relevant user's operation guides
    on the
  • current screen.
  • PREVIOUS Provides to return to the main menu
    screen.

90
4) SCOPE
  • This function is to provide downloading a scope
    data either from your PC or Hi-Scan Pro memory.
  • LIBRARY Provides to recall pre-memorized
    standard
  • sample scope
    waveforms.
  • OPEN Provides to open a recorded scope waveform
    file
  • from your PC memory.
  • SAVE Provides to save a scope waveform in a
    file form
  • to your PC.
  • LOAD Provides to download a scope waveform from
  • Hi-Scan Pro into your PC.
  • INFORMATION Provides to add user's information
    on
  • the
    current data screen.
  • NOTE Provides to add a personal information
    label on
  • the current data screen
    for detailed explanation.
  • PRINT Provides to print out current screen.
  • HELP Provides relevant user's operation
    guides on
  • the current screen.
  • PREVIOUS Provides to return to the main menu
  • screen.

91
5) SERVICE INFORMATION
  • This mode provides all of the relevant service
    and repair information for each vehicle and
    system in CD-ROM.
  • BACK Provides to return to the previous screen.
  • FORWARD Provides to go to the next screen.
  • E-MAIL Provides to send an E-Mail message to
    the
  • supplier.
  • PRINT Provides to print out the current screen.
  • MAIN Provides to return to the main menu
    screen.
  • Exploring methods and procedures are same as
    those of general Internet Web-browser.
  • Note Be sure to insert relevant CD-ROM
    into your
  • PC driver before using this mode.

92
6) SCREEN CAPTUTE
  • This function is to provide either downloading or
    saving current screen onto your PC.
  • LIBRARY Recall pre-memorized standard sample
    data.
  • OPEN Open a saved screen capture data file from
    your PC hard disk.
  • SAVE Save the captured screen in a file form.
  • LOAD Download current Hi-scan Pro screen onto
    your PC.
  • INFORMATION Add user's information on the
    current data.
  • NOTE Add notes about current data screen for
    personal record.
  • PRINT Print out current screen.
  • HELP Provides relevant user's operation
    guides on the current screen.
  • PREVIOUS Return to main menu screen.
  • TITLE Input title of captured screen.
  • MADE BY Input user's name on the captured
    screen.
  • FILENAME Not accessible by users. It's for
    program designer's purpose. Use SAVE
    button to input its file name.
  • COMMENT Add personal comments.

93
7) S/W DOWNLOAD - 1
  • Get connected
  • Connect your PC and Hi-Scan Pro with
    RS-232C cable

RS232C Cable (Standard Item)
COM1
94
S/W DOWNLOAD - 2
  • After connect RS-232C cable, go to OPTION in
    Pc-scan main screen and assign com port 1 or 2.

Please move cardall.dat file into PcScan.CAB
95
S/W DOWNLOAD - 3
  • Select S/W Download in your PC-Scan Program
    initial screen as shown in below figures.
  • Select cardall.dat file at DB folder which is
    in PcScan.CAB file.

SELECT CARDALL.DAT
  • NOTICE Assign the file(cardall.dat) path
    Select 56000 for Baud Rate Select
    Standard Pack for Data Type

96
8) OPTION
  • This function is to set-up communication speed
    and CD-ROM directory for Service Information
    function.
  • BAUD RATE Select communication speed between
    your PC and Hi-Scan Pro from 9,600 up to 56,000
    bps.
  • SERVICE INFORMATION FOLDER (Main.html) Select
    the location of Main.html
    file.
  • HELP Provides relevant user's operation
    guides on the current screen.
  • OK Confirm selection.
  • CANCEL Cancel selection and return to the
    main menu screen.
Write a Comment
User Comments (0)
About PowerShow.com