Title: Training manual
1(No Transcript)
2CONTENTS
- 1. Kia Vehicle Diagnosis
- 2. Vehicle Scope meter
- 3. System Setup
- 4. Optional Items
- 5. PC-Scan
31. Kia Vehicle Diagnosis
- 1.1 DIAGNOSIS TROUBLE CODE
- 1.2 FREEZE FRAME DATA
- 1.3 CURRENT DATA
- 1.4 MONITERING TEST RESULT
- 1.5 EVAP. LEAKAGE TEST
- 1.6 FLIGHT RECORD
- 1.7 DUAL DISPLAY
- 1.8 SIMU-SCAN
41.1 DIAGNOSIS TROUBLE CODE ( 1/5)
To get started. Following procedures are within
KIA VEHICLE DIAGNOSIS mode
- On the Hi-Scan Pro keyboard
- Press ON/OFF button to turn on the Hi-Scan Pro
- Keep on press Enter button until Initial screen
come up. - Make sure DLC cable is properly connected.
- FIRST SELECT VEHICLE
- DIAGNOSIS
- SECOND SELECT VEHICLE
- THIRD SELECT SYSTEM
- FOURTH SELECT VEHICLE
- YEAR
51.1 DIAGNOSIS TROUBLE CODE (2/5)
To view Diagnostic Trouble code.
- After Selecting the vehicle model year, go
through the Diagnostic Trouble Code and Current
data to diagnose the vehicle. - If ECM or communication WIRE has problem, Hi-Scan
Pro cannot communicate with vehicle and display
the message as shown in picture.
OR
61.1 DIAGNOSIS TROUBLE CODE (3/5)
To check Diagnostic Trouble Code
ENTER
- If ECM has no trouble code with engine system,
Hi-Scan Pro display on the screen - NO TROUBLE CODE
- If ECM has trouble code with engine system,
Hi-Scan Pro display - TROBLE CODE WITH ITEM
OR
71.1 DIAGNOSIS TROUBLE CODE (4/5)
To get information about DTC and delete DTC
- HELP Basic Major information to help
understand - each trouble code and item
- ERAS Erase Trouble Code(Follow the
instruction - carefully)
F2 ERAS
F1 HELP
81.1 DIAGNOSIS TROUBLE CODE (5/5)
To check the data of sensor with DTC when DTC is
occurred.
- FREZ Display the data of items with DTC at the
situation - when trouble is occurred.
- Hi - Scan display FRZE data only when ECM
support - this function.
- PART Precise diagnosis for each
sensor(Oscilloscope)
91.2 FREEZE FRAME DATA
To check the data of sensor with DTC when DTC is
occurred.
Press ENTER with the cursor on 02. FREEZE
FRAME DATA in 1. KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
101.3 CURRENT DATA (1/2)
To view the sensor and actuator data.
Select CURRENT DATA in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
- FIX Fix current data and display
- on the top of the screen
- PART Precise diagnosis for sensor
- with inverted
letters(Oscilloscope) - FULL Display full 22 items data
F2 PART
F3 FULL
F1 FIX
111.3 CURRENT DATA (2/2)
To view the sensor and actuator data.
- HELP Provide reference data
- GRPH Waveform graph display
- RCRD Record sensor data
F6 RCRD
12- Connect a probe to CH A of Hi-Scan Pro
- Go through the appropriate mode and press ENTER
on 03. CURRENT DATA. - Press F2 button to operate PART function.
- PART Place a box, in which letters are
inverted, and press PART for precise part
analysis. - Connect a Test Probe to Channel A of Hi-Scan
Pro. - Oscilloscope mode begin as shown in the
picture.
13On a CURRENT DATA mode, press F1 to fix the
items and F5 to view the graph.
- FIX Select the sensors to view GRAPH
- GRPH Waveform graph display
- FIX Select the sensors to fix at the top of the
screen. - You can change the sensor by pressing FIX button
again. - You can scroll up and down without moving
fixed sensor.
14On a CURRENT DATA mode, press F6 to record a
data.
- RCRD Move to RECORD mode, in which select
trigger type. - AUTO TRIGGER(ANY DTC) Triggers with any DTC.
- AUTO TRIGGER(SINGLE DTC) Trigger with single
user specified DTC. - MANUAL TRIGGER User trigger the data recording.
- FLIGHT RECORD DATA REVIEW Fetch recorded data.
15After TRIGGER TYPE is chosen, Select memory
location using ?? buttons and press enter.
TYPE ID
- ENTER Select the memory location then press
ENTER to type memory ID. - Type CAR ID.
- ENTER Go to DATA RECORD select mode.
- Select the DATA RECORD type and press
ENTER.
16- ALL DATA RECORD
- Record all sensor data
17- AUTO TRIGGER(SINGLE DTC)
- Record user defined single DTC.
- Type specific DTC CODE and
- press ENTER.
- Rest of procedures are same as
- AUTO TRIGGER (ANY DTC)
Type DTC CODE and press ENTER
18- MANUAL TRIGGER
- Place a mark on a recorded data where
ENTER button - is pressed while recording.
- This mark is displayed as vertical line in
GRAPH mode. - Next procedures are same as AUTO TRIGGER.
- Select DATA RECORD type.
TYPE ID
19- ALL DATA RECORD
- Record all sensor data
- ENTER Place a mark on a data where
ENTER is pressed while - recording.
20- FLIGHT RECORD DATA REVIEW
- Review recorded data.
- Select the memory location, then press ENTER.
- Press ENTER to review recorded data.
Select the memory location and press ENTER
21- GRAP Covert the LIST screen into GRAPH.
- LIST Covert the GRAPH screen into LIST.
- HOME Place the triggered position, displayed
as vertical line, at the middle of the screen. - FIX You can scroll up and down without moving
fixed item. If you press FIX again, you can
change the item to fix.
F1 GRAP F1 LIST
22Previous menu
Select MONITORING TEST RESULT in KIA VEHICLE
DIAGNOSIS mode. In this case, connect with
vehicle via DLC cable.
- MONITORING TEST RESULT
- This function provides 3 tests,
- which are
- 1) READINESS TEST
- 2) HO2S MONITERING TEST
- 3) OBD2 MONITERING TEST
ENTER
23- READINESS TEST Displays vehicles on-board
monitoring. - Emission-related operations are monitored.
- Test result accurately reflect vehicles
condition of emission related components.
24- HO2S MONITERING TEST
- display the results of the Heated Oxygen
Sensor testing performed by the ECM - Hi Scan pro also displays test result by
converting ECM data. - The test result is valid only after ECMs H2OS
monitoring is finished.
25- OBD2 MONITORING TEST
- User can access to the on-board diagnostic
monitoring test result of specific component
/system that are not continuously monitored. - List of OBD monitor applicable for RIO
- - Three-way catalyst converter.
- - HO2S monitoring.
- - EVAP. EM monitoring.
- -Thermostat monitoring.
- - HO2S heater(B1S1).
- - HO2S heater(B1S2).
- - ECT Plausibility.
26Select EVAP LEAKAGE TEST in KAI VEHICLE
DIAGNOSIS mode. In this case, connect with
vehicle via DLC cable.
- EVAP. LEAK TEST MODE
- The EVAP. Leakage Test is based on the
diagnosis module for tank leakage detection uses
an electrically driven vane pump. - Please follow the Hi-Scan Pro EVAP. LEAKAGE TEST
process like picture.
DOWN
27 - NORMAL CONDITION OF EVAP. SYS
- If evap. Sys of vehicle had being normal,
Hi-Scan Pro display O.K of the test results.
28- ABNORMAL CONDITION OF EVAP. SYS
If evap.
Sys of vehicle had being abnormal, Hi-Scan Pro
display ACTIVATION IS NOT POSSIIBLE. - Please check the vehicle condition according to
Hi-Scan Pro process.
29- ABNORMAL CONDITION OF EVAP. SYSIf you retry
EVAP. Leakage test with-in 5 minutes had finished
EVAP. Leakage test, Hi-Scan Pro will display NOT
NECESSRRY.
30Previous menu
Select FLIGHT RECORD in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle with DLC
cable.
- ENTER Select the memory location then press
ENTER to type memory ID. - Type CAR ID.
- ENTER Go to DATA RECORD select mode.
- Select the DATA RECORD type and press
ENTER.
ENTER
TYPE ID
31- ALL DATA RECORD
- Record all sensor data
01 ENTER
02 ENTER
32- AUTO TRIGGER(SINGLE DTC)
- Record user defined single DTC.
- Type specific DTC CODE
- and press ENTER.
- Rest of procedures are same as
- AUTO TRIGGER (ANY DTC)
Type DTC CODE and press ENTER
33- MANUAL TRIGGER
- Place a mark on a recorded data where
- ENTER button is pressed while recording.
- This mark is displayed as vertical line in
GRAPH mode. - Next procedures are same as AUTO TRIGGER.
- Select DATA RECORD type.
Same procedure as AUTO TRIGGER
34- ALL DATA RECORD
- Record all sensor data
- ENTER Place a mark on a data where
ENTER is pressed while - recording.
35- FLIGHT RECORD DATA REVIEW
- Review recorded data.
- Select the memory location,
- then press ENTER.
- Press ENTER to review recorded data.
Select the memory location and press ENTER
36- GRAP Covert the LIST screen into GRAPH.
- LIST Covert the GRAPH screen into LIST.
- HOME Place the triggered position, displayed
as vertical line, at the middle of the screen. - FIX You can scroll up and down without moving
fixed item. - If you press FIX again, you can
change the item to fix.
F1 GRAP F1 LIST
37Select DUAL DISPLAY in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable.
- Hi-Scan Pro can display both DTC and sensor data
simultaneously. - Use can check the sensor data which with DTC.
- FIX Fix sensor data
- CURR Activate current data
- DTC Activate DTC data
38Previous menu
Select SIMU-SCAM in KIA VEHICLE DIAGNOSIS
mode. In this case, connect with vehicle via DLC
cable and test probe.
- METER voltage, frequency, duty, current,
temperature and pressure meter - SIMUL voltage, frequency, duty, simulation
39- METER MODE
- One of the most powerful feature of
Hi-Scan Pro is SIMU-SCAN, in which sensor output
data is measured and current data is displayed
simultaneously that user can compare actual data
and ECM data. - This figure is an example of SIMU-SCAN screen
for ECT sensor.
PRESS 1 BUTTON ON KEY PAD
401.8 SIMU-SCAN (3/4)
PRESS 2 BUTTON ON KEY PAD
PRESS 5 BUTTON ON KEY PAD
- METER MODE
- This is an example of SIMU-SCAN screen for
ISC on time.
411.8 SIMU-SCAN (4/4)
To measure the sensor data and compare with scan
data
- SIMU MODE
- This is an example of SIMU-SCAN screen for
TPS sensor with generated voltage 2V. - NOTICE
- SIMU MODE activate on
- channel B only.
SELECT NUMBER 1 OF KEY PAD
422. VEHICLE SCOPEMETER
- 2.1 Part analysis
- - Engine 17 items
- - Auto T/A 9 items
- 2.2 Manual scope
- 2.3 Meter(V,F,R,A,T,P)
- 2.4 Actuator driving
- 2.5 Sensor simulator
43 2.1 PART ANALYSIS (1/2)
Hi-Scan Pro Application
Analyze part precisely in pre-set oscilloscope
mode
Select VEHICLE SCOPEMETER in INITIAL SCREEN
and select KIA VEHICLE AUTO SCOPE. Connect a
test probe to CH A of Hi-Scan Pro and tap probe
pin into appropriate signal wire of sensor or
actuator.
- Provides easier component inspection and more
effective with pre-set DB support and reference
waveform. - KIA VEHICLE AUTO SCOPE
- Pre-set oscilloscope for KIA vehicles.
- MANUAL SCOPE Oscilloscope mode.
- METER Multi-meter mode.
- ACTUATOR DRIVING
- Test drive ACTUATOR.
- SENSOR SIMULATOR
- Send dummy data to inspect status of sensors.
44 - ENGINE 17 items.
- A/T 9 items
45ENTER
- Engine sensor mode has 17 pre-set items.
- User have to connect test probe to CH A, and
prick probe pin to sensor signal wire.
46- CKP SENSOR
- TIPS Sensor information.
- WAVE Reference waveform of sensor.
- AUTO SET DB SUPPORT
- - Voltage, Time, Trigger Level.
WAVE
ENTER
TIP
47 - INJECTOR
- TIPS Actuator Information.
- WAVE Reference Waveform
- of sensor.
- AUTO SET DB SUPPORT
- Voltage, Time, Trigger Level.
WAVE
TIP
48- 1ST IGNATION WAVE
- WAVE Standard waveform of sensor
- AUTO SET DB SUPPORT - Voltage, Time, Trigger
Level.
WAVE
49 - Automatic Transaxle mode has 9 pre-set items.
50Select VEHICLE SCOPEMETER in INITIAL SCREEN
and select VEHICLE SCOPEMETER. Connect a test
probe to CH A or CH B of Hi-Scan Pro and tap
into signal wire of sensor or actuator.
ENTER
51- 2 Channel digital scope
- Sampling speed 1MHz / Sec
- Time division 20? 50S
- Voltage division 0.5V 50V
- Adjustable GND level
- Waveform zoom function (1x, 2x, 5x)
- Cursor data display
52- Selectable data ON / OFF by ?,? KEY
- Selectable grid line /dot by ?,?KEY
- Selectable trigger mode by ?,?KEY
- - MODE Repeat, Single, Auto
- - SOURCE A?A?B?B?
- - LEVEL 0 100
- - DELAY 0 100
53 - Larger record space - 128KB continuous sampling
- Video replay view
- Trend view function (AVERAGE, MIN-MAX,FREQUENCY,
DUTY) - Cursor data display
- Waveform zoom function (1x, 2x, 5x)
54- HOLD Screen hold. Function key will be
changed after HOLD button is pressed. - ZOOM Zoom IN or OUT screen. - X1, X2, X5.
- CURSOR Display numerical value of waveform.
- RECORD Record waveform.
55- ZOOM
- User can zoom IN or OUT by pressing ? or
? button respectively. - User can scroll LEFT to RIGHT by pressing ?
or ? button respectively.
56- CURSOR
- Cursor is used to display numerical value of
waveform. - Press CURS to display two CURSORS.
- Move left cursor-straight lined- by pressing ?
or ? button. - Press CURS button again to activate Right
cursor-dashed line. - Cursor will be converted from dash to
straight. - Press CURS button once again, to move both
cursors together. - All the values will be displayed at the top of
the screen. -
57- RECORD Records for 1 second
- FLIGHT RECORD REVIEW
- Review previously recorded data.
- NEW FLIGHT RECORD
- Record new data-New data overwrite on
- previous record.
58- HOLD Screen hold.
- PLAY Play recorded data.
- ZOOM Zoom IN or OUT screen.
- CURS Display numerical value of waveform.
- VIEW AVERAGE MIN-MAX TREND
- FREQUENCY DUTY TREND
- FLIGHT RECORDED WAVEFORM
- EXIT Return to HOLD mode.
HOLD
59- AVERAGE MIN-MAN TREND
- Display average, minimum, and maximum
- value of waveform.
- FREQUENCY DUTY TREND
- Display frequency and duty of waveform.
- FLIGHT RECORDED WAVEFORM
- Return to HOLD mode.
- Scroll left or right by ? or ? respectively
and the cursor data is displayed in the box at
the left.
FLIGHT RECORDED WAVEFORM
AVERAGE MIN-MAX TREND
FREQUENCY DUTY TREND
60- NEW FLIGHT RECORD
- Overwrite new data on previous data.
- Press any button to start recording.
- Replay start after recording is finished.
HIT ANY KEY
61ON
- DATA
- ON Following data will be displayed at the top
of the screen. - 1) MIN Minimum Voltage.
- 2) AVE Average Voltage.
- 3) MAX Maximum Voltage.
- 4) FREQ Frequency of Waveform.
- 5) DUTY Duty cycle of Waveform.
- OFF DATA will disappear.
- NOTE If the TIME is set as 20us, DATA
function will not be supported and only one
channel is available-Ch A or Ch B due to fast
sampling load.
OFF
62- GRID
- User can change the GRID from DOT or LINE
to LINE or DOT respectively.
DOT
LINE
63- MODE
- AUTO Display all the waveform regardless of
trigger level. - REPEAT Screen is refreshed whenever waveform is
above the trigger level. - SINGLE If waveform is above the trigger level,
the screen will be fixed with triggered waveform.
64- SOURCE
- A?, B?
- Rising edge of waveform will be displayed at
the delay level. - A?, B?
- Falling edge of waveform will be displayed
at the delay level. - LEVEL Waveform will be displayed if it is above
this Trigger level. - DELAY Horizontal position of Triggered
place.
65Enter after select 3. Meter
Connect a test probe from CH A or CH B, or
both channel and to desired Actuator or Sensor.
- 2 channel multi meter
- Volt meter max 500VDC
- Frequency meter 0 100KHz
- Duty meter 0 100
- Ohm meter 0 10?
- Automatic unit conversion (CURRENT METER /
TEMPERATUE / PRESSUR METER)
66Enter after select 4. Actuator
Connect a test probe from CH A and to desired
Actuator.
- Actuator Driving Mode enables to operate actuator
forcibly driven by Hi-Scan pro - Actuator driving is operated only on CH A.
- Warning) Do not use this mode when Engine Is
running - DRIV gt Start Driving
- STOP gt Stop Driving
- ? ? gt Select the Items
- ?? gt Chang the Selected Items Level
67Enter after select 5. Sensor simulator
PREVIOUS MENU
Connect a test probe to CH B and to desired
Sensor.
- Sensor simulation is operated only on CH B
- User can simulate a sensor in this mode.
- VOLT-Simulate a sensor with specific VOLTAGE
- FREQ-Simulate a sensor with specific FREQUENCY
- In FREQ mode, user can switch from the
Frequency to Duty and vice versa by pressing
SLCT button. - In FREQ mode, user can change the value of
Frequency and Duty using and - button.
68- Hold Last Screen gt Determines whether the last
screen in vehicle diagnosis or oscilloscope mode
is saved before power shut down - Language gtDetermine whether to use Beep sound
when the buttons are pressed. - Language gt Determines whether local language is
used - Unit Conversion gt Selects the measuring units of
Hi-Scan pro. - Self Test gt Determines whether self test is
performed at each power up
69Hi-Scan Pro Application
4. OPTIONAL ITEMS
- 4.1 Current pick up(1A 600A)
- 4.2 Current pick up(50mA 100A)
70CURRENT PICK UP (1600A)
- Compression pressure test
- Cold cranking ampere test
- Etc
71CURRENT PICK UP (1600A)(1/2)
To perform compression pressure test.
- Connect high current measuring device to CH A or
B - Set to 10mV/A in current level selecting
switch. - Perform zero adjustment.
- Set as 50ms for time-division and 5V for
voltage-division.
72CURRENT PICK UP (1600A)(2/2)
To perform compression pressure test.
- Clamp the or - terminal of battery with
current measuring device. - Remove ECU fuse.
- Start cranking for about 2 seconds.
- Abnormal and normal waveforms are shown
respectively at the bottom.
When 1st cylinder spark plug is removed
73CURRENT PICK UP (1600A)(1/2)
To perform cold cranking ampere test.
- Connect high current measuring device to CH A or
B - Set to 1mV/A in current level selecting switch.
- Perform zero adjustment.
- Set as 50ms for time-division and 0.2V for
voltage-division.
74CURRENT PICK UP (1600A)(2/2)
To perform cold cranking ampere test.
- Clamp the or - terminal of battery with
current measuring device. - Remove ECU fuse.
- Start cranking for about 2 seconds.
- Example waveform is shown at the bottom right.
- When testing cranking current, read MAX value for
current value as shown in bottom right fig. - Example) Regard MAX 335,2mV as 335,2A for
cranking current. - Compare with standard value, if it is above 70
then it is in normal condition.
75CURRENT PICK UP (50mA100A)
- Primary ignition current test
- Actuators current test
- Etc
76CURRENT PICK UP (50mA100A)(1/2)
To perform primary ignition current test.
- Connect low current measuring device to CH A or B
- Set to proper level in current level selecting
switch. - Perform zero adjustment.
- Set time-division and voltage-division.
77CURRENT PICK UP (50mA100A)(2/2)
To perform primary ignition current test.
- Clamp the primary ignition signal wire with low
current measuring device.
78CURRENT PICK UP (50mA100A)
To perform actuators current test.
- Connect low current measuring device to CH A or B
- Set to proper level in current level selecting
switch. - Perform zero adjustment.
- Set time-division and voltage-division in Hi-Scan
pro. - Clamp any actuator you wish to measure with low
current measuring device.
79CURRENT PICK UP (50mA100A)(1/2)
To measure parasitic current.
- Connect low current measuring device to CH A or B
- In METER screen, select channel and current
level and press Enter. - Select current level as assigned in Hi-Scan Pro.
80CURRENT PICK UP (50mA100A)(2/2)
To measure parasitic current.
- Perform zero adjustment.
- The parasitic current of wire, which is connected
from battery to 60A fuse in fuse box, is measured
in Hyundai Accent as shown at the bottom right
figure.
815. PC-SCAN
- 1) Install PC-Scan
- 2) SCAN TEST
- 3) FLIGHT RECORD
- 4) SCOPE
- 5) SERVICE INFORMATION
- 6) SCREEN CAPTURE
- 7) S/W DOWNLOAD
- 8) OPTION
82 1) Installation of PC-SCAN program - 1
- Insert the CD and click Setup file, and then
follow instruction as - shown in figure 15 step by step.
83 Installation of PC-SCAN program - 2
PROGRAM INSTALLING
84 2) SCAN TEST - 1
- This function is to provide all of the scanning
tests on your PC. If you press 'SCAN TEST' button
on the menu, the following "Vehicle Diagnosis"
screen will be displayed for your vehicle/system
selection to test firstly. - Select the vehicle/system to test in order as
follows. - (1) Select proper vehicle model to test on
- the upper-left column.
- (2) Select proper system name to test on
- the upper-right column
- (3) Select proper system type on the
- lower-left column.
85SCAN TEST- 2(DIAGNOSTICS TROUBLE CODES)
- If you press DIAGNOSTIC TROUBLE CODES button on
the pictures Sub Menu screen, the following
screen will be displayed for DTC testing. - ERASE Provides to erase the memorized
- DTC after repairing
the - troubles clearly.
- TIP Provides relevant service or
- repair guides
- PRINT Provides to print current
- screen out.
- HELP Provides relevant user's
- operation guides on
the - current screen.
- PREVIOUS Provides to return to the
- previous menu
screen
86SCAN TEST - 3(CURRENT DATA)
- This function is to provide on-line current
data analysis of each sensor transferred through
the ECU. If you press CURRENT DATA button
on the pictures Sub Menu, the following screen
will be displayed for Current Data Analysis.
- Select sensor names(maximum 8 items at once) on
the sensor item column by clicking the items. To
cancel its selection, click it again of the
selected item. - TEXT Provides on-line numeric values on the
selected - sensors as picture.
- PRINT Provides to print current screen out.
- TIPS Provides diagnostic information for
service data - which selected finally.
- PREVIOUS Provides to return to the previous
menu - screen.
- GRAPH Provides to analyze on-line current data
- values in a graphic
waveform as below. -
87SCAN TEST - 4 (CURRENT DATA)
- RECORD Provides to record current graphic data
in a - temporary buffer
memory on PC. - MARKING Provides to indicate location mark
during - data recording.
- STOP Provides to stop recording
- REC DATA VIEW Provides to recall a waveform
data - from the recorded
temporary memory on PC. - SAVE Provides to save any waveform data in a
file form - from the temporary memory
data. - PRINT Provides to print out current screen.
- HELP Provides relevant user's operation guides
on the - current screen.
- PREVIOUS Provides to return to the previous
Current - Data Main menu
screen. - ZOOM BAR Provides to magnify current screen by
using - the arrow buttons
up to 10 times. -
88SCAN TEST- 5(ACTUATION TEST)
- This function mode enables to operate certain
actuators - through communication between ECM and
Hi-Scan Pro. - So, If the ECM does not provide this
function, you can not - use this actuation test mode.
- Select any actuator item to test on the left
column and click it on. The test must be
performed as per the conditions indicated on
the screen. To cancel the selection, click it on
again. - START Provides to start its testing.
- PRINT Provides to print current screen out.
- HELP Provides relevant user's operation
guides on the - current screen.
- PREVIOUS Provides to return to the previous
function - menu screen.
893) FLIGHT RECORD
- This function is to provide downloading a data to
your PC from the recorded memory of the Hi-Scan
Pro, or recalling a data from the PC memory. - LIBRARY Provides to recall and refer
pre-memorized - standard sample data
or waveform. - OPEN Provides to open a recorded flight data
file from PC - memory.
- SAVE Provides to save a flight record data in a
file form. - LOAD Provides to download a flight record data
from Hi- - Scan Pro into your PC.
- INFORMATION Provides to add user's information
on the - current
data screen. - PRINT Provides to print current screen out.
- HELP Provides relevant user's operation guides
on the - current screen.
- PREVIOUS Provides to return to the main menu
screen.
904) SCOPE
- This function is to provide downloading a scope
data either from your PC or Hi-Scan Pro memory. - LIBRARY Provides to recall pre-memorized
standard - sample scope
waveforms. - OPEN Provides to open a recorded scope waveform
file - from your PC memory.
- SAVE Provides to save a scope waveform in a
file form - to your PC.
- LOAD Provides to download a scope waveform from
- Hi-Scan Pro into your PC.
- INFORMATION Provides to add user's information
on - the
current data screen. - NOTE Provides to add a personal information
label on - the current data screen
for detailed explanation. - PRINT Provides to print out current screen.
- HELP Provides relevant user's operation
guides on - the current screen.
- PREVIOUS Provides to return to the main menu
- screen.
915) SERVICE INFORMATION
- This mode provides all of the relevant service
and repair information for each vehicle and
system in CD-ROM. - BACK Provides to return to the previous screen.
- FORWARD Provides to go to the next screen.
- E-MAIL Provides to send an E-Mail message to
the - supplier.
- PRINT Provides to print out the current screen.
- MAIN Provides to return to the main menu
screen. -
- Exploring methods and procedures are same as
those of general Internet Web-browser. - Note Be sure to insert relevant CD-ROM
into your - PC driver before using this mode.
926) SCREEN CAPTUTE
- This function is to provide either downloading or
saving current screen onto your PC. - LIBRARY Recall pre-memorized standard sample
data. - OPEN Open a saved screen capture data file from
your PC hard disk. - SAVE Save the captured screen in a file form.
- LOAD Download current Hi-scan Pro screen onto
your PC. - INFORMATION Add user's information on the
current data. - NOTE Add notes about current data screen for
personal record. - PRINT Print out current screen.
- HELP Provides relevant user's operation
guides on the current screen. - PREVIOUS Return to main menu screen.
- TITLE Input title of captured screen.
- MADE BY Input user's name on the captured
screen. - FILENAME Not accessible by users. It's for
program designer's purpose. Use SAVE
button to input its file name. - COMMENT Add personal comments.
937) S/W DOWNLOAD - 1
- Get connected
- Connect your PC and Hi-Scan Pro with
RS-232C cable
RS232C Cable (Standard Item)
COM1
94S/W DOWNLOAD - 2
- After connect RS-232C cable, go to OPTION in
Pc-scan main screen and assign com port 1 or 2.
Please move cardall.dat file into PcScan.CAB
95S/W DOWNLOAD - 3
- Select S/W Download in your PC-Scan Program
initial screen as shown in below figures. - Select cardall.dat file at DB folder which is
in PcScan.CAB file.
SELECT CARDALL.DAT
- NOTICE Assign the file(cardall.dat) path
Select 56000 for Baud Rate Select
Standard Pack for Data Type
968) OPTION
- This function is to set-up communication speed
and CD-ROM directory for Service Information
function. - BAUD RATE Select communication speed between
your PC and Hi-Scan Pro from 9,600 up to 56,000
bps. - SERVICE INFORMATION FOLDER (Main.html) Select
the location of Main.html
file. - HELP Provides relevant user's operation
guides on the current screen. - OK Confirm selection.
- CANCEL Cancel selection and return to the
main menu screen.